Literature DB >> 27027398

Titanium: a review on exposure, release, penetration, allergy, epidemiology, and clinical reactivity.

Simon W Fage1, Joris Muris2, Stig S Jakobsen3, Jacob P Thyssen4.   

Abstract

Exposure to titanium (Ti) from implants and from personal care products as nanoparticles (NPs) is common. This article reviews exposure sources, ion release, skin penetration, allergenic effects, and diagnostic possibilities. We conclude that human exposure to Ti mainly derives from dental and medical implants, personal care products, and foods. Despite being considered to be highly biocompatible relative to other metals, Ti is released in the presence of biological fluids and tissue, especially under certain circumstances, which seem to be more likely with regard to dental implants. Although most of the studies reviewed have important limitations, Ti seems not to penetrate a competent skin barrier, either as pure Ti, alloy, or as Ti oxide NPs. However, there are some indications of Ti penetration through the oral mucosa. We conclude that patch testing with the available Ti preparations for detection of type IV hypersensitivity is currently inadequate for Ti. Although several other methods for contact allergy detection have been suggested, including lymphocyte stimulation tests, none has yet been generally accepted, and the diagnosis of Ti allergy is therefore still based primarily on clinical evaluation. Reports on clinical allergy and adverse events have rarely been published. Whether this is because of unawareness of possible adverse reactions to this specific metal, difficulties in detection methods, or the metal actually being relatively safe to use, is still unresolved.
© 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  contact allergy; corrosion; dermatitis; hypersensitivity; lymphocyte transformation test; patch test; penetration; release; titanium; toxicity

Mesh:

Substances:

Year:  2016        PMID: 27027398     DOI: 10.1111/cod.12565

Source DB:  PubMed          Journal:  Contact Dermatitis        ISSN: 0105-1873            Impact factor:   6.600


  28 in total

1.  [Pseudo allergic reaction to metal implant].

Authors:  A Guertler; P Thomas; T Herzinger
Journal:  Hautarzt       Date:  2018-10       Impact factor: 0.751

2.  Characterization of foreign materials in paraffin-embedded pathological specimens using in situ multi-elemental imaging with laser spectroscopy.

Authors:  Benoit Busser; Samuel Moncayo; Florian Trichard; Vincent Bonneterre; Nicole Pinel; Frédéric Pelascini; Philippe Dugourd; Jean-Luc Coll; Michel D'Incan; Julie Charles; Vincent Motto-Ros; Lucie Sancey
Journal:  Mod Pathol       Date:  2017-11-17       Impact factor: 7.842

Review 3.  [Compatibility and allergies of osteosynthesis materials].

Authors:  M Thomsen; P Thomas
Journal:  Unfallchirurg       Date:  2017-02       Impact factor: 1.000

Review 4.  Immunological reaction to magnesium-based implants for orthopedic applications. What do we know so far? A systematic review on in vivo studies.

Authors:  Omer Suljevic; Stefan F Fischerauer; Annelie M Weinberg; Nicole G Sommer
Journal:  Mater Today Bio       Date:  2022-06-09

5.  Advances in Laser Additive Manufacturing of Ti-Nb Alloys: From Nanostructured Powders to Bulk Objects.

Authors:  Margarita A Khimich; Konstantin A Prosolov; Tatiana Mishurova; Sergei Evsevleev; Xavier Monforte; Andreas H Teuschl; Paul Slezak; Egor A Ibragimov; Alexander A Saprykin; Zhanna G Kovalevskaya; Andrey I Dmitriev; Giovanni Bruno; Yurii P Sharkeev
Journal:  Nanomaterials (Basel)       Date:  2021-04-29       Impact factor: 5.076

6.  Biocompatibility and Inflammatory Potential of Titanium Alloys Cultivated with Human Osteoblasts, Fibroblasts and Macrophages.

Authors:  Jana Markhoff; Martin Krogull; Christian Schulze; Christian Rotsch; Sandra Hunger; Rainer Bader
Journal:  Materials (Basel)       Date:  2017-01-10       Impact factor: 3.623

7.  The Secretory Response of Rat Peritoneal Mast Cells on Exposure to Mineral Fibers.

Authors:  Violetta Borelli; Elisa Trevisan; Vita Francesca; Giuliano Zabucchi
Journal:  Int J Environ Res Public Health       Date:  2018-01-10       Impact factor: 3.390

8.  A retrospective study on titanium sensitivity: Patch test materials and manifestations.

Authors:  Niels P J de Graaf; Albert J Feilzer; Cees J Kleverlaan; Hetty Bontkes; Sue Gibbs; Thomas Rustemeyer
Journal:  Contact Dermatitis       Date:  2018-05-24       Impact factor: 6.600

9.  Patch test-relevant concentrations of metal salts cause localized cytotoxicity, including apoptosis, in skin ex vivo.

Authors:  Yan Zhang; Niels P J de Graaf; Rosalien Veldhuizen; Sanne Roffel; Sander W Spiekstra; Thomas Rustemeyer; Cees J Kleverlaan; Albert J Feilzer; Hetty Bontkes; Dongmei Deng; Susan Gibbs
Journal:  Contact Dermatitis       Date:  2021-08-15       Impact factor: 6.419

Review 10.  The Roles of Autophagy and the Inflammasome during Environmental Stress-Triggered Skin Inflammation.

Authors:  Rong-Jane Chen; Yu-Hsuan Lee; Ya-Ling Yeh; Ying-Jan Wang; Bour-Jr Wang
Journal:  Int J Mol Sci       Date:  2016-12-09       Impact factor: 5.923

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.