Caoxin Yan1, Xiaofeng Bao1, Weihui Shentu1, Jian Chen2, Chunmei Liu1, Qin Ye3, Liuhong Wang4, Yangbin Tan4, Pintong Huang5.
Abstract
The aim of this study was to compare the accuracy of multi-detector computed tomography (MDCT) with double contrast-enhanced ultrasound (DCEUS), in which intravenous microbubbles are used alongside oral contrast-enhanced ultrasound, in determining the gross classification of patients with gastric carcinoma (GC). Altogether, 239 patients with GC proved by histology after endoscopic biopsy were included in this study. DCEUS and MDCT were performed pre-operatively. The diagnostic accuracies of DCEUS and MDCT in determining the gross classification were calculated and compared. The overall accuracy of DCEUS in determining the gross appearance of GC was higher than that of MDCT (84.9% vs. 79.9%, p < 0.001). There was no significant difference in accuracy between DCEUS and MDCT for Borrmann I and IV classifications of advanced gastric cancer (χ(2), p = 0.323 for Borrmann type I, p = 0.141 for Borrmann type IV). The accuracy of DCEUS for early GC and Borrmann II and III classifications of GC was higher than that of MDCT (χ(2), p = 0.000 for all). DCEUS may be regarded as a valuable complementary tool to MDCT in determining the gross appearance of gastric adenocarcinoma pre-operatively.Entities:
Keywords: Borrmann classification; Computed tomography; Contrast; Gastric neoplasms; Microbubbles; Ultrasonography
Mesh:
Substances:
Year: 2016 PMID: 27072076 DOI: 10.1016/j.ultrasmedbio.2016.01.030