Mukesh Nasa1, Zubin Dev Sharma2, Narendra S Choudhary2, Rajesh Puri2, Randhir Sud2. 1. Department of Gastroenterology, Institute of Digestive and Hepatobiliary Sciences, Medanta-The Medicity, Sector 38, Gurgaon, Delhi NCR, 122 001, India. mukeshnasa78@gmail.com. 2. Department of Gastroenterology, Institute of Digestive and Hepatobiliary Sciences, Medanta-The Medicity, Sector 38, Gurgaon, Delhi NCR, 122 001, India.
Abstract
BACKGROUND: Esophageal rupture, spontaneous or iatrogenic, is associated with significant morbidity and mortality. The current study aims at highlighting the various clinical scenarios, where esophageal fully covered self-expanding removable metal stents (FCSEMS) can be used in esophageal rupture. METHODS: In patients who underwent insertion of FCSEMS between January 2013 and June 2014, all data regarding demographics, indications, insertion, removal, and outcomes were studied retrospectively. RESULTS: Seven patients underwent the placement of esophageal covered SEMS. Two patients had Boerhaave syndrome, two had leak following the repair of aortic aneurysm, one had extensive esophageal injury following transesophageal echocardiography, one had carcinoma esophagus with tracheaesophageal fistula, and one had dehiscence of esophagogastric anastomosis. Stent insertion was successful in all the patients; one had stent migration which was managed endoscopically. Two patients died due to underlying illness; the rest had successful removal of stents after 8-10 weeks and good outcomes. CONCLUSION: Esophageal FCSEMS placement is safe and effective modality in management of patients with esophageal rupture.
BACKGROUND:Esophageal rupture, spontaneous or iatrogenic, is associated with significant morbidity and mortality. The current study aims at highlighting the various clinical scenarios, where esophageal fully covered self-expanding removable metal stents (FCSEMS) can be used in esophageal rupture. METHODS: In patients who underwent insertion of FCSEMS between January 2013 and June 2014, all data regarding demographics, indications, insertion, removal, and outcomes were studied retrospectively. RESULTS: Seven patients underwent the placement of esophageal covered SEMS. Two patients had Boerhaave syndrome, two had leak following the repair of aortic aneurysm, one had extensive esophageal injury following transesophageal echocardiography, one had carcinoma esophagus with tracheaesophageal fistula, and one had dehiscence of esophagogastric anastomosis. Stent insertion was successful in all the patients; one had stent migration which was managed endoscopically. Two patients died due to underlying illness; the rest had successful removal of stents after 8-10 weeks and good outcomes. CONCLUSION: Esophageal FCSEMS placement is safe and effective modality in management of patients with esophageal rupture.
Authors: Herbert De Praetere; Philip Lerut; Mertens Johan; Kim Daenens; Sabrina Houthoofd; Inge Fourneau; Geert Maleux; Toni Lerut; Andre Nevelsteen Journal: Ann Vasc Surg Date: 2010-11 Impact factor: 1.466
Authors: James K Min; Kirk T Spencer; Kathy T Furlong; Jeanne M DeCara; Lissa Sugeng; R Parker Ward; Roberto M Lang Journal: J Am Soc Echocardiogr Date: 2005-09 Impact factor: 5.251
Authors: R Chiesa; G Melissano; E M Marone; M M Marrocco-Trischitta; A Kahlberg Journal: Eur J Vasc Endovasc Surg Date: 2010-01-21 Impact factor: 7.069
Authors: S H Roy-Choudhury; A A Nicholson; K R Wedgwood; R A Mannion; P C Sedman; C M Royston; D J Breen Journal: AJR Am J Roentgenol Date: 2001-01 Impact factor: 3.959