PURPOSE: We compared signal change on magnetic resonance imaging (MRI) with fat suppression and bone scan activity of lumbar facet joints to determine if these two imaging findings are correlated. METHODS: We retrospectively identified all patients who underwent imaging of the lumbar spine for pain evaluation using both technetium-99m methylene disphosphonate single-photon emission computed tomography/computed tomography (99mTc-MDP SPECT/CT) and MRI with at least one fat-suppressed T2- or T1-weighted sequence with gadolinium enhancement within a 180-day interval, at our institution between 1 January 2008 and 19 February 2013. Facet joint activity on 99mTc-MDP SPECT/CT and peri-facet signal change on MRI were rated as normal or increased. Agreement between the two examination types were determined with the κ and prevalence-adjusted bias-adjusted κ (PABAK) statistics. RESULTS: This study included 60 patients (28 male, 47%), with a mean age of 49±19.7 years (range, 12-93 years). The κ value indicated no agreement between 99mTc-MDP SPECT/CT and MRI (κ=-0.026; 95% confidence interval: -0.051, 0.000). The PABAK values were fair to high at each spinal level, which suggests that relatively low disease prevalence lowered the κ values. Together, the κ and PABAK values indicate that there is some degree of intermodality agreement, but that it is not consistent. CONCLUSION: Overall, facet joint signal change on fat-suppressed MRI did not always correlate with increased 99mTc-MDP SPECT/CT activity. MRI and 99mTc-MDP SPECT/CT for facet joint evaluation should not be considered interchangeable examinations in clinical practice or research.
PURPOSE: We compared signal change on magnetic resonance imaging (MRI) with fat suppression and bone scan activity of lumbar facet joints to determine if these two imaging findings are correlated. METHODS: We retrospectively identified all patients who underwent imaging of the lumbar spine for pain evaluation using both technetium-99m methylene disphosphonate single-photon emission computed tomography/computed tomography (99mTc-MDP SPECT/CT) and MRI with at least one fat-suppressed T2- or T1-weighted sequence with gadolinium enhancement within a 180-day interval, at our institution between 1 January 2008 and 19 February 2013. Facet joint activity on 99mTc-MDP SPECT/CT and peri-facet signal change on MRI were rated as normal or increased. Agreement between the two examination types were determined with the κ and prevalence-adjusted bias-adjusted κ (PABAK) statistics. RESULTS: This study included 60 patients (28 male, 47%), with a mean age of 49±19.7 years (range, 12-93 years). The κ value indicated no agreement between 99mTc-MDP SPECT/CT and MRI (κ=-0.026; 95% confidence interval: -0.051, 0.000). The PABAK values were fair to high at each spinal level, which suggests that relatively low disease prevalence lowered the κ values. Together, the κ and PABAK values indicate that there is some degree of intermodality agreement, but that it is not consistent. CONCLUSION: Overall, facet joint signal change on fat-suppressed MRI did not always correlate with increased 99mTc-MDP SPECT/CT activity. MRI and 99mTc-MDP SPECT/CT for facet joint evaluation should not be considered interchangeable examinations in clinical practice or research.
Authors: Spiros G Pneumaticos; Sofia N Chatziioannou; John A Hipp; Warren H Moore; Stephen I Esses Journal: Radiology Date: 2006-02 Impact factor: 11.105
Authors: V T Lehman; R C Murphy; T J Kaufmann; F E Diehn; N S Murthy; J T Wald; K R Thielen; K K Amrami; J M Morris; T P Maus Journal: AJNR Am J Neuroradiol Date: 2013-09-12 Impact factor: 3.825
Authors: David M Dansie; Patrick H Luetmer; John I Lane; Kent R Thielen; John T Wald; David F Kallmes Journal: AJNR Am J Neuroradiol Date: 2005 Jun-Jul Impact factor: 3.825