Literature DB >> 27004668

Reproducibility of gait parameters at different surface inclinations and speeds using an instrumented treadmill system.

Julia F Item-Glatthorn1, Nicola C Casartelli2, Nicola A Maffiuletti3.   

Abstract

Instrumented treadmill systems allow the practical assessment of gait parameters under several walking conditions. Aim of this study was to evaluate the reproducibility of gait parameters at different surface inclinations and walking speeds using an instrumented treadmill system in healthy individuals. A total of 20 subjects (10 women) with a mean age of 31 years were evaluated with an instrumented treadmill system (FDM-T, Zebris Medical GmbH) during two identical test sessions. Spatial (step length, step width, foot rotation), temporal (cadence, single-limb support, step time) and ground reaction force (heel force, toe force, time to heel force, time to toe force) gait parameters were assessed at three treadmill inclinations (level, uphill, downhill) and five speeds (2, 3, 4, 5, 6 km/h). Between-day reproducibility was evaluated with smallest detectable changes for agreement and intraclass correlation coefficients for reliability. Low agreement and reliability were observed for (i) step length, cadence and step time during slow (2 and 3 km/h) and uphill walking and (ii) time to heel force and time to toe force under the majority of walking conditions. The instrumented treadmill system used in this study provided reproducible measurements for the majority of the evaluated spatial, temporal and ground reaction force gait parameters in healthy individuals. The assessment of time to heel/toe force should be however avoided, and particular care should be taken for some spatial (step length) and temporal (cadence and step time) parameters while walking uphill and/or at slow speeds.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Gait; Inclination; Reproducibility; Speed; Treadmill

Mesh:

Year:  2015        PMID: 27004668     DOI: 10.1016/j.gaitpost.2015.12.037

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  7 in total

1.  Multi-joint biomechanics during sloped walking in patients with developmental dysplasia of the hip.

Authors:  Brecca M M Gaffney; Linda R Van Dillen; Jacqueline N Foody; Paige E Burnet; John C Clohisy; Ling Chen; Michael D Harris
Journal:  Clin Biomech (Bristol, Avon)       Date:  2021-03-28       Impact factor: 2.063

2.  Augmenting propulsion demands during split-belt walking increases locomotor adaptation of asymmetric step lengths.

Authors:  Carly J Sombric; Gelsy Torres-Oviedo
Journal:  J Neuroeng Rehabil       Date:  2020-06-03       Impact factor: 4.262

3.  Influence of Treadmill Design on Gait: Does Treadmill Size Affect Muscle Activation Amplitude? A Musculoskeletal Calculation With Individualized Input Parameters of Gait Analysis.

Authors:  Matthias Woiczinski; Carolin Lehner; Thekla Esser; Manuel Kistler; Monica Azqueta; Johannes Leukert; Leandra Bauer; Eduard Kraft
Journal:  Front Neurol       Date:  2022-03-02       Impact factor: 4.003

4.  Differences between Systems Using Optical and Capacitive Sensors in Treadmill-Based Spatiotemporal Analysis of Level and Sloping Gait.

Authors:  Dimitris Mandalidis; Ioannis Kafetzakis
Journal:  Sensors (Basel)       Date:  2022-04-05       Impact factor: 3.576

5.  [Analysis of gait and effectiveness after unicompartmental knee arthroplasty].

Authors:  Peng Hao; Liu Yang; Rui He; Hao Chen; Maolin Sun; Shuainan Liang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-11-15

6.  Gait after Birmingham Hip Resurfacing: an age-matched controlled prospective study.

Authors:  Anatole V Wiik; Rhiannon Lambkin; Justin P Cobb
Journal:  Bone Joint J       Date:  2019-11       Impact factor: 5.082

7.  The impact of reducing the femoral stem length in total hip arthroplasty during gait.

Authors:  Anatole Vilhelm Wiik; Adeel Aqil; Bilal Al-Obaidi; Mads Brevadt; Justin Peter Cobb
Journal:  Arch Orthop Trauma Surg       Date:  2021-03-24       Impact factor: 3.067

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.