Literature DB >> 27067171

All-Polyethylene Tibial Components: An Analysis of Long-Term Outcomes and Infection.

Matthew T Houdek1, Eric R Wagner1, Cody C Wyles2, Chad D Watts1, Joseph R Cass1, Robert T Trousdale1.   

Abstract

BACKGROUND: There is debate regarding tibial component modularity and composition in total knee arthroplasty (TKA). Biomechanical studies have suggested improved stress distribution in metal-backed tibias; however, these results have not translated clinically. The purpose of this study was to analyze the outcomes of all-polyethylene components and to compare the results to those with metal-backed components.
METHODS: We reviewed 31,939 patients undergoing a primary TKA over a 43-year period (1970-2013). There were 28,224 (88%) metal-backed and 3715 (12%) all-polyethylene tibial components. The metal-backed and all-polyethylene groups had comparable demographics with respect to gender, age and body mass index (BMI). Mean follow-up was 7 years.
RESULTS: The mean survival for all primary TKAs at the 5-, 10-, 20- and 30-year time points was 95%, 89%, 73%, and 57%, respectively. All-polyethylene tibial components were found to have a significantly improved (P < .0001) survivorship when compared with their metal-backed counterparts. All-polyethylene tibial components were also found to have a significantly lower rate of infection, instability, tibial component loosening, and periprosthetic fracture. The all-polyethylene group had improved survival rates in all age groups, except in patients 85 years old or greater, where there was no significant difference. All-polyethylene tibial components had improved survival for all BMI groups except in the morbidly obese (BMI ≥ 40) where there was no significant difference.
CONCLUSION: All-polyethylene tibial components had significantly improved implant survival, reduced rates of postoperative infection, fracture, and tibial component loosening. All polyethylene should be considered for most of the patients, regardless of age and BMI.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  all-polyethylene tibia; infection; metal backed; outcome; total knee arthroplasty

Mesh:

Substances:

Year:  2016        PMID: 27067171     DOI: 10.1016/j.arth.2015.12.048

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  2 in total

1.  All-polyethylene tibial components in distal femur limb-salvage surgery: a finite element analysis based on promising clinical outcomes.

Authors:  Fan Tang; Yong Zhou; Wenli Zhang; Li Min; Rui Shi; Yi Luo; Hong Duan; Chongqi Tu
Journal:  J Orthop Surg Res       Date:  2017-04-04       Impact factor: 2.359

2.  Late stabilization after initial migration in patients undergoing cemented total knee arthroplasty: a 5-year followup of 2 randomized controlled trials using radiostereometric analysis.

Authors:  Shaho Hasan; Bart L Kaptein; Perla J Marang-van de Mheen; Koen T Van Hamersveld; Rob G H H Nelissen; Sören Toksvig-Larsen
Journal:  Acta Orthop       Date:  2022-01-24       Impact factor: 3.717

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.