Lúcio Honório de Carvalho Júnior1, Luiz Fernando Machado Soares2, Matheus Braga Jacques Gonçalves2, Tiago Pinto de Oliveira Gomes3, Juraci Rosa de Oliveira4, Mauro Gualberto Coelho5, Rogério Luciano Dos Santos6, Marco Antônio Percope de Andrade7, Guilherme de Lima E Silva8, Eduardo Nilo Vasconcelos Novais9.
Abstract
UNLABELLED: To evaluate whether, by using an arthropump (irrigation equipment with pressure sensor), pneumatic tourniquet use could interfere with the duration of surgery, recovery of movement and joint volume in patients who underwent knee videoarthroscopy for partial meniscectomy.Entities:
Keywords: Arthroscopy; Surgery; Tourniquets
Year: 2015 PMID: 27022588 PMCID: PMC4799072 DOI: 10.1016/S2255-4971(15)30429-8
Source DB: PubMed Journal: Rev Bras Ortop ISSN: 2255-4971
Comparison between groups 1 and 2 and the respective p values.
| Group 1 (without tourniquet) | Group 2 (with tourniquet) | p value | |
|---|---|---|---|
| Age in years | 49.1765 | 49.26 | 0.9766 |
| Duration of surgery in minutes | 21.2941 | 21.7115 | 0.8528 |
| Difference in range of motion between the knees in degrees | 8.70 | 8.36 | 0.8829 |
| Difference in perimeter between the knees in cm | 0.2686 | 0.2788 | 0.9669 |