Rapid electrical immunoassay of the cardiac biomarker troponin I through dielectrophoretic concentration using imbedded electrodes.

Abhinav Sharma1, Chang-Ho Han1, Jaesung Jang2.   

Abstract

Rapidity and high sensitivity are critical factors for the diagnoses of heart attacks, and cardiac troponin I (cTnI) is at present a clinical standard for its diagnosis. Here we report a rapid, label-free, and highly sensitive single-walled carbon nanotube (SWCNT) electrical immunosensor, featuring two pairs of electrodes. Two concentration electrodes (gaps: 25 and 80µm) and two detection electrodes (source and drain; gap: 20µm; width: 50µm) were used for dielectrophoretic concentration of cTnI on the SWCNT channels and resistance measurements of the dielectrophoresis (DEP)-concentrated cTnI, respectively. The two concentration electrodes were imbedded between upper and lower dielectric layers, facing each other, underneath the -COOH-functionalized SWCNT channels deposited between the detection electrodes. Therefore, the gap between these imbedded concentration electrodes can be reduced to maximize the electric field intensity for DEP-mediated concentration of cTnI, thereby greatly reducing the detection time (1min) and enhancing the limit of detection (0.7-0.8pgmL(-)(1)). Relative resistance changes of the SWCNTs were measured as cTnI concentration in Tris-Borate-EDTA (TBE; 0.0025×) and human serum diluted 500-fold with 0.0025× TBE decreased from 100ngmL(-)(1) to 1pgmL(-1), and they were shown to be linear with the logarithm of cTnI concentration (R(2)=0.99 and 0.97, respectively). These immunosensors also showed high specificity over another cardiac biomarker, myoglobin, TBE medium (0.0025×), and 500-fold diluted human serum. The DEP-capture of cTnI depended on the frequency of the applied electric field, demonstrating the qualitative nature of the real part of the Clausius-Mossotti factor for cTnI.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Carbon nanotubes; Cardiac troponin I; Cardiovascular disease; Dielectrophoresis; Immunoassay

Mesh:

Substances:

Year:  2016        PMID: 27043478     DOI: 10.1016/j.bios.2016.03.056

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  8 in total

1.  Dielectrophoresis of proteins: experimental data and evolving theory.

Authors:  Mark A Hayes
Journal:  Anal Bioanal Chem       Date:  2020-04-21       Impact factor: 4.142

2.  Flexible electrical aptasensor using dielectrophoretic assembly of graphene oxide and its subsequent reduction for cardiac biomarker detection.

Authors:  Abhinav Sharma; Jaesung Jang
Journal:  Sci Rep       Date:  2019-04-12       Impact factor: 4.379

Review 3.  Evaluation of Molecularly Imprinted Polymers for Point-of-Care Testing for Cardiovascular Disease.

Authors:  Brian Regan; Fiona Boyle; Richard O'Kennedy; David Collins
Journal:  Sensors (Basel)       Date:  2019-08-09       Impact factor: 3.576

4.  Protein Dielectrophoresis: I. Status of Experiments and an Empirical Theory.

Authors:  Ralph Hölzel; Ronald Pethig
Journal:  Micromachines (Basel)       Date:  2020-05-22       Impact factor: 2.891

5.  Paper-based electrochemical immunosensor for label-free detection of multiple avian influenza virus antigens using flexible screen-printed carbon nanotube-polydimethylsiloxane electrodes.

Authors:  Daesoon Lee; Jyoti Bhardwaj; Jaesung Jang
Journal:  Sci Rep       Date:  2022-02-10       Impact factor: 4.379

6.  Rapid and selective concentration of bacteria, viruses, and proteins using alternating current signal superimposition on two coplanar electrodes.

Authors:  Chang-Ho Han; Seong Yong Woo; Jyoti Bhardwaj; Abhinav Sharma; Jaesung Jang
Journal:  Sci Rep       Date:  2018-10-08       Impact factor: 4.379

7.  Label-Free, Highly Sensitive Electrochemical Aptasensors Using Polymer-Modified Reduced Graphene Oxide for Cardiac Biomarker Detection.

Authors:  Abhinav Sharma; Jyoti Bhardwaj; Jaesung Jang
Journal:  ACS Omega       Date:  2020-02-18

Review 8.  Biosensors Based on Mechanical and Electrical Detection Techniques.

Authors:  Thomas Chalklen; Qingshen Jing; Sohini Kar-Narayan
Journal:  Sensors (Basel)       Date:  2020-09-30       Impact factor: 3.576

  8 in total