Literature DB >> 27046884

Sparse Support Vector Machine for Intrapartum Fetal Heart Rate Classification.

Jiri Spilka1, Jordan Frecon1, Roberto Leonarduzzi1, Nelly Pustelnik1, Patrice Abry1, Muriel Doret2.   

Abstract

Fetal heart rate (FHR) monitoring is routinely used in clinical practice to help obstetricians assess fetal health status during delivery. However, early detection of fetal acidosis that allows relevant decisions for operative delivery remains a challenging task, receiving considerable attention. This contribution promotes sparse support vector machine classification that permits to select a small number of relevant features and to achieve efficient fetal acidosis detection. A comprehensive set of features is used for FHR description, including enhanced and computerized clinical features, frequency domain, and scaling and multifractal features, all computed on a large (1288 subjects) and well-documented database. The individual performance obtained for each feature independently is discussed first. Then, it is shown that the automatic selection of a sparse subset of features achieves satisfactory classification performance (sensitivity 0.73 and specificity 0.75, outperforming clinical practice). The subset of selected features (average depth of decelerations MADdtrd, baseline level β0 , and variability H) receives simple interpretation in clinical practice. Intrapartum fetal acidosis detection is improved in several respects: A comprehensive set of features combining clinical, spectral, and scale-free dynamics is used; an original multivariate classification targeting both sparse feature selection and high performance is devised; state-of-the-art performance is obtained on a much larger database than that generally studied with description of common pitfalls in supervised classification performance assessments.

Entities:  

Mesh:

Year:  2016        PMID: 27046884     DOI: 10.1109/JBHI.2016.2546312

Source DB:  PubMed          Journal:  IEEE J Biomed Health Inform        ISSN: 2168-2194            Impact factor:   5.772


  3 in total

1.  Computer-based intrapartum fetal monitoring and beyond: A review of the 2nd Workshop on Signal Processing and Monitoring in Labor (October 2017, Oxford, UK).

Authors:  Antoniya Georgieva; Patrice Abry; Václav Chudáček; Petar M Djurić; Martin G Frasch; René Kok; Christopher A Lear; Sebastiaan N Lemmens; Inês Nunes; Aris T Papageorghiou; Gerald J Quirk; Christopher W G Redman; Barry Schifrin; Jiri Spilka; Austin Ugwumadu; Rik Vullings
Journal:  Acta Obstet Gynecol Scand       Date:  2019-06-18       Impact factor: 3.636

2.  Prediction of intrapartum fetal hypoxia considering feature selection algorithms and machine learning models.

Authors:  Zafer Cömert; Abdulkadir Şengür; Ümit Budak; Adnan Fatih Kocamaz
Journal:  Health Inf Sci Syst       Date:  2019-08-20

3.  A systematic review of automated pre-processing, feature extraction and classification of cardiotocography.

Authors:  Shahad Al-Yousif; Ariep Jaenul; Wisam Al-Dayyeni; Ah Alamoodi; Ihab Jabori; Nooritawati Md Tahir; Ali Amer Ahmed Alrawi; Zafer Cömert; Nael A Al-Shareefi; Abbadullah H Saleh
Journal:  PeerJ Comput Sci       Date:  2021-04-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.