Literature DB >> 27006737

A correlation analysis of Broselow™ Pediatric Emergency Tape-determined pediatric weight with actual pediatric weight in India.

Deepak Geetaprasad Mishra1, Tamorish Kole1, Rahul Nagpal2, Jeffery Paul Smith3.   

Abstract

BACKGROUND: The Broselow™ Pediatric Emergency Tape indicates standardized, pre-calculated medication doses, dose delivery volumes, and equipment sizes using color-coded zones based on height-weight correlations. The present study attempted to provide more evidence on the effectiveness of the Broselow™ Pediatric Emergency Tape by comparing the tape-estimated weights with actual weights. We hypothesized that the Broselow™ Pediatric Emergency Tape would overestimate weights in Indian children aged<10 years, leading to inaccurate dosing and equipment sizing in the emergency setting.
METHODS: This prospective study of pediatric patients aged <10 years who were divided into three groups based on actual body weight: <10 kg, 10-18 kg, and >18 kg. We calculated the percentage difference between the Broselow-predicted weight and the measured weight as a measure of tape bias. Concordant results were those with a mean percent difference within 3%. Standard deviation was measured to determine precision. Accuracy was determined as color-coded zone prediction and measured weight concordance, including the percentage overestimation by 1-2 zones.
RESULTS: The male-to-female ratio of the patients was 1.3:1. Total agreement between color-coding was 63.18% (κ=0.582). The Broselow™ color-coded zone agreement was 74.8% in the <10 kg group, 61.24% in the 10-18 kg group, and 53.42% in the >18 kg group.
CONCLUSIONS: The Broselow™ Pediatric Emergency Tape showed good evidence for being more reliable in children of the <10 kg and 10-18 kg groups. However, as pediatric weight increased, predictive reliability decreased. This raises concerns over the use of the Broselow™ Pediatric Emergency Tape in Indian children because body weight was overestimated in those weighing >18 kg.

Entities:  

Keywords:  Body weights and measures; Child; Developing countries; Emergencies; India

Year:  2016        PMID: 27006737      PMCID: PMC4786497          DOI: 10.5847/wjem.j.1920-8642.2016.01.007

Source DB:  PubMed          Journal:  World J Emerg Med        ISSN: 1920-8642


  20 in total

1.  Can the Broselow tape be used to estimate weight and endotracheal tube size in Korean children?

Authors:  Hye Young Jang; Sang Do Shin; Young Ho Kwak
Journal:  Acad Emerg Med       Date:  2007-03-23       Impact factor: 3.451

2.  The nature of adverse events in hospitalized patients. Results of the Harvard Medical Practice Study II.

Authors:  L L Leape; T A Brennan; N Laird; A G Lawthers; A R Localio; B A Barnes; L Hebert; J P Newhouse; P C Weiler; H Hiatt
Journal:  N Engl J Med       Date:  1991-02-07       Impact factor: 91.245

3.  Internationalizing the Broselow tape: how reliable is weight estimation in Indian children.

Authors:  Naresh Ramarajan; Rajesh Krishnamoorthi; Matthew Strehlow; James Quinn; Swaminatha V Mahadevan
Journal:  Acad Emerg Med       Date:  2008-05       Impact factor: 3.451

4.  Medication errors and adverse drug events in pediatric inpatients.

Authors:  R Kaushal; D W Bates; C Landrigan; K J McKenna; M D Clapp; F Federico; D A Goldmann
Journal:  JAMA       Date:  2001-04-25       Impact factor: 56.272

5.  Tenfold errors in administration of drug doses: a neglected iatrogenic disease in pediatrics.

Authors:  G Koren; Z Barzilay; M Greenwald
Journal:  Pediatrics       Date:  1986-06       Impact factor: 7.124

6.  The accuracy of visual estimation of body weight in the ED.

Authors:  Bradley L Anglemyer; Chris Hernandez; Jane H Brice; Bin Zou
Journal:  Am J Emerg Med       Date:  2004-11       Impact factor: 2.469

7.  Incidence and types of adverse events and negligent care in Utah and Colorado.

Authors:  E J Thomas; D M Studdert; H R Burstin; E J Orav; T Zeena; E J Williams; K M Howard; P C Weiler; T A Brennan
Journal:  Med Care       Date:  2000-03       Impact factor: 2.983

8.  Do the length-based (Broselow) Tape, APLS, Argall and Nelson's formulae accurately estimate weight of Indian children?

