| Literature DB >> 27006665 |
James Prah1, Elvis Ofori Ameyaw2, Richmond Afoakwah2, Patrick Fiawoyife3, Ernest Oppong-Danquah3, Johnson Nyarko Boampong2.
Abstract
Most prescribers and patients in Ghana now opt for the relatively expensive artemether/lumefantrine rather than artesunate-amodiaquine due to undesirable side effects in the treatment of uncomplicated malaria. The study sought to determine the existence of substandard and/or counterfeit artemether-lumefantrine tablets and suspension as well as artemether injection on the market in Cape Coast. Six brands of artemether-lumefantrine tablets, two brands of artemether-lumefantrine suspensions, and two brands of artemether injections were purchased from pharmacies in Cape Coast for the study. The mechanical properties of the tablets were evaluated. The samples were then analyzed for the content of active ingredients using High Performance Liquid Chromatography with a variable wavelength detector. None of the samples was found to be counterfeit. However, the artemether content of the samples was variable (93.22%-104.70% of stated content by manufacturer). The lumefantrine content of the artemether/lumefantrine samples was also variable (98.70%-111.87%). Seven of the artemether-lumefantrine brands passed whilst one failed the International Pharmacopoeia content requirements. All brands of artemether injections sampled met the International Pharmacopoeia content requirement. The presence of a substandard artemether-lumefantrine suspension in the market should alert regulatory bodies to be more vigilant and totally flush out counterfeit and substandard drugs from the Ghanaian market.Entities:
Year: 2016 PMID: 27006665 PMCID: PMC4781956 DOI: 10.1155/2016/8602619
Source DB: PubMed Journal: J Trop Med ISSN: 1687-9686
The country of manufacture, formulation, and some mechanical properties of sampled drugs.
| Sample code | Formulation | Country of manufacture | Hardness (kPa) | Friability (%) | Disintegration time (s) |
|---|---|---|---|---|---|
| AL 1 | Tablet | Ghana | 3.4 ± 0.30 | 0.11 | 671 ± 1.8 |
| AL 2 | Tablet | India | 3.6 ± 0.10 | 0.03 | 611 ± 3.4 |
| AL 3 | Tablet | Ghana | 5.3 ± 0.02 | 0.23 | 554 ± 2.2 |
| AL 4 | Tablet | China | 4.2 ± 0.01 | 0.04 | 671 ± 1.6 |
| AL 5 | Tablet | China | 4.2 ± 0.13 | 0.02 | 791 ± 8.4 |
| AL 6 | Tablet | India | 3.7 ± 0.21 | 0.01 | 866 ± 5.2 |
| AL 7 | Suspension | India | — | — | — |
| AL 8 | Suspension | Ghana | — | — | — |
| AT 1 | Injection | India | — | — | — |
| AT 2 | Injection | Ghana | — | — | — |
Uniformity of weight of AL tablets.
| Sample code | Weight of 20 | Average weight/g ( | Standard | Deviation | Deviation by > twice | Inference |
|---|---|---|---|---|---|---|
| AL 1 | 5.0840 | 0.2542 | 0.0009 | 0 | 0 | Passed |
| AL 2 | 6.9960 | 0.3498 | 0.0006 | 0 | 0 | Passed |
| AL 3 | 4.9980 | 0.2499 | 0.0029 | 1 | 0 | Passed |
| AL 4 | 5.8020 | 0.2901 | 0.0008 | 0 | 0 | Passed |
| AL 5 | 19.4360 | 0.9718 | 0.0007 | 0 | 0 | Passed |
| AL 6 | 6.4280 | 0.3214 | 0.0003 | 0 | 0 | Passed |
Weight of samples used in assay.
| Sample code | Weight of sample | Weight of sample |
|---|---|---|
| AL 1 | 0.6355 | 0.2118 |
| AL 2 | 0.8745 | 0.2915 |
| AL 3 | 0.6248 | 0.2083 |
| AL 4 | 0.7253 | 0.2418 |
| AL 5 | 0.6074 | 0.2025 |
| AL 6 | 0.8035 | 0.2678 |
| AL 7 | 13.8330 | 4.6108 |
| AL 8 | 14.190 | 4.7300 |
Percentage content of artemether and lumefantrine in samples.
| Sample code | Stated content of | Actual content of | Percentage content | Stated content of | Actual content of | Percentage content | Inference |
|---|---|---|---|---|---|---|---|
| AL 1 | 20 | 20.44 | 102.18 | 120 | 121.38 | 101.15 | Passed |
| AL 2 | 20 | 20.32 | 101.62 | 120 | 120.83 | 100.69 | Passed |
| AL 3 | 20 | 20.24 | 101.18 | 120 | 120.14 | 100.11 | Passed |
| AL 4 | 20 | 19.55 | 97.74 | 120 | 118.45 | 98.70 | Passed |
| AL 5 | 80 | 78.43 | 98.04 | 140 | 140.51 | 100.36 | Passed |
| AL 6 | 20 | 20.38 | 101.89 | 120 | 123.00 | 102.50 | Passed |
| AL 7 | 20 | 20.37 | 101.84 | 120 | 123.02 | 102.51 | Passed |
| AL 8 | 20 | 20.56 | 102.82 | 120 | 134.24 | 111.87 | Failed |
| AT 1 | 80 | 79.94 | 99.92 | — | — | — | Passed |
| AT 2 | 80 | 78.54 | 98.17 | — | — | — | Passed |