Literature DB >> 27039202

Microscopic imaging and tuning of electrogenerated chemiluminescence with boron-doped diamond nanoelectrode arrays.

Milica Sentic1,2, Francesca Virgilio3,4, Alessandra Zanut3,4, Dragan Manojlovic2, Stéphane Arbault1, Massimo Tormen3, Neso Sojic1, Paolo Ugo5.   

Abstract

Nanoelectrode arrays (NEAs) are increasingly applied for a variety of electroanalytical applications; however, very few studies dealt with the use of NEAs as an electrochemical generator of electrogenerated chemiluminescence (ECL). In the present study, arrays of nanodisc and nanoband electrodes with different dimensions and inter-electrode distances were fabricated by e-beam lithography on a polycarbonate layer deposited on boron-doped diamond (BDD) substrates. In particular, NEAs with 16 different geometries were fabricated on the same BDD sample substrate obtaining a multiple nanoelectrode and ultramicroelectrode array platform (MNEAP). After electrochemical and morphological characterization, the MNEAP was used to capture simultaneously with a single image the characteristic behaviour of ECL emission from all the 16 arrays. Experiments were performed using Ru(bpy)3 (2+) as the ECL luminophore and tri-n-propylamine (TPrA) as the co-reactant. With a relatively limited number of experiments, such an imaging procedure allowed to study the role that geometrical and mechanistic parameters play on ECL generation at NEAs. In particular, at high concentrations of TPrA, well-separated individual ECL spots or bands revealed an ECL signal which forms a pattern matching the nanofabricated structure. The analysis of the imaging data indicated that the thickness of the ECL-emitting zone at each nanoelectrode scales inversely with the co-reactant concentration, while significantly stronger ECL signals were detected for NEAs operating under overlap conditions.

Entities:  

Keywords:  Array; Boron-doped diamond; Electrogenerated chemiluminescence; Imaging; Microscopy; Nanoelectrode

Year:  2016        PMID: 27039202     DOI: 10.1007/s00216-016-9504-1

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  3 in total

Review 1.  Nanobiosensing with Arrays and Ensembles of Nanoelectrodes.

Authors:  Najmeh Karimian; Ligia M Moretto; Paolo Ugo
Journal:  Sensors (Basel)       Date:  2016-12-30       Impact factor: 3.576

Review 2.  Micro/Nano Electrode Array Sensors: Advances in Fabrication and Emerging Applications in Bioanalysis.

Authors:  Yang Liu; Xiuting Li; Jie Chen; Chonglin Yuan
Journal:  Front Chem       Date:  2020-11-13       Impact factor: 5.221

3.  Nanoelectrode Arrays Fabricated by Thermal Nanoimprint Lithography for Biosensing Application.

Authors:  Alessandra Zanut; Alessandro Cian; Nicola Cefarin; Alessandro Pozzato; Massimo Tormen
Journal:  Biosensors (Basel)       Date:  2020-08-05
  3 in total