Literature DB >> 27044847

On-Chip Micro-Electro-Mechanical System Fourier Transform Infrared (MEMS FT-IR) Spectrometer-Based Gas Sensing.

Mazen Erfan1, Yasser M Sabry2, Mohammad Sakr3, Bassem Mortada4, Mostafa Medhat4, Diaa Khalil2.   

Abstract

In this work, we study the detection of acetylene (C2H2), carbon dioxide (CO2) and water vapor (H2O) gases in the near-infrared (NIR) range using an on-chip silicon micro-electro-mechanical system (MEMS) Fourier transform infrared (FT-IR) spectrometer in the wavelength range 1300-2500 nm (4000-7692 cm(-1)). The spectrometer core engine is a scanning Michelson interferometer micro-fabricated using a deep-etching technology producing self-aligned components. The light is free-space propagating in-plane with respect to the silicon chip substrate. The moving mirror of the interferometer is driven by a relatively large stroke electrostatic comb-drive actuator corresponding to about 30 cm(-1) resolution. Multi-mode optical fibers are used to connect light between the wideband light source, the interferometer, the 10 cm gas cell, and the optical detector. A wide dynamic range of gas concentration down to 2000 parts per million (ppm) in only 10 cm length gas cell is demonstrated. Extending the wavelength range to the mid-infrared (MIR) range up to 4200 nm (2380 cm(-1)) is also experimentally demonstrated, for the first time, using a bulk micro-machined on-chip MEMS FT-IR spectrometer. The obtained results open the door for an on-chip optical gas sensor for many applications including environmental sensing and industrial process control in the NIR/MIR spectral ranges.
© The Author(s) 2016.

Entities:  

Keywords:  Gas detection; MEMS technology; MIR spectrometer; NIR spectroscopy; micro-electro-mechanical systems; micro-optical bench technology; mid-infrared spectrometer; near-infrared; portable spectrometer; spectral-based sensor

Year:  2016        PMID: 27044847     DOI: 10.1177/0003702816638295

Source DB:  PubMed          Journal:  Appl Spectrosc        ISSN: 0003-7028            Impact factor:   2.388


  7 in total

1.  Fourier transform spectrometer on silicon with thermo-optic non-linearity and dispersion correction.

Authors:  Mario C M M Souza; Andrew Grieco; Newton C Frateschi; Yeshaiahu Fainman
Journal:  Nat Commun       Date:  2018-02-14       Impact factor: 14.919

2.  Functionalizing a Tapered Microcavity as a Gas Cell for On-Chip Mid-Infrared Absorption Spectroscopy.

Authors:  N Pelin Ayerden; Julien Mandon; Frans J M Harren; Reinoud F Wolffenbuttel
Journal:  Sensors (Basel)       Date:  2017-09-06       Impact factor: 3.576

Review 3.  Towards Integrated Mid-Infrared Gas Sensors.

Authors:  Daniel Popa; Florin Udrea
Journal:  Sensors (Basel)       Date:  2019-05-04       Impact factor: 3.576

4.  Probeless non-invasive near-infrared spectroscopic bioprocess monitoring using microspectrometer technology.

Authors:  Robert Zimmerleiter; Julian Kager; Ramin Nikzad-Langerodi; Vladimir Berezhinskiy; Frank Westad; Christoph Herwig; Markus Brandstetter
Journal:  Anal Bioanal Chem       Date:  2019-12-04       Impact factor: 4.142

5.  Mixed-gas CH4/CO2/CO detection based on linear variable optical filter and thermopile detector array.

Authors:  Shaoda Zhang; Wu Bin; Binbin Xu; Xingyu Zheng; Binbin Chen; Xueqin Lv; Haisheng San; Werner Hofmann
Journal:  Nanoscale Res Lett       Date:  2019-11-25       Impact factor: 4.703

6.  Dual Tunable MZIs Stationary-Wave Integrated Fourier Transform Spectrum Detection.

Authors:  Xinyang Chen; Peijian Huang; Ning Wang; Yong Zhu; Jie Zhang
Journal:  Sensors (Basel)       Date:  2021-03-28       Impact factor: 3.576

7.  A Laser-Based Multipass Absorption Sensor for Sub-ppm Detection of Methane, Acetylene and Ammonia.

Authors:  Wei Duan; Fuwu Yan; Yu Wang; Hui Zhang; Liuhao Ma; Daxin Wen; Wei Wang; Gang Sheng; Qiang Wang
Journal:  Sensors (Basel)       Date:  2022-01-12       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.