Literature DB >> 27030296

Circle of Willis Collateral During Temporary Internal Carotid Artery Occlusion I: Observations From Digital Subtraction Angiography.

Stephen P Lownie1, Ramiro Larrazabal2, Maximilian K Kole3.   

Abstract

INTRODUCTION: Impaired collateral circulation can lead to stroke during carotid endarterectomy. Carotid stump pressure (CSP) is used as a surrogate measure of collateral flow. The objective was to determine whether anatomical features obtained from digital subtraction angiography correlate with CSP during temporary internal carotid artery occlusion. The second objective was to use these features in combination to predict CSP.
METHODS: Digital subtraction angiographies from 102 patients obtained before endarterectomy were reviewed for anatomical variables including: degree of ipsilateral and contralateral carotid artery stenosis; patency of the anterior communicating artery; presence of cross-flow into ipsilateral middle cerebral artery branches; and size (< or ≥1 mm calibre) of the ipsilateral proximal anterior cerebral (A1), the contralateral A1, and the ipsilateral posterior communicating arteries. At surgery, systemic mean arterial pressure (MAP) and CSP were recorded. Multiple regression analysis was used to assess for anatomical features significantly associated with CSP. A "predicted CSP" equation was applied to 54 subsequent patients and correlated with measured CSP.
RESULTS: Variables correlating with CSP included MAP (p=0.001); the presence of severe contralateral carotid stenosis (p=0.002); patency of the anterior communicating artery (p=0.013); and the size of the contralateral A1 segment (p=0.029). Angiographic cross-flow, ipsilateral A1 size, and ipsilateral posterior communicating artery size were not significant. Predicted CSP correlated significantly with measured CSP (p<0.0001; R 2=0.34).
CONCLUSIONS: Anatomical features and systemic MAP are associated with carotid stump pressure during internal carotid artery occlusion and account for a significant amount of its variation.

Entities:  

Keywords:  Carotid stenosis; carotid endarterectomy; carotid stump pressure; cerebral collateral circulation; circle of Willis

Mesh:

Year:  2016        PMID: 27030296     DOI: 10.1017/cjn.2016.9

Source DB:  PubMed          Journal:  Can J Neurol Sci        ISSN: 0317-1671            Impact factor:   2.104


  2 in total

1.  Correlation between Carotid Stenosis Degree and Blood Pressure Variability in Patients with Carotid Stenosis.

Authors:  Junli Nie; Liang Hou; Baozhen Tan
Journal:  Comput Math Methods Med       Date:  2022-05-21       Impact factor: 2.809

2.  Carotid Stump Pressure and Contralateral Internal Carotid Stenosis Ratio During Carotid Endarterectomies: 1D-0D Hemodynamic Simulation of Cerebral Perfusion.

Authors:  Sohei Matsuura; Toshio Takayama; Changyoung Yuhn; Marie Oshima; Takuro Shirasu; Takafumi Akai; Toshihiko Isaji; Katsuyuki Hoshina
Journal:  Ann Vasc Dis       Date:  2021-03-25
  2 in total