Literature DB >> 27021351

About the numerical robustness of biomedical benchmark cases: Interlaboratory FDA's idealized medical device.

Vladeta Zmijanovic1, Simon Mendez1, Vincent Moureau2, Franck Nicoud1.   

Abstract

The need for reliable approaches in numerical simulations stands out as a critical issue for the development and optimization of cardiovascular biomedical devices. This led the US Food and Drug Administration to undertake a programme of validation of computational fluid dynamics methods for transitional and turbulent flows. In the current investigation, large-eddy simulation is used to simulate the flow in the first benchmark medical device, and results are confronted to the existing laboratory experiments. This idealized medical device has the particularity to feature transition to turbulence after a sudden expansion. The effects of numerical parameters and low-level inlet perturbations are investigated. Results indicate a considerable impact of numerical aspects on the prediction of the location of the transition to turbulence. The study also demonstrates that injecting small perturbations at the inflow greatly improves the streamwise velocity estimation in the transition region and substantially contributes to the robustness of the flow statistical data.
Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

Keywords:  experimental-numerical validation; flow sensitivity; hemodynamics; large-eddy-simulation; perturbations; turbulence

Mesh:

Year:  2016        PMID: 27021351     DOI: 10.1002/cnm.2789

Source DB:  PubMed          Journal:  Int J Numer Method Biomed Eng        ISSN: 2040-7939            Impact factor:   2.747


  4 in total

1.  Speech can produce jet-like transport relevant to asymptomatic spreading of virus.

Authors:  Manouk Abkarian; Simon Mendez; Nan Xue; Fan Yang; Howard A Stone
Journal:  Proc Natl Acad Sci U S A       Date:  2020-09-25       Impact factor: 11.205

2.  The nested block preconditioning technique for the incompressible Navier-Stokes equations with emphasis on hemodynamic simulations.

Authors:  Ju Liu; Weiguang Yang; Melody Dong; Alison L Marsden
Journal:  Comput Methods Appl Mech Eng       Date:  2020-05-27       Impact factor: 6.756

3.  Efficacy of the FDA nozzle benchmark and the lattice Boltzmann method for the analysis of biomedical flows in transitional regime.

Authors:  Kartik Jain
Journal:  Med Biol Eng Comput       Date:  2020-06-07       Impact factor: 2.602

4.  Assessing Changes in Airflow and Energy Loss in a Progressive Tracheal Compression Before and After Surgical Correction.

Authors:  Qiwei Xiao; Raul Cetto; Denis J Doorly; Alister J Bates; Jan N Rose; Charlotte McIntyre; Andrew Comerford; Gitta Madani; Neil S Tolley; Robert Schroter
Journal:  Ann Biomed Eng       Date:  2019-12-02       Impact factor: 3.934

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.