Literature DB >> 27023108

Swept-Source Optical Coherence Tomography Angio™ (Topcon Corp, Japan): Technology Review.

Paulo E Stanga, Emmanouil Tsamis, Alessandro Papayannis, Francesco Stringa, Tim Cole, Assad Jalil.   

Abstract

Optical coherence tomography (OCT) angiography (OCTA) is a novel, noninvasive, three-dimensional imaging technique that allows for the visualization of intravascular flow in the microvasculature. Swept-source OCT technology utilizes longer-wavelength infrared light than conventional spectral-domain OCT. This enables improved penetration into tissue and imaging through optical opacities and is invisible to the subject. Topcon has recently developed an innovative OCTA algorithm, OCTARA (OCTA Ratio Analysis), which benefits from being paired with swept-source OCT. OCTARA aims to provide improved detection sensitivity of low blood flow and reduced motion artifacts without compromising axial resolution. In this chapter, we describe the implementation of OCTARA with swept-source OCT technology, the technical specifications of acquisition (e.g. the number of scans, area of examination field, etc.) along with the algorithm's function and principles for analysis of B-scan data to achieve angiographic visualization. Examples of OCTA scans performed using the OCTARA algorithm and a comparison of these scans with images obtained using other technologies are also presented.
© 2016 S. Karger AG, Basel.

Mesh:

Year:  2016        PMID: 27023108     DOI: 10.1159/000442771

Source DB:  PubMed          Journal:  Dev Ophthalmol        ISSN: 0250-3751


  55 in total

1.  Foveal and parafoveal choroidal thickness pattern measuring by swept source optical coherence tomography.

Authors:  Pear Pongsachareonnont; Thanapong Somkijrungroj; Buravej Assavapongpaiboon; Theerada Chitamara; Maytavee Chuntarapas; Disorn Suwajanakorn
Journal:  Eye (Lond)       Date:  2019-04-08       Impact factor: 3.775

2.  Optical Coherence Tomography Angiography Compared With Optical Coherence Tomography Macular Measurements for Detection of Glaucoma.

Authors:  Kelvin H Wan; Alexander K N Lam; Christopher Kai-Shun Leung
Journal:  JAMA Ophthalmol       Date:  2018-08-01       Impact factor: 7.389

3.  High dynamic range optical coherence tomography angiography (HDR-OCTA).

Authors:  Xiang Wei; Tristan T Hormel; Shaohua Pi; Yukun Guo; Yifan Jian; Yali Jia
Journal:  Biomed Opt Express       Date:  2019-06-24       Impact factor: 3.732

4.  A quantitative comparison of five optical coherence tomography angiography systems in clinical performance.

Authors:  Xin-Xin Li; Wei Wu; Hao Zhou; Jun-Jie Deng; Meng-Ya Zhao; Tian-Wei Qian; Chen Yan; Xun Xu; Su-Qin Yu
Journal:  Int J Ophthalmol       Date:  2018-11-18       Impact factor: 1.779

5.  Microvasculature of the Optic Nerve Head and Peripapillary Region in Patients With Primary Open-Angle Glaucoma.

Authors:  Rafaella Nascimento E Silva; Carolina A Chiou; Mengyu Wang; Haobing Wang; Marissa K Shoji; Jonathan C Chou; Erica E D'Souza; Scott H Greenstein; Stacey C Brauner; Milton R Alves; Louis R Pasquale; Lucy Q Shen
Journal:  J Glaucoma       Date:  2019-04       Impact factor: 2.503

6.  Multimodality Imaging Approach for Combined Central Retinal Vein and Artery Occlusion: The Role of Optical Coherence Tomography Angiography.

Authors:  Marta Díez-Sotelo; Maximino Abraldes; Francisco Gómez-Ulla
Journal:  Case Rep Ophthalmol       Date:  2019-12-04

7.  Features of the choriocapillaris on four different optical coherence tomography angiography devices.

Authors:  Cheolmin Yun; Ki Tae Nam; Seoyeon Park; Soon-Young Hwang; Jaeryung Oh
Journal:  Int Ophthalmol       Date:  2019-09-28       Impact factor: 2.031

Review 8.  Optical coherence tomography angiography (OCTA) flow speed mapping technology for retinal diseases.

Authors:  Malvika Arya; Ramy Rashad; Osama Sorour; Eric M Moult; James G Fujimoto; Nadia K Waheed
Journal:  Expert Rev Med Devices       Date:  2018-11-22       Impact factor: 3.166

9.  Incidence of Fellow Eye Involvement in Patients With Unilateral Exudative Age-Related Macular Degeneration.

Authors:  Yasuo Yanagi; Aditi Mohla; Shu Yen Lee; Ranjana Mathur; Choi Mun Chan; Ian Yeo; Tien Yin Wong; Chui Ming Gemmy Cheung
Journal:  JAMA Ophthalmol       Date:  2018-08-01       Impact factor: 7.389

10.  Ganglion cell layer thickening in patients suffering from Obstructive Sleep Apnea-Hypopnea syndrome with long Mean Apnea-Hypopnea Duration during sleep.

Authors:  Evangelia Chalkiadaki; Konstantinos Andreanos; Efthymios Karmiris; Chrysoula Florou; Xanthi Tsiafaki; Anastasia Amfilochiou; Ilias Georgalas; Chrysanthi Koutsandrea; Dimitrios Papaconstantinou
Journal:  Int Ophthalmol       Date:  2020-11-17       Impact factor: 2.031

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.