| Literature DB >> 27064999 |
Hae Woong Jeong1, Sung-Chul Jin2.
Abstract
OBJECTIVE: Based on the use of Nano™ coils, we retrospectively compared the proportion of the coils (≤ 1.5 mm) and packing density in two patient groups with small cerebral aneurysms (< 4 mm diameter) who were treated with or without Nano™ coils.Entities:
Keywords: Cerebral aneurysm; Endovascular
Year: 2015 PMID: 27064999 PMCID: PMC4823426 DOI: 10.7461/jcen.2015.17.4.295
Source DB: PubMed Journal: J Cerebrovasc Endovasc Neurosurg ISSN: 2234-8565
Comparison of demographic and radiological data between small cerebral aneurysms treated with Nano™ coils and without Nano™ coils
| Without NanoTM coils (n = 103) | With NanoTM coils (n = 45) | ||
|---|---|---|---|
| Age | 57.4 ± 10.4 | 54.9 ± 11.6 | 0.209 |
| Rupture | 0.065 | ||
| Yes | 6 | 7 | |
| No | 97 | 38 | |
| Aneurysm location | 0.428 | ||
| Pericallosal | 1 | 0 | |
| ACoA | 17 | 6 | |
| A1 | 0 | 1 | |
| MCA bifurcation | 8 | 3 | |
| M1 | 3 | 2 | |
| ICA bifurcation | 1 | 2 | |
| AchA | 6 | 3 | |
| PCoA | 11 | 7 | |
| Dorsal wall | 1 | 2 | |
| Paraclinoid | 48 | 15 | |
| Basilar trunk | 2 | 0 | |
| PICA | 1 | 1 | |
| SCA | 2 | 0 | |
| Basilar bifurcation | 1 | 2 | |
| P1 | 1 | 1 | |
| Aneurysm height (mm) | 2.86 ± 0.49 | 2.88 ± 0.50 | 0.841 |
| Aneurysm width (mm) | 2.92 ± 0.54 | 2.84 ± 0.57 | 0.449 |
| Aneurysm neck (mm) | 2.64 ± 0.63 | 2.64 ± 0.64 | 0.981 |
| Aneurysm depth (mm) | 2.84 ± 0.53 | 2.87 ± 0.65 | 0.772 |
| Aneurysm volume (mL) | 0.129 ± 0.005 | 0.128 ± 0.005 | 0.912 |
ACoA = anterior communicating artery; A1 = proximal anterior cerebral artery; MCA = middle cerebral artery; M1 = proximal middle cerebral artery; ICA = internal carotid artery; AchA = anterior choroidal artery; PCoA = posterior communicating artery; PICA = posterior inferior cerebellar artery; SCA = superior cerebellar artery; P1 = proximal posterior cerebral artery
Comparison of packing density, procedure modality, radiological outcomes, and procedural complications between small cerebral aneurysms treated with Nano™ coils and without Nano™ coils
| Without NanoTM coils (n = 103) | With NanoTM coils (n = 45) | ||
|---|---|---|---|
| No. of coils | 2.37 ± 1.17 | 2.87 ± 1.29 | 0.023 |
| Coil length (cm) | 7.33 ± 3.52 | 7.67 ± 3.78 | 0.612 |
| Coil volume (mL) | 0.039 ± 0.017 | 0.041 ± 0.002 | 0.553 |
| Proportion of coil ≤ 1.5 mm (%) | 14.7 ± 25.2 | 53.6 ± 28.7 | < 0.001 |
| Packing density | 29.49 ± 7.84 | 31.3 ± 9.69 | 0.228 |
| Coiling technique | 0.106 | ||
| Simple | 45 | 23 | |
| Stent-assisted | 48 | 21 | |
| Double | 9 | 1 | |
| Wire-assisted | 1 | 0 | |
| Radiological outcomes | 0.190 | ||
| Partial | 16 | 4 | |
| Residual neck | 18 | 8 | |
| Complete | 69 | 33 | |
| Procedural complications | 0.666 | ||
| Thromboembolism (symptomatic thromboembolism) | 1 (1) | 1 (0) | |
| ICA dissection | 1 | 0 |
ICA = internal carotid artery