Literature DB >> 27031877

Dopant-Assisted Positive Photoionization Ion Mobility Spectrometry Coupled with Time-Resolved Thermal Desorption for On-Site Detection of Triacetone Triperoxide and Hexamethylene Trioxide Diamine in Complex Matrices.

Dandan Jiang1,2, Liying Peng1,2, Meng Wen1,2, Qinghua Zhou1,2, Chuang Chen1, Xin Wang1, Wendong Chen1,2, Haiyang Li1.   

Abstract

Peroxide explosives, such as triacetone triperoxide (TATP) and hexamethylene trioxide diamine (HMTD), were often used in the terrorist attacks due to their easy synthesis from readily starting materials. Therefore, an on-site detection method for TATP and HMTD is urgently needed. Herein, we developed a stand-alone dopant-assisted positive photoionization ion mobility spectrometry (DAPP-IMS) coupled with time-resolved thermal desorption introduction for rapid and sensitive detection of TATP and HMTD in complex matrices, such as white solids, soft drinks, and cosmetics. Acetone was chosen as the optimal dopant for better separation between reactant ion peaks and product ion peaks as well as higher sensitivity, and the limits of detection (LODs) of TATP and HMTD standard samples were 23.3 and 0.2 ng, respectively. Explosives on the sampling swab were thermally desorbed and carried into the ionization region dynamically within 10 s, and the maximum released concentration of TATP or HMTD could be time-resolved from the matrix interference owing to the different volatility. Furthermore, with the combination of the fast response thermal desorber (within 0.8 s) and the quick data acquisition software to DAPP-IMS, two-dimensional data related to drift time (TATP: 6.98 ms, K0 = 2.05 cm(2) V(-1) s(-1); HMTD: 9.36 ms, K0 = 1.53 cm(2) V(-1) s(-1)) and desorption time was obtained for TATP and HMTD, which is beneficial for their identification in complex matrices.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27031877     DOI: 10.1021/acs.analchem.5b04830

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Ultra-Fast Polarity Switching, Non-Radioactive Drift Tube for the Miniaturization of Drift-Time Ion Mobility Spectrometer.

Authors:  Lingfeng Li; Hao Gu; Yanzhen Lv; Yunjing Zhang; Xingli He; Peng Li
Journal:  Sensors (Basel)       Date:  2022-06-27       Impact factor: 3.847

2.  Reactions of Organic Peroxides with Alcohols in Atmospheric Pressure Chemical Ionization-the Pitfalls of Quantifying Triacetone Triperoxide (TATP).

Authors:  Kevin Colizza; Alexander Yevdokimov; Lindsay McLennan; James L Smith; Jimmie C Oxley
Journal:  J Am Soc Mass Spectrom       Date:  2017-11-07       Impact factor: 3.109

3.  Improved analytical performance of photoionization ion mobility spectrometry for the rapid detection of organophosphorus pesticides using K 0 patterns with multiple reactant ions.

Authors:  Qinghua Zhou; Bin Wang; Jia Li; Zanhui Jin; Haiyang Li; Jinyuan Chen
Journal:  RSC Adv       Date:  2018-05-16       Impact factor: 3.361

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.