Literature DB >> 27064508

Powered exoskeletons for bipedal locomotion after spinal cord injury.

Jose L Contreras-Vidal1, Nikunj A Bhagat, Justin Brantley, Jesus G Cruz-Garza, Yongtian He, Quinn Manley, Sho Nakagome, Kevin Nathan, Su H Tan, Fangshi Zhu, Jose L Pons.   

Abstract

OBJECTIVE: Powered exoskeletons promise to increase the quality of life of people with lower-body paralysis or weakened legs by assisting or restoring legged mobility while providing health benefits across multiple physiological systems. Here, a systematic review of the literature on powered exoskeletons addressed critical questions: What is the current evidence of clinical efficacy for lower-limb powered exoskeletons? What are the benefits and risks for individuals with spinal cord injury (SCI)? What are the levels of injury considered in such studies? What are their outcome measures? What are the opportunities for the next generation exoskeletons? APPROACH: A systematic search of online databases was performed to identify clinical trials and safety or efficacy studies with lower-limb powered exoskeletons for individuals with SCI. Twenty-two studies with eight powered exoskeletons thus selected, were analyzed based on the protocol design, subject demographics, study duration, and primary/secondary outcome measures for assessing exoskeleton's performance in SCI subjects. MAIN
RESULTS: Findings show that the level of injury varies across studies, with T10 injuries being represented in 45.4% of the studies. A categorical breakdown of outcome measures revealed 63% of these measures were gait and ambulation related, followed by energy expenditure (16%), physiological improvements (13%), and usability and comfort (8%). Moreover, outcome measures varied across studies, and none had measures spanning every category, making comparisons difficult. SIGNIFICANCE: This review of the literature shows that a majority of current studies focus on thoracic level injury as well as there is an emphasis on ambulatory-related primary outcome measures. Future research should: 1) develop criteria for optimal selection and training of patients most likely to benefit from this technology, 2) design multimodal gait intention detection systems that engage and empower the user, 3) develop real-time monitoring and diagnostic capabilities, and 4) adopt comprehensive metrics for assessing safety, benefits, and usability.

Entities:  

Mesh:

Year:  2016        PMID: 27064508     DOI: 10.1088/1741-2560/13/3/031001

Source DB:  PubMed          Journal:  J Neural Eng        ISSN: 1741-2552            Impact factor:   5.379


  25 in total

1.  Workshops of the Seventh International Brain-Computer Interface Meeting: Not Getting Lost in Translation.

Authors:  Jane E Huggins; Christoph Guger; Erik Aarnoutse; Brendan Allison; Charles W Anderson; Steven Bedrick; Walter Besio; Ricardo Chavarriaga; Jennifer L Collinger; An H Do; Christian Herff; Matthias Hohmann; Michelle Kinsella; Kyuhwa Lee; Fabien Lotte; Gernot Müller-Putz; Anton Nijholt; Elmar Pels; Betts Peters; Felix Putze; Rüdiger Rupp; Gerwin Schalk; Stephanie Scott; Michael Tangermann; Paul Tubig; Thorsten Zander
Journal:  Brain Comput Interfaces (Abingdon)       Date:  2019-12-10

2.  Quasi-Direct Drive Actuation for a Lightweight Hip Exoskeleton with High Backdrivability and High Bandwidth.

Authors:  Shuangyue Yu; Tzu-Hao Huang; Xiaolong Yang; Chunhai Jiao; Jianfu Yang; Yue Chen; Jingang Yi; Hao Su
Journal:  IEEE ASME Trans Mechatron       Date:  2020-05-18       Impact factor: 5.303

Review 3.  Robotic Rehabilitation and Spinal Cord Injury: a Narrative Review.

Authors:  Marwa Mekki; Andrew D Delgado; Adam Fry; David Putrino; Vincent Huang
Journal:  Neurotherapeutics       Date:  2018-07       Impact factor: 7.620

4.  Decoding of Ankle Flexion and Extension from Cortical Current Sources Estimated from Non-invasive Brain Activity Recording Methods.

Authors:  Alejandra Mejia Tobar; Rikiya Hyoudou; Kahori Kita; Tatsuhiro Nakamura; Hiroyuki Kambara; Yousuke Ogata; Takashi Hanakawa; Yasuharu Koike; Natsue Yoshimura
Journal:  Front Neurosci       Date:  2018-01-08       Impact factor: 4.677

5.  Estimation of Neuromuscular Primitives from EEG Slow Cortical Potentials in Incomplete Spinal Cord Injury Individuals for a New Class of Brain-Machine Interfaces.

Authors:  Andrés Úbeda; José M Azorín; Dario Farina; Massimo Sartori
Journal:  Front Comput Neurosci       Date:  2018-01-25       Impact factor: 2.380

Review 6.  Robotic assisted gait as a tool for rehabilitation of individuals with spinal cord injury: a systematic review.

Authors:  Ledycnarf J Holanda; Patrícia M M Silva; Thiago C Amorim; Matheus O Lacerda; Camila R Simão; Edgard Morya
Journal:  J Neuroeng Rehabil       Date:  2017-12-04       Impact factor: 4.262

Review 7.  Risk management and regulations for lower limb medical exoskeletons: a review.

Authors:  Yongtian He; David Eguren; Trieu Phat Luu; Jose L Contreras-Vidal
Journal:  Med Devices (Auckl)       Date:  2017-05-09

8.  Locomotor training using an overground robotic exoskeleton in long-term manual wheelchair users with a chronic spinal cord injury living in the community: Lessons learned from a feasibility study in terms of recruitment, attendance, learnability, performance and safety.

Authors:  Dany H Gagnon; Manuel J Escalona; Martin Vermette; Lívia P Carvalho; Antony D Karelis; Cyril Duclos; Mylène Aubertin-Leheudre
Journal:  J Neuroeng Rehabil       Date:  2018-03-01       Impact factor: 4.262

9.  Technological Approaches for Neurorehabilitation: From Robotic Devices to Brain Stimulation and Beyond.

Authors:  Marianna Semprini; Matteo Laffranchi; Vittorio Sanguineti; Laura Avanzino; Roberto De Icco; Lorenzo De Michieli; Michela Chiappalone
Journal:  Front Neurol       Date:  2018-04-09       Impact factor: 4.003

10.  Evaluation of safety and performance of the self balancing walking system Atalante in patients with complete motor spinal cord injury.

Authors:  Jacques Kerdraon; Jean Gabriel Previnaire; Maegan Tucker; Pauline Coignard; Willy Allegre; Emmanuel Knappen; Aaron Ames
Journal:  Spinal Cord Ser Cases       Date:  2021-08-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.