Literature DB >> 27029283

Does Bedside Sonography Effectively Identify Nasogastric Tube Placements in Pediatric Critical Care Patients?

Yunus Oktay Atalay1, Ramazan Aydin2, Omer Ertugrul3, Selim Baris Gul4, Ahmet Veysel Polat5, Muhammet Sukru Paksu6.   

Abstract

BACKGROUND: A nasogastric tube (NGT) insertion is a common procedure in intensive care units, with some serious complications that result from the malposition of the NGT tip. This pilot study was designed to investigate the efficiency of ultrasound in verifying correct NGT placement and to compare these results with radiographic findings.
MATERIALS AND METHODS: This was a single-center, double-blind prospective study of patients who had received an NGT in the pediatric critical care unit. Twenty-one patients aged 1 month to 18 years were included in this study. All NGTs were inserted by the same critical care physician. After insertion, the physician first confirmed NGT placement by the auscultation of the epigastrium following the insufflation of air. Confirmation was supplemented with an abdominal radiograph. A radiologist who was unaware of the radiographic findings performed bedside sonography on all patients and verified the location of the NGTs. The findings from these 2 physicians were then compared.
RESULTS: NGTs were inserted without any complications, and none of the NGTs were positioned in the respiratory tract in any of the patients. All NGT tips were visualized by radiography and sonography with a sensitivity of 100%.
CONCLUSION: Bedside sonography performed by a radiologist is an effective and sensitive diagnostic procedure for confirming the correct NGT position in patients in the pediatric critical care unit.

Entities:  

Keywords:  enteral nutrition; intensive care units; nasogastric tube; patient safety; pediatrics; radiography; ultrasonography

Mesh:

Year:  2016        PMID: 27029283     DOI: 10.1177/0884533616639401

Source DB:  PubMed          Journal:  Nutr Clin Pract        ISSN: 0884-5336            Impact factor:   3.080


  3 in total

1.  Bedside ultrasonography for the confirmation of gastric tube placement in the neonate.

Authors:  Yunus Oktay Atalay; Ahmet Veysel Polat; Elif Ozyazici Ozkan; Leman Tomak; Canan Aygun; Joseph Drew Tobias
Journal:  Saudi J Anaesth       Date:  2019 Jan-Mar

2.  Rapid positioning of nasogastric tube by ultrasound in COVID-19 patients.

Authors:  Anyu Qian; Shanxiang Xu; Xiao Lu; Luping Tang; Mao Zhang; Xiao Chen
Journal:  Crit Care       Date:  2020-09-22       Impact factor: 9.097

3.  Verifying the placement and length of feeding tubes in canine and feline neonates.

Authors:  Etienne Furthner; Mariusz Paweł Kowalewski; Paul Torgerson; Iris Margaret Reichler
Journal:  BMC Vet Res       Date:  2021-06-07       Impact factor: 2.741

  3 in total