Literature DB >> 27045969

Single-Site Low-Flow Veno-Venous Extracorporeal Lung Support Does Not Influence Hemodynamic Monitoring by Transpulmonary Thermodilution.

Bassam Redwan1, Stephan Ziegeler, Stefan Freermann, Thomas Meemann, Michael Semik, Nicolas Dickgerber, Stefan Fischer.   

Abstract

The application of extracorporeal lung support (ECLS) in patients with acute respiratory distress syndrome is a well-established concept. In patients receiving ECLS therapy, hemodynamic monitoring is often required. However, less is known about the effect of ECLS on hemodynamic measurements. In the present work, the influence of single-site low-flow veno-venous ECLS (LFVV-ECLS) on hemodynamic monitoring by transpulmonary thermodilution (TPTD) was prospectively investigated. Five consecutive patients undergoing single-site LFVV-ECLS for severe hypercapnic respiratory failure were included in this study. For single-site LFVV-ECLS, a 22 Fr twin-port double-lumen cannula was inserted percutaneously into the right jugular vein. Hemodynamic monitoring was performed using the Pulse index Continuous Cardiac Output system. Before ECLS initiation, baseline measurements of cardiac index, systemic vascular resistance, mean arterial pressure, and extravascular lung water (EVLW) were performed. During the first 3 days of ECLS therapy, repeated hemodynamic measurements at different ECLS flow rates were performed. No significant differences were seen in hemodynamic measurements. With respect to EVLW, a significant decrease over the duration of ECLS therapy was observed. This study demonstrates that LFVV-ECLS does not interfere with TPTD. It needs to be further studied if these findings also apply to other ECLS modes.

Entities:  

Mesh:

Year:  2016        PMID: 27045969     DOI: 10.1097/MAT.0000000000000379

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

1.  Transpulmonary thermodilution before and during veno-venous extra-corporeal membrane oxygenation ECMO: an observational study on a potential loss of indicator into the extra-corporeal circuit.

Authors:  Alexander Herner; Tobias Lahmer; Ulrich Mayr; Sebastian Rasch; Jochen Schneider; Roland M Schmid; Wolfgang Huber
Journal:  J Clin Monit Comput       Date:  2019-11-05       Impact factor: 2.502

Review 2.  Hemodynamic monitoring in patients with venoarterial extracorporeal membrane oxygenation.

Authors:  Ying Su; Kai Liu; Ji-Li Zheng; Xin Li; Du-Ming Zhu; Ying Zhang; Yi-Jie Zhang; Chun-Sheng Wang; Tian-Tian Shi; Zhe Luo; Guo-Wei Tu
Journal:  Ann Transl Med       Date:  2020-06

Review 3.  Extravascular lung water measurements in acute respiratory distress syndrome: why, how, and when?

Authors:  Takashi Tagami; Marcus Eng Hock Ong
Journal:  Curr Opin Crit Care       Date:  2018-06       Impact factor: 3.687