Clinical trial design and rationale of the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) investigational device exemption clinical study protocol.

Gerald Heatley1, Poornima Sood2, Daniel Goldstein3, Nir Uriel4, Joseph Cleveland5, Don Middlebrook2, Mandeep R Mehra6.   

Abstract

The HeartMate 3 left ventricular assist system (LVAS; St. Jude Medical, Inc., formerly Thoratec Corporation, Pleasanton, CA) was recently introduced into clinical trials for durable circulatory support in patients with medically refractory advanced-stage heart failure. This centrifugal, fully magnetically levitated, continuous-flow pump is engineered with the intent to enhance hemocompatibility and reduce shear stress on blood elements, while also possessing intrinsic pulsatility. Although bridge-to-transplant (BTT) and destination therapy (DT) are established dichotomous indications for durable left ventricular assist device (LVAD) support, clinical practice has challenged the appropriateness of these designations. The introduction of novel LVAD technology allows for the development of clinical trial designs to keep pace with current practices. The prospective, randomized Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) clinical trial aims to evaluate the safety and effectiveness of the HeartMate 3 LVAS by demonstrating non-inferiority to the HeartMate II LVAS (also St. Jude Medical, Inc.). The innovative trial design includes patients enrolled under a single inclusion and exclusion criteria , regardless of the intended use of the device, with outcomes ascertained in the short term (ST, at 6 months) and long term (LT, at 2 years). This adaptive trial design includes a pre-specified safety phase (n = 30) analysis. The ST cohort includes the first 294 patients and the LT cohort includes the first 366 patients for evaluation of the composite primary end-point of survival to transplant, recovery or LVAD support free of debilitating stroke (modified Rankin score >3), or re-operation to replace the pump. As part of the adaptive design, an analysis by an independent statistician will determine whether sample size adjustment is required at pre-specified times during the study. A further 662 patients will be enrolled to reach a total of 1,028 patients for evaluation of the secondary end-point of pump replacement at 2 years.
Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  HeartMate 3; LVAD; MOMENTUM 3; MagLev; advanced heart failure

Mesh:

Year:  2016        PMID: 27044532     DOI: 10.1016/j.healun.2016.01.021

Source DB:  PubMed          Journal:  J Heart Lung Transplant        ISSN: 1053-2498            Impact factor:   10.247


  24 in total

1.  The Adaptive designs CONSORT Extension (ACE) statement: a checklist with explanation and elaboration guideline for reporting randomised trials that use an adaptive design.

Authors:  Munyaradzi Dimairo; Philip Pallmann; James Wason; Susan Todd; Thomas Jaki; Steven A Julious; Adrian P Mander; Christopher J Weir; Franz Koenig; Marc K Walton; Jon P Nicholl; Elizabeth Coates; Katie Biggs; Toshimitsu Hamasaki; Michael A Proschan; John A Scott; Yuki Ando; Daniel Hind; Douglas G Altman
Journal:  BMJ       Date:  2020-06-17

2.  A roadmap for evaluating the use and value of durable ventricular assist device therapy.

Authors:  Sarah T Ward; Qixing Liang; Francis D Pagani; Min Zhang; Robert L Kormos; Keith D Aaronson; Andrew D Althouse; Brahmajee K Nallamothu; Donald S Likosky
Journal:  J Heart Lung Transplant       Date:  2017-06-23       Impact factor: 10.247

3.  Novel centrifugal pump for heart failure patients: initial success and future challenges.

Authors:  Christina Feldmann; Anamika Chatterjee; Jasmin S Hanke; Guenes Dogan; Axel Haverich; Jan D Schmitto
Journal:  J Thorac Dis       Date:  2017-06       Impact factor: 2.895

4.  HeartMate 3-a "Step" in the right direction.

Authors:  Juglans Alvarez; Vivek Rao
Journal:  J Thorac Dis       Date:  2017-05       Impact factor: 2.895

Review 5.  Recommendations on the use of innovative medical technologies in cardiology and cardiac surgery and solutions leading to increased availability for Polish patients.

Authors:  Dariusz Dudek; Waldemar Banasiak; Wojciech Braksator; Jacek Dubiel; Tomasz Grodzicki; Piotr Hoffman; Mariusz Kuśmierczyk; Grzegorz Opolski; Piotr Ponikowski; Jacek Różański; Jerzy Sadowski; Wojciech Wojakowski; Marcin Grabowski; Katarzyna Bondaryk; Jacek Walczak; Izabela Pieniążek; Maciej Grys; Anna Lesiak-Bednarek; Piotr Przygodzki
Journal:  Cardiol J       Date:  2019-02-14       Impact factor: 2.737

6.  Effect of aspirin dose on hemocompatibility-related outcomes with a magnetically levitated left ventricular assist device: An analysis from the MOMENTUM 3 study.

Authors:  Omar Saeed; Paolo C Colombo; Mandeep R Mehra; Nir Uriel; Daniel J Goldstein; Joseph Cleveland; Jean M Connors; Samer S Najjar; Nahush A Mokadam; Aditya Bansal; Daniel L Crandall; Poornima Sood; Ulrich P Jorde
Journal:  J Heart Lung Transplant       Date:  2020-03-20       Impact factor: 10.247

Review 7.  Left Ventricular Assist Device as Destination Therapy: a State of the Science and Art of Long-Term Mechanical Circulatory Support.

Authors:  Thomas C Hanff; Edo Y Birati
Journal:  Curr Heart Fail Rep       Date:  2019-10

Review 8.  How New Support Devices Change Critical Care Delivery.

Authors:  Asma Zainab; Divina Tuazon; Faisal Uddin; Iqbal Ratnani
Journal:  Methodist Debakey Cardiovasc J       Date:  2018 Apr-Jun

9.  Surgical Management of Heart Failure.

Authors:  Stephanie L Wayne; Adam D Zimmet
Journal:  Curr Cardiol Rev       Date:  2021

10.  The adaptive designs CONSORT extension (ACE) statement: a checklist with explanation and elaboration guideline for reporting randomised trials that use an adaptive design.

Authors:  Munyaradzi Dimairo; Philip Pallmann; James Wason; Susan Todd; Thomas Jaki; Steven A Julious; Adrian P Mander; Christopher J Weir; Franz Koenig; Marc K Walton; Jon P Nicholl; Elizabeth Coates; Katie Biggs; Toshimitsu Hamasaki; Michael A Proschan; John A Scott; Yuki Ando; Daniel Hind; Douglas G Altman
Journal:  Trials       Date:  2020-06-17       Impact factor: 2.279

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.