In this contribution, we propose a label-free immunosensor, based on a novel type of electrolyte-gated field-effect transistor (EGOFET), for ultrasensitive detection of the C-reactive protein (CRP). The recognition layer of the biosensor is fabricated by physical adsorption of the anti-CRP monoclonal antibody onto a poly-3-hexyl thiophene (P3HT) organic semiconductor surface. A supplementary nonionic hydrophilic polymer is used as a blocking agent preventing nonspecific interactions and allowing a better orientation of the antibodies immobilized onto the P3HT surface. The whole biomolecule immobilization procedure does not require any pretreatment of the organic semiconductor surface, and the whole functionalization process is completed in less than 30 min. Surface plasmon resonance (SPR) measurements were performed to assess the amount of biomolecules physisorbed onto the P3HT and to evaluate the CRP binding proprieties of the deposited anti-CRP layer. A partial surface coverage of about 23 % of adsorbed antibody molecules was found to most efficiently sense the CRP. The electrical performance of the EGOFET immunosensor was comparable to that of a bare P3HT EGOFET device, and the obtained CRP calibration curve was linear over six orders of magnitude (from 4 pM to 2 μM). The relative standard deviation of the individual calibration points, measured on immunosensors fabricated on different chips, ranged between 1 and 14 %, and a detection limit of 2 pM (220 ng/L) was established. The novel electronic immunosensor is compatible with low-cost fabrication procedures and was successfully employed for the detection of the CRP biomarker in the clinically relevant matrix serum. Graphical abstract Schematic of the EGOFET immunosensor for CRP detection. The anti-CRP monoclonal antibody layer is physisorbed on the P3HT organic semiconductor and the CRP is directly measured by a label-free electronic EGOFET transducer.

Entities:  

Keywords:  C-reactive protein; Electrolyte-gated organic field-effect transistor; Immunosensor; Label-free electronic detection

Mesh:

Substances:

Year:  2016        PMID: 27032409     DOI: 10.1007/s00216-016-9502-3

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  8 in total

1.  Extended Solution Gate OFET-based Biosensor for Label-free Glial Fibrillary Acidic Protein Detection with Polyethylene Glycol-Containing Bioreceptor Layer.

Authors:  Jian Song; Jennifer Dailey; Hui Li; Hyun-June Jang; Pengfei Zhang; Jeff Tza-Huei Wang; Allen D Everett; Howard E Katz
Journal:  Adv Funct Mater       Date:  2017-03-23       Impact factor: 18.808

Review 2.  Sensors and Biosensors for C-Reactive Protein, Temperature and pH, and Their Applications for Monitoring Wound Healing: A Review.

Authors:  Pietro Salvo; Valentina Dini; Arno Kirchhain; Agata Janowska; Teresa Oranges; Andrea Chiricozzi; Tommaso Lomonaco; Fabio Di Francesco; Marco Romanelli
Journal:  Sensors (Basel)       Date:  2017-12-19       Impact factor: 3.576

Review 3.  Electrochemical sensing: A prognostic tool in the fight against COVID-19.

Authors:  Sharda Kotru; Martin Klimuntowski; Hashim Ridha; Zakir Uddin; Ali A Askhar; Gurmit Singh; Matiar M R Howlader
Journal:  Trends Analyt Chem       Date:  2021-01-23       Impact factor: 14.908

Review 4.  Micro- and nanosensors for detecting blood pathogens and biomarkers at different points of sepsis care.

Authors:  Alejandra Alba-Patiño; Andreu Vaquer; Enrique Barón; Steven M Russell; Marcio Borges; Roberto de la Rica
Journal:  Mikrochim Acta       Date:  2022-01-26       Impact factor: 5.833

5.  Design of a Portable Microfluidic Platform for EGOT-Based in Liquid Biosensing.

Authors:  Matteo Segantini; Matteo Parmeggiani; Alberto Ballesio; Gianluca Palmara; Francesca Frascella; Simone Luigi Marasso; Matteo Cocuzza
Journal:  Sensors (Basel)       Date:  2022-01-26       Impact factor: 3.576

6.  Electrochemical and X-ray Photoelectron Spectroscopy Surface Characterization of Interchain-Driven Self-Assembled Monolayer (SAM) Reorganization.

Authors:  Angelo Tricase; Anna Imbriano; Nicoletta Ditaranto; Eleonora Macchia; Rosaria Anna Picca; Davide Blasi; Luisa Torsi; Paolo Bollella
Journal:  Nanomaterials (Basel)       Date:  2022-03-04       Impact factor: 5.076

Review 7.  Recent Advances in Skin Chemical Sensors.

Authors:  Benoît Piro; Giorgio Mattana; Vincent Noël
Journal:  Sensors (Basel)       Date:  2019-10-10       Impact factor: 3.576

8.  Electrically Switchable Film Structure of Conjugated Polymer Composites.

Authors:  Kamil Awsiuk; Paweł Dąbczyński; Mateusz M Marzec; Jakub Rysz; Ellen Moons; Andrzej Budkowski
Journal:  Materials (Basel)       Date:  2022-03-17       Impact factor: 3.623

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.