BACKGROUND: Posterior humeral decentering presents a challenge in glenohumeral arthroplasty. Soft tissue releases and osteophyte resection can lead to intraoperative decentering not evident preoperatively. Inferior outcomes result if decentering is not addressed as a part of the arthroplasty. When there is >50% posterior subluxation of the humeral head on passive elevation of the arm at surgery, we have used an anteriorly eccentric humeral head component to improve centering of the humeral articular surface on the glenoid. METHODS: We reviewed the 2-year outcomes for 33 shoulder arthroplasties in which anteriorly eccentric humeral heads were used to manage posterior decentering identified at surgery. Rotator interval plication was performed in 16 cases as an adjunctive stabilizing procedure. Shoulders were evaluated preoperatively and postoperatively with the Simple Shoulder Test (SST). Radiographic centering was characterized before surgery and at follow-up on standardized axillary radiographs with the arm held in a position of functional elevation. RESULTS: With the anteriorly eccentric head component, preoperative radiographic humeral decentering was reduced from 10.4% ± 7.9% to 0.9% ± 2.3% postoperatively (P < .001). SST scores improved from 4.8 ± 2.3 to 10.0 ± 2.3 (P < .001). Preoperative posterior humeral head decentering did not correlate with preoperative glenoid version. Glenoid retroversion was 19.8° ± 8.9° preoperatively and 15.5° ± 7.5° postoperatively. CONCLUSIONS: Posterior decentering identified at surgery when standard trial components are in place can be addressed by replacing the anatomic humeral head with an anteriorly eccentric humeral head component.
BACKGROUND: Posterior humeral decentering presents a challenge in glenohumeral arthroplasty. Soft tissue releases and osteophyte resection can lead to intraoperative decentering not evident preoperatively. Inferior outcomes result if decentering is not addressed as a part of the arthroplasty. When there is >50% posterior subluxation of the humeral head on passive elevation of the arm at surgery, we have used an anteriorly eccentric humeral head component to improve centering of the humeral articular surface on the glenoid. METHODS: We reviewed the 2-year outcomes for 33 shoulder arthroplasties in which anteriorly eccentric humeral heads were used to manage posterior decentering identified at surgery. Rotator interval plication was performed in 16 cases as an adjunctive stabilizing procedure. Shoulders were evaluated preoperatively and postoperatively with the Simple Shoulder Test (SST). Radiographic centering was characterized before surgery and at follow-up on standardized axillary radiographs with the arm held in a position of functional elevation. RESULTS: With the anteriorly eccentric head component, preoperative radiographic humeral decentering was reduced from 10.4% ± 7.9% to 0.9% ± 2.3% postoperatively (P < .001). SST scores improved from 4.8 ± 2.3 to 10.0 ± 2.3 (P < .001). Preoperative posterior humeral head decentering did not correlate with preoperative glenoid version. Glenoid retroversion was 19.8° ± 8.9° preoperatively and 15.5° ± 7.5° postoperatively. CONCLUSIONS: Posterior decentering identified at surgery when standard trial components are in place can be addressed by replacing the anatomic humeral head with an anteriorly eccentric humeral head component.
Authors: Benjamin C Service; Jason E Hsu; Jeremy S Somerson; Stacy M Russ; Frederick A Matsen Journal: Clin Orthop Relat Res Date: 2017-07-05 Impact factor: 4.176
Authors: Frederick A Matsen; Anastasia Whitson; Sarah E Jackins; Moni B Neradilek; Winston J Warme; Jason E Hsu Journal: Int Orthop Date: 2019-06-25 Impact factor: 3.075
Authors: Frederick A Matsen; Stacy M Russ; Phuong T Vu; Jason E Hsu; Robert M Lucas; Bryan A Comstock Journal: Clin Orthop Relat Res Date: 2016-07-25 Impact factor: 4.176
Authors: Aaron M Chamberlain; Nathan Orvets; Brendan Patterson; Peter Chalmers; Michelle Gosselin; Dane Salazar; Jay D Keener Journal: JSES Int Date: 2020-06-17