Literature DB >> 27011358

Pharmacokinetic profile that reduces nephrotoxicity of gentamicin in a perfused kidney-on-a-chip.

Sejoong Kim1, Sasha Cai LesherPerez, Byoung Choul C Kim, Cameron Yamanishi, Joseph M Labuz, Brendan Leung, Shuichi Takayama.   

Abstract

Nephrotoxicity is often underestimated because renal clearance in animals is higher compared to in humans. This paper aims to illustrate the potential to fill in such pharmacokinetic gaps between animals and humans using a microfluidic kidney model. As an initial demonstration, we compare nephrotoxicity of a drug, administered at the same total dosage, but using different pharmacokinetic regimens. Kidney epithelial cell, cultured under physiological shear stress conditions, are exposed to gentamicin using regimens that mimic the pharmacokinetics of bolus injection or continuous infusion in humans. The perfusion culture utilized is important both for controlling drug exposure and for providing cells with physiological shear stress (1.0 dyn cm(-2)). Compared to static cultures, perfusion culture improves epithelial barrier function. We tested two drug treatment regimens that give the same gentamycin dose over a 24 h period. In one regimen, we mimicked drug clearance profiles for human bolus injection by starting cell exposure at 19.2 mM of gentamicin and reducing the dosage level by half every 2 h over a 24 h period. In the other regimen, we continuously infused gentamicin (3 mM for 24 h). Although junctional protein immunoreactivity was decreased with both regimens, ZO-1 and occludin fluorescence decreased less with the bolus injection mimicking regimen. The bolus injection mimicking regimen also led to less cytotoxicity and allowed the epithelium to maintain low permeability, while continuous infusion led to an increase in cytotoxicity and permeability. These data show that gentamicin disrupts cell-cell junctions, increases membrane permeability, and decreases cell viability particularly with prolonged low-level exposure. Importantly a bolus injection mimicking regimen alleviates much of the nephrotoxicity compared to the continuous infused regimen. In addition to potential relevance to clinical gentamicin administration regimens, the results are important in demonstrating the general potential of using microfluidic cell culture models for pharmacokinetics and toxicity studies.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27011358     DOI: 10.1088/1758-5090/8/1/015021

Source DB:  PubMed          Journal:  Biofabrication        ISSN: 1758-5082            Impact factor:   9.954


  30 in total

Review 1.  Functional and Biomimetic Materials for Engineering of the Three-Dimensional Cell Microenvironment.

Authors:  Guoyou Huang; Fei Li; Xin Zhao; Yufei Ma; Yuhui Li; Min Lin; Guorui Jin; Tian Jian Lu; Guy M Genin; Feng Xu
Journal:  Chem Rev       Date:  2017-10-09       Impact factor: 60.622

2.  In Vitro Generation of Mouse Colon Crypts.

Authors:  Yuli Wang; Dulan B Gunasekara; Peter J Attayek; Mark I Reed; Matthew DiSalvo; Daniel L Nguyen; Johanna S Dutton; Michael S Lebhar; Scott J Bultman; Christopher E Sims; Scott T Magness; Nancy L Allbritton
Journal:  ACS Biomater Sci Eng       Date:  2017-08-29

Review 3.  Nanomedicines for renal disease: current status and future applications.

Authors:  Nazila Kamaly; John C He; Dennis A Ausiello; Omid C Farokhzad
Journal:  Nat Rev Nephrol       Date:  2016-10-31       Impact factor: 28.314

Review 4.  Organs-on-a-Chip: A Fast Track for Engineered Human Tissues in Drug Development.

Authors:  Kacey Ronaldson-Bouchard; Gordana Vunjak-Novakovic
Journal:  Cell Stem Cell       Date:  2018-03-01       Impact factor: 24.633

5.  Drug absorption related nephrotoxicity assessment on an intestine-kidney chip.

Authors:  Zhongyu Li; Wentao Su; Yujuan Zhu; Tingting Tao; Dong Li; Xiaojun Peng; Jianhua Qin
Journal:  Biomicrofluidics       Date:  2017-06-01       Impact factor: 2.800

Review 6.  A Decade of Organs-on-a-Chip Emulating Human Physiology at the Microscale: A Critical Status Report on Progress in Toxicology and Pharmacology.

Authors:  Mario Rothbauer; Barbara E M Bachmann; Christoph Eilenberger; Sebastian R A Kratz; Sarah Spitz; Gregor Höll; Peter Ertl
Journal:  Micromachines (Basel)       Date:  2021-04-21       Impact factor: 2.891

7.  Tissue engineering toward organ-specific regeneration and disease modeling.

Authors:  Christian Mandrycky; Kiet Phong; Ying Zheng
Journal:  MRS Commun       Date:  2017-07-31       Impact factor: 2.566

Review 8.  Liver and Kidney on Chips: Microphysiological Models to Understand Transporter Function.

Authors:  S Y Chang; E J Weber; Kp Van Ness; D L Eaton; E J Kelly
Journal:  Clin Pharmacol Ther       Date:  2016-08-27       Impact factor: 6.875

Review 9.  Organs-on-chips: into the next decade.

Authors:  Lucie A Low; Christine Mummery; Brian R Berridge; Christopher P Austin; Danilo A Tagle
Journal:  Nat Rev Drug Discov       Date:  2020-09-10       Impact factor: 84.694

Review 10.  Kidney-on-a-chip: untapped opportunities.

Authors:  Nureddin Ashammakhi; Katherine Wesseling-Perry; Anwarul Hasan; Elmahdi Elkhammas; Yu Shrike Zhang
Journal:  Kidney Int       Date:  2018-10-23       Impact factor: 10.612

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.