Literature DB >> 27027626

Repeatability of Keratometry Measurements Obtained With Three Topographers in Keratoconic and Normal Corneas.

Emmanuel Guilbert, Alain Saad, Maud Elluard, Alice Grise-Dulac, Hélène Rouger, Damien Gatinel.   

Abstract

PURPOSE: To assess the repeatability of the corneal topography functions of Orbscan II (Bausch & Lomb, Rochester, NY), OPD-Scan III (Nidek, Gamagori, Japan), and iTrace (Tracey Technologies, Houston, TX) in keratoconic eyes and in a control group of normal patients.
METHODS: In this prospective cohort study, patients were recruited between November 2011 and May 2012. Measurements were performed with a combined Placido-scanning slit system (Orbscan II) and two combined Placido-aberrometer systems (OPD-Scan III and iTrace). Repeatability limit and intraclass correlation coefficients (ICCs) of keratometric readings were calculated.
RESULTS: Fifty-nine keratoconic eyes of 34 patients and 54 normal eyes of 27 patients were included. Three groups were evaluated: all stage I-IV keratoconic eyes (59 eyes), a subgroup consisting of stage I-II keratoconic eyes (41 eyes), and normal eyes (54 eyes). For almost all parameters studied, the repeatability limit was higher in the two groups of keratoconic eyes compared to normal eyes with all three topographers, indicating lower repeatability. For the maximum keratometry measurement, repeatability limit was 1.73, 1.49, and 1.41 diopters (D) in the stage I-IV keratoconic eyes group, 1.11, 1.02, and 0.98 D in the stage I-II keratoconic eyes group, and 0.61, 0.37, and 1.02 D in the normal eyes group with Orbscan II, OPD-Scan III, and iTrace, respectively.
CONCLUSIONS: Topographies performed in keratoconic eyes are less repeatable than those performed in normal eyes. Threshold values of keratometric changes used to ascertain keratoconus progression should be carefully considered. Caution should be taken when interpreting the topographies of such patients. The higher variability should be taken into account before performing any treatment. Copyright 2016, SLACK Incorporated.

Entities:  

Mesh:

Year:  2016        PMID: 27027626     DOI: 10.3928/1081597X-20160113-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  7 in total

1.  Corneal power measurement with a new aberrometer/corneal topographer in eyes after small incision lenticule extraction for myopia.

Authors:  Chao Pan; Weina Tan; Yanjun Hua; Xiaohua Lei
Journal:  Int Ophthalmol       Date:  2019-05-27       Impact factor: 2.031

2.  Scanning-slit topography in patients with keratoconus.

Authors:  László Módis; Gábor Németh; Eszter Szalai; Zsuzsa Flaskó; Berthold Seitz
Journal:  Int J Ophthalmol       Date:  2017-11-18       Impact factor: 1.779

3.  Analysis of Age, Gender, and Refractive Error-Related Changes of the Anterior Corneal Surface Parameters Using Oculus Keratograph Topography.

Authors:  Nasrin Moghadas Sharif; Negareh Yazdani; Leila Shahkarami; Hadi Ostadi Moghaddam; Asieh Ehsaei
Journal:  J Curr Ophthalmol       Date:  2020-07-04

4.  Corneal parameters 18 Months following collagen cross-linkage treatment (CXL) for keratoconus in western Saudi Arabia: A prospective cohort study.

Authors:  Ashjan Bamahfouz; Serene Jouhargy; Ahmed Basheikh; Nawaf Alqahtani; Yaser Elhams; Ayat Aldosari; Faisal Khattab; Ensa Alkhoutani; Khadija Alfaqih
Journal:  Ann Med Surg (Lond)       Date:  2020-09-09

5.  OPD scan III accuracy: Topographic and aberrometric indices after accelerated corneal cross-linking.

Authors:  Soheila Asgari; Hassan Hashemi
Journal:  J Curr Ophthalmol       Date:  2017-11-14

Review 6.  Machine Learning Algorithms to Detect Subclinical Keratoconus: Systematic Review.

Authors:  Howard Maile; Ji-Peng Olivia Li; Daniel Gore; Marcello Leucci; Padraig Mulholland; Scott Hau; Anita Szabo; Ismail Moghul; Konstantinos Balaskas; Kaoru Fujinami; Pirro Hysi; Alice Davidson; Petra Liskova; Alison Hardcastle; Stephen Tuft; Nikolas Pontikos
Journal:  JMIR Med Inform       Date:  2021-12-13

7.  Quantitative interocular comparison of total corneal surface area and corneal diameter in patients with highly asymmetric keratoconus.

Authors:  François-Xavier Crahay; Guillaume Debellemanière; Stephan Tobalem; Wassim Ghazal; Sarah Moran; Damien Gatinel
Journal:  Sci Rep       Date:  2022-03-11       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.