Literature DB >> 27058387

Performance of Three Single Instrument Systems in the Preparation of Long Oval Canals.

Beatriz Serrato Coelho1, Rodrigo Otavio Jatahy Ferreira do Amaral1, Denise Piotto Leonardi1, Bruno Marques-da-Silva1, Yara Teresinha Corrêa Silva-Sousa1, Fredson Marcio Acris de Carvalho1, Flares Baratto-Filho1.   

Abstract

This study aimed to evaluate the performance of the Wave One, Easy ProDesign Logic and One Shape systems in the preparation of long oval root canals. Forty-two mandibular incisors were randomized into three groups: Group I, Wave One Primary (WO) (#25.08); Group II, Easy ProDesign Logic (EPL) (#25.06) and Group III, One Shape (OS) (#25.06). Micro-computed tomography scans were obtained pre- and post-preparation of the samples. Instrument fractures or loss of working length did not occur in any of the groups. There was a statistically significant difference in total root canal volume between the WO and EPL (p<0.05) and OS systems (p<0.05) The mean percentages of instrumented canal area in the middle thirds were 76.9% in the WO, 62.3% in the EPL and 71.8% in the OS (p>0.05). The OS system had the strongest correlation between volume increase and instrumented area (R=0.63). The WO, EPL and OS systems presented mean preparation times of 2.13 min, 0.54 min, and 2.21 min (p<0.05), respectively. All three systems enabled the safe preparation of long oval root canals. The WO system most effectively increased root canal volume, but it did not affect the instrumented areas. The OS system had the strongest correlation between volume increase and instrumented area, while the EPL system was the fastest.

Entities:  

Mesh:

Year:  2016        PMID: 27058387     DOI: 10.1590/0103-6440201302449

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  4 in total

1.  Shaping ability of rotary or reciprocating systems for oval root canal preparation: a micro-computed tomography study.

Authors:  Camila Galletti Espir; Camila Almeida Nascimento-Mendes; Juliane Maria Guerreiro-Tanomaru; Bruno Cavalini Cavenago; Marco Antonio Hungaro Duarte; Mário Tanomaru-Filho
Journal:  Clin Oral Investig       Date:  2018-03-10       Impact factor: 3.573

2.  Cyclic Fatigue Resistance of WaveOne Gold, ProDesign R and ProDesign Logic Files in Curved Canals In Vitro.

Authors:  Sílvio Emanuel Acioly Conrado de Menezes; Shirley Machado Batista; Juliana Ouro Preto Lira; Gabriela Queiroz de Melo Monteiro
Journal:  Iran Endod J       Date:  2017

3.  Combination of a new ultrasonic tip with rotary systems for the preparation of flattened root canals.

Authors:  Karina Ines Medina Carita Tavares; Jáder Camilo Pinto; Airton Oliveira Santos-Junior; Fernanda Ferrari Esteves Torres; Juliane Maria Guerreiro-Tanomaru; Mario Tanomaru-Filho
Journal:  Restor Dent Endod       Date:  2021-10-27

4.  Incidence of fracture of ProDesign Logic system instruments: A cross-sectional retrospective study.

Authors:  Ricardo Machado; Claudemir de Souza Júnior; Bruna Larissa Mendes; Viviane Vieira; Stella Maria Glaci Reinke; Ana Cristina Gonçalves Kovalik; Eduardo Donato Eing Elgelke Back; Daniel Comparin
Journal:  Sci Rep       Date:  2022-05-12       Impact factor: 4.996

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.