Marcello Zappia1, Giovanna Cuomo2,3, Maria Teresa Martino4, Alfonso Reginelli1, Luca Brunese1.
Abstract
The aim of this study was to determine whether foot position could modify power Doppler grading in evaluation of the Achilles enthesis. Eighteen patients with clinical Achilles enthesitis were studied with power Doppler ultrasound (PDUS) in five different positions of the foot: active and passive dorsiflexion, neutral position, active and passive plantar flexion. The Doppler signal was graded in any position and compared with the others. The Doppler signal was higher with the foot in plantar flexion and decreased gradually, sometimes till to disappear, while increasing dorsiflexion. The Doppler signal was always less during the active keeping of the position of the joint, than during the passive. The PDUS examination of the Achilles enthesis should be performed also with the foot in passive plantar flexion, in order not to underestimate the degree of vascularization.Entities:
Keywords: Achilles enthesitis; Power Doppler Ultrasound PDUS; Spondyloarthritis (SpA)
Mesh:
Year: 2016 PMID: 27002715 DOI: 10.1007/s00296-016-3461-z
Source DB: PubMed Journal: Rheumatol Int ISSN: 0172-8172 Impact factor: 2.631