Pavlina Ruzickova 1 , Patrick Burns 1 , Perrine Piat 1 , Martin G Frasch 2 , Guy Beauchamp 3 , Yvonne A Elce 1 . Show Affiliations »
Abstract
OBJECTIVE: To compare a knotless, barbed suture to standard suture using laparoscopic suturing methods in an ex vivo model of equine bladder repair. STUDY DESIGN: Cadaveric study. SAMPLE POPULATION: Equine cadaver bladders (n=42). METHODS: A 5-cm incision was created and repaired in a laparoscopic training box with 4 different suture materials. Groups 1 and 2 used 2-0 poliglecaprone and 2-0 glycomer knotless, barbed suture, respectively, placed using laparoscopic instruments. Groups 3 and 4 used 0 and 2-0 polyglyconate knotless, barbed suture, respectively, placed using an automated laparoscopic suturing device. All groups used a double-layer inverting pattern. Time for suture placement was recorded. Bladders were inflated with water and bursting strength pressures recorded, including a control group of intact bladders. Statistical analysis using a linear model and taking into account the unequal variances was followed by a post-hoc Tukey's test. Significance was set at P<.05. RESULTS: Bursting strength did not vary significantly between treatment groups, but was significantly decreased compared to the control group (P<.001). Time to place the sutures with the 2 automated suture device groups (groups 3 and 4) was significantly faster than those in which the suture was placed using laparoscopic needle holders and forceps (groups 1 and 2; P=.001). CONCLUSION: Knotless, barbed suture may be a viable alternative to standard suture material for laparoscopic closure of the urinary bladder in horses. Further cyclic and in vivo testing should be performed before use in clinical cases. © Copyright 2016 by The American College of Veterinary Surgeons.
OBJECTIVE: To compare a knotless, barbed suture to standard suture using laparoscopic suturing methods in an ex vivo model of equine bladder repair. STUDY DESIGN: Cadaveric study. SAMPLE POPULATION: Equine cadaver bladders (n=42). METHODS: A 5-cm incision was created and repaired in a laparoscopic training box with 4 different suture materials. Groups 1 and 2 used 2-0 poliglecaprone and 2-0 glycomer knotless, barbed suture, respectively, placed using laparoscopic instruments. Groups 3 and 4 used 0 and 2-0 polyglyconate knotless, barbed suture, respectively, placed using an automated laparoscopic suturing device. All groups used a double-layer inverting pattern. Time for suture placement was recorded. Bladders were inflated with water and bursting strength pressures recorded, including a control group of intact bladders. Statistical analysis using a linear model and taking into account the unequal variances was followed by a post-hoc Tukey's test. Significance was set at P<.05. RESULTS: Bursting strength did not vary significantly between treatment groups, but was significantly decreased compared to the control group (P<.001). Time to place the sutures with the 2 automated suture device groups (groups 3 and 4) was significantly faster than those in which the suture was placed using laparoscopic needle holders and forceps (groups 1 and 2; P=.001). CONCLUSION: Knotless, barbed suture may be a viable alternative to standard suture material for laparoscopic closure of the urinary bladder in horses . Further cyclic and in vivo testing should be performed before use in clinical cases. © Copyright 2016 by The American College of Veterinary Surgeons.
Entities: Chemical
Species
Mesh: See more »
Year: 2016
PMID: 27012927 DOI: 10.1111/vsu.12455
Source DB: PubMed Journal: Vet Surg ISSN: 0161-3499 Impact factor: 1.495