Literature DB >> 27017012

Feasibility of a Chest-worn accelerometer for physical activity measurement.

Joni H Zhang1, Duncan J Macfarlane2, Tanja Sobko1.   

Abstract

OBJECTIVES: A "proof-of-concept" study to examine the feasibility of wearing an Actigraph GT3X+ at the Chest (resembling a neck pendant) for physical activity measurement.
DESIGN: A convenience sample of 45 healthy adults (23 male, mean age 20.0±4.5 years) was included in data analysis.
METHODS: Participants simultaneously wore three GT3X+ accelerometers, on the Waist, Wrist, and Chest and completed 8 bouts of slow (.67, .89, 1.11m/s), average (1.33, 1.56, 1.78m/s) and fast (2.00, 2.22m/s) walking on a treadmill. Paired t-test, correlations and absolute percentage errors (APE) of accelerometer output (vector magnitude, VM) were computed for the key pairs: Waist-Wrist; and Waist-Chest.
RESULTS: The Wrist-site overestimated VM to a greater extent at all speeds in comparison to the Chest. Pearson's r correlations were weaker for Waist-Wrist (<.80) in comparison to the Waist-Chest (>.85). The APE's were much lower (i.e. higher agreement) for the Chest (9.23-15.5%) compared to the Wrist (19.7-54.9%). Participants also felt the Chest-site was more acceptable than the Waist-site.
CONCLUSIONS: PA measurements recorded by a Chest worn GT3X+ more closely resembled PA measurements recorded at the traditional Waist site than when compared to the Wrist site. When combined with high Chest site preference, the findings of our study suggest that the Chest is a feasible site for accelerometer wear. Copyright Â
© 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Actigraph; Activity monitors; Measurement; Objective monitoring; Treadmill; Wrist worn

Mesh:

Year:  2016        PMID: 27017012     DOI: 10.1016/j.jsams.2016.03.004

Source DB:  PubMed          Journal:  J Sci Med Sport        ISSN: 1878-1861            Impact factor:   4.319


  7 in total

1.  Relationship between patient-based scoring systems and the activity level of patients measured by wearable activity trackers in lumbar spine disease.

Authors:  Masahiro Inoue; Sumihisa Orita; Kazuhide Inage; Miyako Suzuki; Kazuki Fujimoto; Yasuhiro Shiga; Hirohito Kanamoto; Koki Abe; Hideyuki Kinoshita; Masaki Norimoto; Tomotaka Umimura; Takashi Sato; Masashi Sato; Masahiro Suzuki; Keigo Enomoto; Yawara Eguchi; Yasuchika Aoki; Tsutomu Akazawa; Yohei Kawasaki; Seiji Ohtori
Journal:  Eur Spine J       Date:  2019-06-03       Impact factor: 3.134

2.  Contrasting characteristics of daily physical activity in older adults by cancer history.

Authors:  Amal A Wanigatunga; Gillian K Gresham; Pei-Lun Kuo; Pablo Martinez-Amezcua; Vadim Zipunnikov; Sydney M Dy; Eleanor M Simonsick; Luigi Ferrucci; Jennifer A Schrack
Journal:  Cancer       Date:  2018-10-01       Impact factor: 6.860

3.  StraightenUp+: Monitoring of Posture during Daily Activities for Older Persons Using Wearable Sensors.

Authors:  Gabriela Cajamarca; Iyubanit Rodríguez; Valeria Herskovic; Mauricio Campos; Juan Carlos Riofrío
Journal:  Sensors (Basel)       Date:  2018-10-11       Impact factor: 3.576

4.  Comparison of the Activity Level of the Upper Limbs and Trunk in Patients with Low Back Pain Evaluated Using a Wearable Accelerometer: A Validation Study.

Authors:  Masahiro Inoue; Sumihisa Orita; Kazuhide Inage; Miyako Suzuki; Kazuki Fujimoto; Yasuhiro Shiga; Hirohito Kanamoto; Koki Abe; Hideyuki Kinoshita; Masaki Norimoto; Tomotaka Umimura; Takashi Sato; Masashi Sato; Masahiro Suzuki; Keigo Enomoto; Yawara Eguchi; Yasuchika Aoki; Tsutomu Akazawa; Seiji Ohtori
Journal:  Spine Surg Relat Res       Date:  2019-03-22

5.  Motion Assessment for Accelerometric and Heart Rate Cycling Data Analysis.

Authors:  Hana Charvátová; Aleš Procházka; Oldřich Vyšata
Journal:  Sensors (Basel)       Date:  2020-03-10       Impact factor: 3.576

Review 6.  Chest-Worn Inertial Sensors: A Survey of Applications and Methods.

Authors:  Mohammad Hasan Rahmani; Rafael Berkvens; Maarten Weyn
Journal:  Sensors (Basel)       Date:  2021-04-19       Impact factor: 3.576

Review 7.  Clinical Utility of Elosulfase Alfa in the Treatment of Morquio A Syndrome.

Authors:  Chung-Lin Lee; Chih-Kuang Chuang; Huei-Ching Chiu; Ru-Yi Tu; Yun-Ting Lo; Ya-Hui Chang; Shuan-Pei Lin; Hsiang-Yu Lin
Journal:  Drug Des Devel Ther       Date:  2022-01-10       Impact factor: 4.162

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.