Literature DB >> 2703651

Portable tonometers: a clinical comparison of applanation and indentation devices.

G F Chiara1, L P Semes, J W Potter, G R Cutter, W R Tucker.   

Abstract

Optometric services to outpatient clinics, nursing homes and hospitals require portable equipment for ocular assessment. Of the various tonometric methods available, Goldmann applanation tonometry remains the standard. We present a clinical comparison of the hand-held version of Goldmann's instrument (Perkins tonometer) and the less expensive Schiotz tonometer. In a clinical comparison, we measured the intraocular pressure (IOP) of 51 inpatient and outpatient veterans (100 eyes) during routine examination. In each case the Perkins applanation tonometer was used first. This measurement was followed by IOP measurements using the Schiotz indentation tonometer with the 7.5 g and 5.5 g plunger loads. Plunger loads were alternated so that each was used, initially, 50% of the time. Good correlations, ranging from +.85 to +.68, were achieved between the applanation and indentation modes. Compact portability, lower cost and comparable reliability make the Schiotz tonometer a viable option for IOP screening.

Entities:  

Mesh:

Year:  1989        PMID: 2703651

Source DB:  PubMed          Journal:  J Am Optom Assoc        ISSN: 0003-0244


  4 in total

1.  Effect of the Honan intraocular pressure reducer on intraocular pressure increase following intravitreal injection using the tunneled scleral technique.

Authors:  Kyu-Seop Kim; Donghyun Jee
Journal:  Jpn J Ophthalmol       Date:  2011-09-23       Impact factor: 2.447

2.  Impact of injection techniques on intraocular pressure (IOP) increase after intravitreal ranibizumab application.

Authors:  Fabian Höhn; Alireza Mirshahi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-04-21       Impact factor: 3.117

Review 3.  Portable hardware & software technologies for addressing ophthalmic health disparities: A systematic review.

Authors:  Margarita Labkovich; Megan Paul; Eliott Kim; Randal A Serafini; Shreyas Lakhtakia; Aly A Valliani; Andrew J Warburton; Aashay Patel; Davis Zhou; Bonnie Sklar; James Chelnis; Ebrahim Elahi
Journal:  Digit Health       Date:  2022-05-06

4.  Comparative evaluation of applanation and indentation tonometers in a community ophthalmology setting in Southern India.

Authors:  Swathi Nagarajan; Veerabahu Velayutham; G Ezhumalai
Journal:  Saudi J Ophthalmol       Date:  2015-11-19
  4 in total