Literature DB >> 27067753

Acetabular Cup Anteversion and Inclination in Hip Range of Motion to Impingement.

Thomas F McCarthy1, Vincent Alipit1, Jim Nevelos1, Randa K Elmallah2, Michael A Mont2.   

Abstract

BACKGROUND: It is advocated that to avoid complications associated with femoral stem impingement, acetabular positioning should be within a "safe zone." However, instability remains prevalent despite accurate cup positioning, with studies showing dislocations of cups despite positioning within safe zones. We assessed cup position angles associated with impingement in a group of subjects during (1) squatting; (2) object pick-up; and (3) low chair rise.
METHODS: Ten subjects (mean age, 69 years; body mass index, 28.4 kg/m(2)) performed object pick up, squatting, and low-chair rising. Femur-to-pelvis relative motions were recorded for flexion/extension, abduction/adduction, and internal/external rotation. A previously reported custom-validated hip range-of-motion 3-dimensional simulator was used, set for neutral pelvic tilt and 15(°) of stem version. Acetabular cup abduction and anteversion combinations were chosen. The software computed minimum clearances between components for any hip position. An idealized tapered wedge stem with a 132° neck angle and a 36-mm femoral head was used.
RESULTS: Eight subjects had impingement on squatting between 21(°) and 51(°) of inclination. During object pick-up, 9 subjects had impingement with inclination and anteversion angles within the "safe zone." In low-chair rise, 8 subjects had impingement at cup inclination angles between 14.5(°) and 49.5(°).
CONCLUSION: The true acetabular target for impingement-avoidance motion is much smaller than previously believed and varies considerably between patients. Certain activities, such as picking up an object, low-chair rise, and squatting reduce the size of the safe zone. This study supports the need for better individualized preoperative patient-specific planning and intraoperative execution for placement of the components.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  acetabular cup; anteversion; impingement; inclination; safe zone; total hip arthroplasty

Mesh:

Year:  2016        PMID: 27067753     DOI: 10.1016/j.arth.2016.01.067

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  16 in total

1.  Accuracy of plain antero-posterior radiographic-based methods for measurement of acetabular cup version.

Authors:  Mohammad Ali Alzohiry; Mohammad Kamal Abdelnasser; Mohamed Moustafa; Mohamed Mahran; Hatem Bakr; Yaser Khalifa; Ahmed Abelaal; Haisam Atta; Galal Zaki Said
Journal:  Int Orthop       Date:  2018-06-04       Impact factor: 3.075

2.  The Safe Zone Range for Cup Anteversion Is Narrower Than for Inclination in THA.

Authors:  William S Murphy; Ho Hyun Yun; Brett Hayden; Jens H Kowal; Stephen B Murphy
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

Review 3.  Sagittal Pelvic Kinematics in Hip Arthroplasty.

Authors:  Thomas E Niemeier; Brad W Wills; Steven M Theiss; Shane F Strom
Journal:  Curr Rev Musculoskelet Med       Date:  2020-06

4.  Comparison of a Minimally Invasive Tissue-Sparing Posterior Superior (TSPS) Approach and the Standard Posterior Approach for Hip Replacement.

Authors:  Matteo Romagnoli; Federico Raggi; Tommaso Roberti di Sarsina; Alvise Saracco; Marco Casali; Alberto Grassi; Stefano Zaffagnini
Journal:  Biomed Res Int       Date:  2022-06-30       Impact factor: 3.246

Review 5.  Hip-spine relationship in total hip arthroplasty - Simplifying the concepts.

Authors:  Sahil Batra; Tarun Khare; Apoorva Praveen Kabra; Rajesh Malhotra
Journal:  J Clin Orthop Trauma       Date:  2022-04-22

6.  Personalized Cup Positioning Guides Improved Cup Positioning and Hip Ranges of Motion in Robotic Assisted Total Hip Arthroplasty.

Authors:  Ruoyu Wang; Xiaojing Zheng; Tianze Xu; Song Gong; Shaokai Liu; Lizhi Han; Shuhua Yang; Weihua Xu
Journal:  Front Bioeng Biotechnol       Date:  2020-08-21

7.  Kinematic alignment technique for total hip and knee arthroplasty: The personalized implant positioning surgery.

Authors:  Charles Rivière; Stefan Lazic; Loïc Villet; Yann Wiart; Sarah Muirhead Allwood; Justin Cobb
Journal:  EFORT Open Rev       Date:  2018-03-29

8.  Spine-hip relations in patients with hip osteoarthritis.

Authors:  Charles Rivière; Stefan Lazic; Louis Dagneaux; Catherine Van Der Straeten; Justin Cobb; Sarah Muirhead-Allwood
Journal:  EFORT Open Rev       Date:  2018-02-21

9.  Digitalized analyses of intraoperative acetabular component position using image-matching technique in total hip arthroplasty.

Authors:  Shinya Kawahara; Toshihiko Hara; Taishi Sato; Kazuki Kitade; Takeshi Shimoto; Tetsuro Nakamura; Taro Mawatari; Hidehiko Higaki; Yasuharu Nakashima
Journal:  Bone Joint Res       Date:  2020-07-23       Impact factor: 5.853

10.  An accelerometer-based navigation system provides acetabular cup orientation accuracy comparable to that of computed tomography-based navigation during total hip arthroplasty in the supine position.

Authors:  Tomonori Tetsunaga; Kazuki Yamada; Tomoko Tetsunaga; Tomoaki Sanki; Yoshi Kawamura; Toshifumi Ozaki
Journal:  J Orthop Surg Res       Date:  2020-04-15       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.