Literature DB >> 27002293

A Porcine Anterior Segment Perfusion and Transduction Model With Direct Visualization of the Trabecular Meshwork.

Ralitsa T Loewen1, Pritha Roy1, Daniel B Park1, Adrianna Jensen1, Gordon Scott1, Devora Cohen-Karni1, Michael P Fautsch2, Joel S Schuman1, Nils A Loewen1.   

Abstract

PURPOSE: To establish a consistent and affordable, high quality porcine anterior segment perfusion and transduction model that allows direct visualization of the trabecular meshwork.
METHODS: Porcine anterior segments were cultured within 2 hours of death by removing lens and uvea and securing in a specially designed petri dish with a thin bottom to allow direct visualization of the trabecular meshwork with minimal distortion. Twenty-two control eyes (CO) with a constant flow rate were compared to eight gravity perfused eyes (COgr, 15 mm Hg). We established gene delivery to the TM using eGFP expressing feline immunodeficiency virus (FIV) vector GINSIN at 108 transducing units (TU) per eye (GINSIN_8, n = 8) and 107 TU (GINSIN_7, n = 8). Expression was assessed for 14 days before histology was obtained.
RESULTS: Pig eyes were a reliable source for consistent and high quality anterior segment cultures with a low failure rate of 12%. Control eyes had an intraocular pressure (IOP) of 15.8 ± 1.9 mm Hg at fixed pump perfusion with 3 μL/min compared to gravity perfused COgr with imputed 3.7 ± 1.6 μL/min. Vector GINSIN_8 eyes experienced a transient posttransduction IOP increase of 44% that resolved at 48 hours; this was not observed in GINSIN_7 eyes. Expression was higher in GINSIN_8 than in GINSIN_7 eyes. Trabecular meshwork architecture was well preserved.
CONCLUSIONS: Compared with previously used human donor eyes, this inexpensive porcine anterior segment perfusion model is of sufficient, repeatable high quality to develop strategies of TM bioengineering. Trabecular meshwork could be observed directly. Despite significant anatomic differences, effects of transduction replicate the main aspects of previously explored human, feline and rodent models.

Entities:  

Mesh:

Year:  2016        PMID: 27002293      PMCID: PMC4811178          DOI: 10.1167/iovs.15-18125

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


The cost and availability of consistently high quality human donor eyes are a significant impediment to research involving both the engineering of aqueous humor outflow and hypothesized trabecular meshwork (TM) stem cells. This is becoming more pertinent as the prevalence of glaucoma continues to rise.[1] In search for readily available model systems, investigators have explored other species. The common house cat has a more diffuse drainage system with a spread out plexus that is not able to provide sufficient outflow resistance even when a feline myocilin mutant that has an aggressive childhood phenotype in humans is overexpressed.[2] Rodent models have the advantage of cost containment in in vivo experimentation and well-developed molecular biology tools. However, while mice and rats share a circular drainage structure similar to the human Schlemm's canal, their lacy TM has only 3 to 10 layers on thin trabeculae. Nonhuman primates have an outflow tract that is nearly indistinguishable from that of humans, but their husbandry is very demanding and expensive. The outflow tract of pig eyes has been described as sharing many similarities with primate eyes that are lacking in other nonprimate eyes.[3] Most notably, it has a relatively large, wedge-shaped TM and circumferential drainage elements that are analogous to discontinuous Schlemm's canal segments,[4] commonly referred to as the angular aqueous plexus.[5] Features include human biochemical glaucoma markers[4] and microphysiological properties such as giant vacuole formation by the endothelium of Schlemm's canal.[3] The recently sequenced genome of Sus scrofa indicates that pigs and humans have a closer genome match than mice and humans[6-8] for instance, which may provide new tools for a porcine glaucoma model. Because of these advantages and the increased interest in using pig eyes as a glaucoma model,[9-11] we sought to develop an ex vivo culture and transduction system based on this species that enables direct observation of the TM and expression of transgenes.

