Diagnostic performance of a semiconductor gamma-camera system as studied by multicenter registry.

Taishiro Chikamori1, Kenji Goto2, Satoshi Hida3, Masao Miyagawa4, Hayato Ishimura4, Kenji Uchida5, Takaya Fukuyama6, Teruhito Mochizuki4, Akira Yamashina3.   

Abstract

BACKGROUND: Despite the introduction of the novel cadmium-zinc-telluride (CZT) single-photon emission computed tomography (SPECT) in Japan; its diagnostic value in clinical practice remains largely unknown.
METHODS: The Semiconductor SPECT Study group is a multicenter Japanese registry which registered 1000 patients to evaluate the diagnostic utility of the CZT camera system (Discovery NM530c; GE Healthcare, Haifa, Israel). The patients underwent stress myocardial SPECT and coronary angiography within a 3-month interval. A significant stenosis was defined as ≥75% diameter narrowing based on the American Heart Association classification.
RESULTS: Technetium (99mTc) radiotracer (555-1110MBq) was used in 71% and thallium-201 (201Tl) (74-148MBq) in 29%. The scan times with 99mTc-radiotracer were 5-10min for stress and 3-10min for rest, whereas those with 201Tl were 5-9min for stress and 8-10min for rest. To detect individual coronary stenosis, the respective sensitivities, specificities, and accuracies were 74%, 85%, and 81% for left anterior descending coronary artery (LAD) stenosis, 76%, 89%, and 85% for left circumflex stenosis, and 72%, 86%, and 82% for right coronary artery stenosis. However, 66% sensitivity and 91% specificity for LAD stenosis were observed with 99mTc-radiotracer, whereas 88% sensitivity and 63% specificity were found with 201Tl.
CONCLUSIONS: The novel CZT SPECT system facilitated a short scan time with reduced radiotracer dose, yielding an acceptable diagnostic performance for angiographical coronary artery disease, although the low sensitivity for LAD detection with 99mTc-radiotracer needs to be refined.
Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Cadmium–zinc–telluride camera; Coronary angiography; Coronary artery disease; Diagnosis; Single-photon emission computed tomography

Mesh:

Substances:

Year:  2016        PMID: 27021428     DOI: 10.1016/j.jjcc.2016.02.020

Source DB:  PubMed          Journal:  J Cardiol        ISSN: 0914-5087            Impact factor:   3.159


  1 in total

1.  Synergistic prognostication of left ventricular hypertrophy and three-dimensional mechanical dyssynchrony in heart failure.

Authors:  Takahiro Doi; Tomoaki Nakata; Satoshi Yuda; Akiyoshi Hashimoto
Journal:  ESC Heart Fail       Date:  2020-01-21
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.