Authors:  A Varghese; V K Vasudevan; S Lewin; C K Indumathi; C Dinakar; S D Subha Rao
Journal:  Indian Pediatr       Date:  2006-10       Impact factor: 1.411

9.  Errors by paediatric residents in calculating drug doses.

Authors:  C Rowe; T Koren; G Koren
Journal:  Arch Dis Child       Date:  1998-07       Impact factor: 3.791

10.  Systems analysis of adverse drug events. ADE Prevention Study Group.

Authors:  L L Leape; D W Bates; D J Cullen; J Cooper; H J Demonaco; T Gallivan; R Hallisey; J Ives; N Laird; G Laffel
Journal:  JAMA       Date:  1995-07-05       Impact factor: 56.272

View more
  9 in total

1.  The Accuracy of the Broselow™ Pediatric Emergency Tape for Weight Estimation in an Omani Paediatric Population.

Authors:  Azher A Al-Busaidi; Lakshmanan Jeyaseelan; Hilal M Al-Barwani
Journal:  Sultan Qaboos Univ Med J       Date:  2017-06-20

2.  The RAMA Ped Card: Does it work for actual weight estimation in child patients at the emergency department.

Authors:  Thavinee Trainarongsakul; Pitsucha Sanguanwit; Supawan Rojcharoenchai; Kittisak Sawanyawisuth; Yuwares Sittichanbuncha
Journal:  World J Emerg Med       Date:  2017

3.  Estimating the weight of children in Nepal by Broselow, PAWPER XL and Mercy method.

Authors:  Karun Shrestha; Prakriti Subedi; Oshna Pandey; Likhita Shakya; Kailash Chhetri; Darlene R House
Journal:  World J Emerg Med       Date:  2018

Review 4.  The accuracy of emergency weight estimation systems in children-a systematic review and meta-analysis.

Authors:  Mike Wells; Lara Nicole Goldstein; Alison Bentley
Journal:  Int J Emerg Med       Date:  2017-09-21

5.  Accuracy of Broselow tape in estimating the weight of the child for management of pediatric emergencies in Nepalese population.

Authors:  Pukar K C; Akhilendra Jha; Kamal Ghimire; Roshana Shrestha; Anmol Purna Shrestha
Journal:  Int J Emerg Med       Date:  2020-02-12

6.  Validation of two pediatric resuscitation tapes.

Authors:  Glorilyn Joyce Ong; Elaine Dy
Journal:  J Am Coll Emerg Physicians Open       Date:  2020-09-28

7.  The accuracy of Broselow pediatric emergency tape in estimating body weight of pediatric patients.

Authors:  Amal H ALSulaibikh; Fahad I Al-Ojyan; Khalid N Al-Mulhim; Thabit S Alotaibi; Faisal O Alqurashi; Latifa F Almoaibed; Mohye H ALwahhas; Mohammad A ALjumaan
Journal:  Saudi Med J       Date:  2017-08       Impact factor: 1.484

8.  Predicting endotracheal tube size from length: Evaluation of the Broselow tape in Indian children.

Authors:  Shalini Subramanian; Madhavi Nishtala; Chandrika Yabagodu Ramavakoda; Gaurang Kothari
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2018 Jan-Mar

Review 9.  A systematic review and meta-analysis of the accuracy of weight estimation systems used in paediatric emergency care in developing countries.

Authors:  Mike Wells; Lara Nicole Goldstein; Alison Bentley
Journal:  Afr J Emerg Med       Date:  2017-09-22
  9 in total