Literature DB >> 27027101

3D fitting accuracy evaluation of CAD/CAM copings - comparison with spacer design settings.

Philippe Boitelle, Laurent Tapie, Bernardin Mawussi, Olivier Fromentin.   

Abstract

OBJECTIVES: The accuracy of computer-aided design/computer- aided manufacturing (CAD/CAM) systems is linked to their technical characteristics and reliability for manufacturing the restoration designed. The aim of this study was to compare the accuracy of fit of zirconia copings manufactured with different CAD/CAM systems and their capacity to conform to pre-established spacer design settings.
METHODS: Sixty zirconia copings were manufactured by three CAD/CAM systems, with their spacers set as recommended by their manufacturer on occlusal, axial, and marginal surfaces. The 3D triple-scan optical technique was used to obtain a fit mapping and to analyze the marginal and axial accuracy of fit. The reliability of the 3D measurement method was estimated using intraclass correlation and repeatability coefficients. The preparation coping interface width results were statistically analyzed using non-parametric analysis (Kruskal-Wallis, one-way ANOVA, and Wilcoxon signedrank tests) (P < 0.05).
RESULTS: The repeatability coefficient was 6, 8, and 15 μm for axial, marginal, and occlusal interface width measurements, respectively. For the three systems tested, no differences were found in the marginal area of the copings studied, with a mean fitting accuracy ranging from 54.3 to 66.6 μm interface width. Statistically significant differences between groups were observed for the fitting accuracy measured in axial and occlusal areas. With the spacers set in the different areas, mean fit measurements of the zirconia copings were significantly larger, with an increased fit width ranging from 30 to 73 μm. SIGNIFICANCE: The three CAD/CAM systems evaluated allowed similar marginal accuracy but failed to reproduce the pre-established spacer parameters, with larger spacing showing throughout.

Mesh:

Substances:

Year:  2016        PMID: 27027101

Source DB:  PubMed          Journal:  Int J Comput Dent        ISSN: 1463-4201            Impact factor:   1.883


  4 in total

1.  Evaluation of the marginal and internal fit of CAD/CAM crowns designed using three different dental CAD programs: a 3-dimensional digital analysis study.

Authors:  Ra'fat I Farah; Bandar Alresheedi
Journal:  Clin Oral Investig       Date:  2022-09-14       Impact factor: 3.606

Review 2.  Fit of tooth-supported zirconia single crowns-A systematic review of the literature.

Authors:  Walaa Magdy Ahmed; Batoul Shariati; Arwa Z Gazzaz; Mohammed E Sayed; Ricardo M Carvalho
Journal:  Clin Exp Dent Res       Date:  2020-09-03

3.  A Comparative Study of Additive and Subtractive Manufacturing Techniques for a Zirconia Dental Product: An Analysis of the Manufacturing Accuracy and the Bond Strength of Porcelain to Zirconia.

Authors:  Joon-Mo Moon; Chang-Sub Jeong; Hee-Jeong Lee; Ji-Myung Bae; Eun-Joo Choi; Sung-Tae Kim; Young-Bum Park; Seung-Han Oh
Journal:  Materials (Basel)       Date:  2022-08-05       Impact factor: 3.748

4.  Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model.

Authors:  Yeon Jang; Ji-Young Sim; Jong-Kyoung Park; Woong-Chul Kim; Hae-Young Kim; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2018-10-22       Impact factor: 1.904

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.