Literature DB >> 27034069

Effects of protein leakage on online monitoring of ultraviolet absorbance in spent dialysate.

Ken-Ichiro Yamamoto1, Shinya Hirakawa2, Jun Murakami2, Takashi Akiba3, Michio Mineshima2.   

Abstract

Recently, dialysis dose during hemodialysis treatment has been monitored by measuring the concentration of urea-like solutes such as uric acid in spent dialysate using near-ultraviolet (UV) light. The measured absorbance has been shown to have a good correlation with the time course of urea level even if the absorbance does not result from urea. However, the spent dialysate includes various solutes such as uric acid and albumin as well as unknown solutes that also absorb UV light. The effects of these solutes on monitored absorbance values are not clear. In this study, we evaluated the effect of protein leakage on data from the UV monitoring of spent dialysate. Albumin leakage in the earlier stage of the treatment may result in an increase in absorbance greater than the expected value. As a result, there is a possibility that the dialysis dose is overestimated. On the other hand, the quantity of albumin leakage could be estimated by a spent dialysate monitoring technique combined with a protein removal process.

Entities:  

Keywords:  Dialysis dose monitoring; Protein; Spectrophotometry; Spent dialysate; Ultraviolet absorbance

Mesh:

Substances:

Year:  2016        PMID: 27034069     DOI: 10.1007/s10047-016-0897-6

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  6 in total

1.  Automated monitoring of hemodialysis adequacy by dialysis machines: potential benefits to patients and cost savings.

Authors:  John T Daugirdas; James E Tattersall
Journal:  Kidney Int       Date:  2010-11       Impact factor: 10.612

2.  Dialysis dose (Kt/V) and clearance variation sensitivity using measurement of ultraviolet-absorbance (on-line), blood urea, dialysate urea and ionic dialysance.

Authors:  Fredrik Uhlin; Ivo Fridolin; Martin Magnusson; Lars-Göran Lindberg
Journal:  Nephrol Dial Transplant       Date:  2006-04-12       Impact factor: 5.992

3.  On-line monitoring of solutes in dialysate using absorption of ultraviolet radiation: technique description.

Authors:  I Fridolin; M Magnusson; L G Lindberg
Journal:  Int J Artif Organs       Date:  2002-08       Impact factor: 1.595

4.  Estimation of delivered dialysis dose by on-line monitoring of the ultraviolet absorbance in the spent dialysate.

Authors:  Fredrik Uhlin; Ivo Fridolin; Lars-Göran Lindberg; Martin Magnusson
Journal:  Am J Kidney Dis       Date:  2003-05       Impact factor: 8.860

5.  Urea monitoring during dialysis: the wave of the future. A tale of two cities.

Authors:  R M Lindsay; A P Heidenheim; E Spanner; J Baird; K Simpson; M E Allison
Journal:  ASAIO Trans       Date:  1991 Apr-Jun

6.  Uric acid is the major determinant of absorbance in spent dialysate allowing spectrophotometric evaluation of dialysis dose.

Authors:  Carlo Donadio; Dario Calia; Silvia Ghimenti; Massimo Onor; Elisa Colombini; Roger Fuoco; Fabio Di Francesco
Journal:  J Nephrol       Date:  2013-12-07       Impact factor: 3.902

  6 in total
  1 in total

Review 1.  Journal of Artificial Organs 2016: the year in review : Journal of Artificial Organs Editorial Committee.

Authors:  Y Sawa; G Matsumiya; K Matsuda; E Tatsumi; T Abe; K Fukunaga; S Ichiba; A Kishida; K Kokubo; T Masuzawa; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; T Tsukiya; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2017-02-14       Impact factor: 1.731

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.