Methods

Feline Immunodeficiency Viral (FIV) Vector Production

A tripartite FIV vector system was used to produce vesicular stomatitis G (VSV-G) pseudotyped lentiviral vectors[12,13] consisting of envelope plasmid pMD.G, packaging plasmid pFP93, and FIV transfer vector GINSIN-encoding enhanced green fluorescent protein (eGFP) and neomycin resistance via an internal ribosomal entry site (IRES).[12] Lentiviral particles were generated using a new, scaled up transient transfection system with polyethylenimine (PEI) as a polycationic, polymeric transfection agent[14] to provide a simplified and stable platform that allows three full harvests from a single transfection. Prior to transfection, 2.5 × 108 293 T cells that were cycling at a high cell division rate were seeded in a large surface culture vessel (Cell Factory 10; Nunc, Naperville, IL, USA) with 2 L of Dulbecco's modified Eagle's medium (DMEM with 4.5% glucose, 4 mM l-glutamine, without phenol red, without sodium pyruvate; #SH30284.02, Hyclone; GE Healthcare Life Sciences, Piscataway, NJ, USA) at 37°C and supplemented with 10% fetal calf serum and penicillin G sodium/streptomycin sulfate (100 units/mL and 100 μg/mL, Pen Strep, Life Technologies, Grand Island, NY, USA). On the day of transfection (day 0), cell cultures with 80% confluency were incubated with a transfection mix. This transfection mix contained 116 μg of VSV-G envelope plasmid pMD-G, 339 micrograms of packaging plasmid pFP93, and 339 micrograms of transfer plasmid GINSIN which were suspended in 18 mL of 37°C reduced, serum-free media (Opti-MEM; Gibco, Thermo Fisher Scientific, Waltham, MA, USA) that had been combined with 3.2 mL of PEI (polyethylenimine, linear; Polysciences, Inc., Warrington, PA, USA), had been vortexed for 10 seconds, and then allowed to stand for 5 minutes at room temperature. This solution was then pipetted into 1.4 L of fresh media which replaced the one present in the cell factory by gently pouring it along the exchange port without disturbing the cell layers. The cell factory was balanced to distribute the media equally between the layers and placed in an incubator. Following an 8-hour incubation at 37°C, the media containing the transfection mix was replaced with fresh media. Expression of EGFP was imaged by fluorescence microscopy to confirm a transfection rate above 80%. On days 2, 4, and 6, the supernatant was collected and replaced with fresh media. Vector particles were pelleted by ultracentrifugation in a large volume rotor (Type 19; Beckman Coulter Life Sciences, Brea, CA, USA), as previously described,[15,16] and titrated 24 hours later by fluorescence-assisted flow cytometry (FACS) analysis on CrFK cells.[17]

Porcine Eye Anterior Segment Perfusion Culture

Porcine eyes were obtained from the local abattoir and processed within approximately 2 hours of death. The eyelids and adnexal structures were excised, eyes dipped into 5% povidone-iodine ophthalmic solution (betadine 5%; Alcon, Fort Worth, TX, USA) for 30 seconds and then transferred into sterile PBS (Dulbecco's PBS; MP Biomedicals, LLC, Santa Ana, CA, USA). In a tissue culture hood, the eyes were hemisected along the equator followed by removal of the vitreous, lens, ciliary body, iris, retina, and choroid. Pigment shedding was avoided by carefully dissecting the choroid off the sclera directly along the equatorial incision in one piece while leaving the vitreous and lens in place as a barrier toward the anterior chamber. The eyes were irrigated with 10 mL PBS to remove pigment and cellular remnants. The anterior segments were then immediately mounted in perfusion chambers connected to a microinfusion pump (PHD 22/2000; Harvard Apparatus, Holliston, MA, USA) and perfused with serum-free media without phenol red (DMEM with penicillin G sodium/streptomycin sulfate [100 units/mL and 100 μg/mL, respectively]) at a constant flow rate of 3 μL/min. Anterior segments were maintained at 37°C in 5% CO2. The intraocular pressure was continuously monitored with pressure transducers (physiological pressure transducer, SP844; MEMSCAP, Skoppum, Norway) and recorded using a software system (LabChart; ADInstruments, Colorado Springs, CO, USA). The perfusion system was calibrated using a pressure transducer tester (Veri-Cal; Utah Medical Products, Midvale, UT, USA). Eyes that experienced a contamination, showed erroneous IOP recordings in the negative pressure range, or readings above 30 mm Hg during the first 24 hours were considered a failure. Such negative IOP recordings were observed for instance when debris blocked the transducer lumen while early high IOP was interpreted as relative TM failure or blockage. Gravity perfused anterior segments (COgr) were similarly processed and mounted in perfusion chambers connected to a gravity flow system and perfused with serum free clear DMEM supplemented with penicillin G sodium and streptomycin sulfate (100 units/mL and 100 μg/mL, respectively). The gravity flow system utilized a fluid column at a constant height of 20.4 cm above perfusion chambers to maintain pressures at 15 mm Hg. Anterior segments were maintained at 37°C in 5% CO2.

