Fabrication of a radiopaque fit-testing material to evaluate the three-dimensional accuracy of dental prostheses.

Yuzo Oka1, Jun-Ichi Sasaki2, Kazumichi Wakabayashi1, Yoshiro Nakano1, Shin-Ya Okamura1, Takashi Nakamura1, Satoshi Imazato3, Hirofumi Yatani1.   

Abstract

OBJECTIVES: The objective of this study was to fabricate a radiopaque prosthetic fit-testing material, and to develop methodology to evaluate the fitting accuracy of prostheses three-dimensionally (3D) using a combination of the silicone replica technique and micro-computed tomography (μCT).
METHODS: Eight types of prototype specimens of fit-testing materials were prepared by adding contrast agents (zirconia, alumina, and barium-glass) to a commercially available fit-testing material. These specimens were evaluated on their mechanical properties, X-ray absorption coefficients, reproducibility of cement space, and suitability for 3D analysis by μCT. Then, silicone replicas made from prototype specimens were assessed for accurate 3D morphology. Subsequently, color-mapping analyses of the silicone replicas were performed according to replica thickness, and the results were compared with stereomicroscopic images.
RESULTS: The mechanical properties, X-ray absorption coefficients, and reproducibility of the cement space demonstrated that prototypes containing 20wt% zirconia (Zr-20) or barium glass (diameter 2μm; Ba2-20) were useful as fit-testing materials. However, the morphology of the Ba2-20 silicone replica was unable to be accurately described using μCT because of its low X-ray absorption threshold. Zr-20, however, could be clearly observed on μCT imaging. Furthermore, color-mapping analysis of the μCT images demonstrated that Zr-20 was the most suitable for 3D observation of prosthetic fit. SIGNIFICANCE: This method could allow any professional to evaluate the fit of any type of dental prosthesis, such as inlays, crowns, and fixed and removable dentures. This study demonstrated that the technique presented in the current study is able to accurately describe the abutment-crown prosthetic discrepancy based on silicone replicas.
Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  3D analysis; CAD/CAM; Internal fit; Micro-computed tomography; Replica technique; Zirconia

Mesh:

Substances:

Year:  2016        PMID: 27063458     DOI: 10.1016/j.dental.2016.03.011

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  2 in total

1.  Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations.

Authors:  Mahya Hasanzade; Soudabeh Koulivand; Naeime Moslemian; Marzieh Alikhasi
Journal:  J Adv Prosthodont       Date:  2020-06-18       Impact factor: 1.904

2.  Three-dimensional misfit between Ti-Base abutments and implants evaluated by replica technique.

Authors:  Karina Bergamo Cardoso; Edmara Tatiely Pedroso Bergamo; Vitor De Moraes Cruz; Ilana Santos Ramalho; Lucas Fracassi De Oliveira Lino; Estevam Augusto Bonfante
Journal:  J Appl Oral Sci       Date:  2020-11-30       Impact factor: 2.698

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.