Literature DB >> 27004925

Assessment of Liliequist membrane by 3D-SPACE technique at 3 T.

Oktay Algin1, Mehmet Kılın2, Evrim Ozmen3, Gokhan Ocakoglu4.   

Abstract

INTRODUCTION: Liliequist membrane (LM) is the most important anatomic structure for the success of endoscopic third ventriculostomy (ETV). Identification of this membrane is difficult with conventional MRI techniques. The purpose of this retrospective study is to determine the impact of three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence with variant flip-angle mode (VFAM) in the assessment of LM at 3-T MRI devices.
METHODS: 3D-SPACE with VFAM images were obtained in 445 patients. LM visibility and integrity were scored as 0 (good), 1 (moderate), and 2 (poor) on these images for each parts (sellar, diencephalic, and mesencephalic) and overall of the membrane.
RESULTS: According to the LM overall integrity scores, 11 % (48 cases) of the patients had perforated membrane. According to subsegmental integrity scores, sellar part was completely intact in 63 % of patients, diencephalic segment was completely intact in 60 % of the patients, and mesencephalic segment was completely intact in 95 % of the patients. Visibility scores of the third ventricle inferior wall were significantly higher in the patients with intact LM (p = 0.001). There was not any statistically significant relationship between LM pattern and overall integrity (p = 0.352). LM attachment sites could be detected easier in the patients who had better visibility of third ventricle inferior wall or intact LM (p < 0.001 for both).
CONCLUSION: 3D-SPACE technique is a useful alternative for the evaluation of morphology, integrity, individual variations, topographic relationships, and visibility of LM since it has some advantages including lower SAR values, fewer artifacts, and high-resolution images.

Entities:  

Keywords:  3D-SPACE; CSF; Liliequist’s membrane; MRI; Third ventriculostomy

Mesh:

Year:  2016        PMID: 27004925     DOI: 10.1007/s00234-016-1669-y

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  17 in total

1.  Liliequist membrane: three-dimensional constructive interference in steady state MR imaging.

Authors:  Yasutaka Fushimi; Yukio Miki; Tetsuya Ueba; Mitsunori Kanagaki; Takahiro Takahashi; Akira Yamamoto; Tabassum L Haque; Junya Konishi; Jun A Takahashi; Nobuo Hashimoto; Junji Konishi
Journal:  Radiology       Date:  2003-11       Impact factor: 11.105

2.  The anatomy of the subarachnoid cisterns.

Authors:  B LILIEQUIST
Journal:  Acta radiol       Date:  1956 Jul-Aug       Impact factor: 1.990

3.  Anatomical and histological study of Liliequist's membrane: with emphasis on its nature and lateral attachments.

Authors:  Xi-an Zhang; Song-tao Qi; Guang-long Huang; Hao Long; Jun Fan; Jun-xiang Peng
Journal:  Childs Nerv Syst       Date:  2011-10-02       Impact factor: 1.475

Review 4.  Anatomical variations and neurosurgical significance of Liliequist's membrane.

Authors:  Martin M Mortazavi; Fareed Rizq; Olivia Harmon; Nimer Adeeb; Mehrnoush Gorjian; Nicole Hose; Elham Modammadirad; Pejman Taghavi; Brandon G Rocque; R Shane Tubbs
Journal:  Childs Nerv Syst       Date:  2014-11-14       Impact factor: 1.475

5.  Membranous structures affecting the success of endoscopic third ventriculostomy in adult aqueductus sylvii stenosis.

Authors:  I Anık; S Ceylan; K Koc; Y Anık; V Etus; H Genc
Journal:  Minim Invasive Neurosurg       Date:  2011-06-07

6.  Ultrastructural changes in the Liliequist membrane in the hydrocephalic process and its implications for the endoscopic third ventriculostomy procedure.

Authors:  Volkan Etus; Seyhun Solakoglu; Savas Ceylan
Journal:  Turk Neurosurg       Date:  2011       Impact factor: 1.003

Review 7.  MR imaging of Liliequist's membrane.

Authors:  Yasutaka Fushimi; Yukio Miki; Jun A Takahashi; Ken-Ichiro Kikuta; Nobuo Hashimoto; Takashi Hanakawa; Hidenao Fukuyama; Kaori Togashi
Journal:  Radiat Med       Date:  2006-02

8.  Evaluation of aqueductal stenosis by 3D sampling perfection with application-optimized contrasts using different flip angle evolutions sequence: preliminary results with 3T MR imaging.

Authors:  O Algin; B Turkbey
Journal:  AJNR Am J Neuroradiol       Date:  2011-12-15       Impact factor: 3.825

9.  Third ventriculostomy site as a neuroreceptorial area.

Authors:  Luca Basaldella; Alessandro Fiorindi; Francesco Sammartino; Raffaele De Caro; Pierluigi Longatti
Journal:  Childs Nerv Syst       Date:  2013-10-02       Impact factor: 1.475

10.  Evaluation of hydrocephalus and other cerebrospinal fluid disorders with MRI: An update.

Authors:  Merve Gulbiz Kartal; Oktay Algin
Journal:  Insights Imaging       Date:  2014-06-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.