Literature DB >> 27053432

Diagnostic Performance of a Cadmium-Zinc-Telluride Single-Photon Emission Computed Tomography System With Low-Dose Technetium-99m as Assessed by Fractional Flow Reserve.

Taishiro Chikamori1, Satoshi Hida, Nobuhiro Tanaka, Yuko Igarashi, Jun Yamashita, Chie Shiba, Naotaka Murata, Kou Hoshino, Yohei Hokama, Akira Yamashina.   

Abstract

BACKGROUND: Although stress single-photon emission computed tomography (SPECT) using a cadmium-zinc-telluride (CZT) camera facilitates radiation dose reduction, only a few studies have evaluated its diagnostic accuracy in Japanese patients by applying fractional flow reserve (FFR) measurements. METHODS AND 
RESULTS: We prospectively evaluated 102 consecutive patients with suspected or known coronary artery disease with a low-dose stress/rest protocol ((99m)Tc radiotracer 185/370 MBq) using CZT SPECT. Within 3 months, coronary angiography was performed and a significant stenosis was defined as ≥90% diameter narrowing on visual estimation, or as a lesion of <90% and ≥ 50% stenosis with FFR ≤0.80. To detect individual coronary stenosis, the respective sensitivity, specificity, and accuracy were 86%, 75%, and 82% for left anterior descending artery stenosis, 76%, 81%, and 79% for left circumflex artery stenosis, and 87%, 92%, and 90% for right coronary artery stenosis. When limited to 92 intermediate stenotic lesions in which FFR was measured, stress SPECT showed 77% sensitivity, 91% specificity, and 84% accuracy, whereas the diagnostic value decreased to 52% sensitivity, 68% specificity, and 58% accuracy based only on visual estimation of ≥75% diameter narrowing.
CONCLUSIONS: CZT SPECT demonstrated a good diagnostic yield in detecting hemodynamically significant coronary stenoses as assessed by FFR, even when using a low-dose (99m)Tc protocol with an effective dose ≤5 mSv. (Circ J 2016; 80: 1217-1224).

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27053432     DOI: 10.1253/circj.CJ-16-0087

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  3 in total

Review 1.  Emerging Tracers for Nuclear Cardiac PET Imaging.

Authors:  Dong-Yeon Kim; Sang-Geon Cho; Hee-Seung Bom
Journal:  Nucl Med Mol Imaging       Date:  2018-05-08

2.  Comparisons and contrasts in the practice of nuclear cardiology in the United States and Japan.

Authors:  E Gordon DePuey
Journal:  J Nucl Cardiol       Date:  2016-12       Impact factor: 5.952

3.  Diagnostic value of thallium-201 myocardial perfusion IQ-SPECT without and with computed tomography-based attenuation correction to predict clinically significant and insignificant fractional flow reserve: A single-center prospective study.

Authors:  Haruki Tanaka; Teruyuki Takahashi; Norihiko Ohashi; Koichi Tanaka; Takenori Okada; Yasuki Kihara
Journal:  Medicine (Baltimore)       Date:  2017-12       Impact factor: 1.817

  3 in total