Transduction

Porcine anterior segments were allowed to stabilize at a constant flow rate for 48 hours before any manipulation. On day 0, the central infusion and transducer lines were disconnected and a bolus of 1 mL of DMEM with 1 × 108 transducing units (TU) GINSIN was injected at a rate of 1mL/min, displacing the same amount of intracameral volume. Both lines were reconnected and constant flow perfusion resumed.

Direct Visualization of the Trabecular Meshwork

We redesigned established anterior chamber perfusion dishes[13,18] by reducing the thickness of the bottom to approximately one-third and widening the now flatter central mounting hub (Fig. 1). Upon upside-down inversion and 30° tilt, the anterior chamber angle could be visualized directly. There was reduced image distortion compared with regular chambers with a thick bottom. On days 1, 3, 7, and 14, anterior segments mounted as described above were inverted and placed under a stereo dissecting microscope equipped for fluorescent imaging (Olympus SZX16 with GFP filter cube and DP80 monochrome/color camera; Olympus Corp., Center Valley, PA, USA) with continued perfusion. The dish was stabilized at a 30° angle and each quadrant was imaged using an exposure of 100 ms, 1360 × 1024 resolution and 8-bit depth. Expression of eGFP was confirmed by identifying single cells by high magnification fluorescence microscopy.
Figure 1

Perfused porcine anterior segment culture. (A) View of culture dish without cover. (B) View through bottom of inverted dish allows the observation of the TM directly with central in-line and peripheral pressure transducer line. (C) Side view.

Perfused porcine anterior segment culture. (A) View of culture dish without cover. (B) View through bottom of inverted dish allows the observation of the TM directly with central in-line and peripheral pressure transducer line. (C) Side view. The entire circumference was examined and each quadrant photographed with the dissecting microscope. Fluorescence of TM was graded on a scale of 0 to 4 as previously established: grade 0, no detectable fluorescence; grade 1, single fluorescent spots in the TM; grade 2, numerous, nonconfluent fluorescent spots with some confluent areas; grade 3, extensive, mostly confluent, midlevel transduction; grade 4, extensive, high-level, and confluent fluorescence.[19]

Histology

At the conclusion of the experiment, the anterior segments were removed from the perfusion dish, rinsed in PBS, cut into quadrants, and fixed with 4% paraformaldehyde in PBS for a period of 48 hours before being placed in 70% ethanol. One corneoscleral wedge was taken from each quadrant and paraffin embedded for histologic processing. Paraffin-embedded specimens were cut at 6-μm thickness and stained with hematoxylin eosin (H&E). The ratio of transduced to total TM cells was determined as described previously[19] by counting all TM cells in each of four sections per eye (one from each quadrant). The trabecular meshwork was identified and cell counts of 6-μm H&E-stained paraffin sections obtained for two adjacent quadrants in four transduced and nontransduced anterior segments. Photographs of fluorescent TM were taken of each quadrant at each examination and grades determined in a masked manner using a previously established continuous grading scale.[19]

Statistical Analysis

Total TM cells present in random 6-μm sections from above quadrants were determined by counting the labeled and unlabeled cells and calculating the mean value for each quadrant. An unpaired Student's t-test was used for statistical analysis to compare transduced and nontransduced anterior segments. Because of the linear correlation between transduced cells and grades,[19] expression grades were handled as continuous data during the statistical comparison of marker protein accumulation.

Results

Vector production using the scaled up PEI transfection platform yielded 1.19 TU total on first, 7.28 TU on second and 8.08 TU on third harvest with a titer range of approximately 29% at each time point (n = 3). Porcine anterior segment cultures experienced a low culture failure rate of 12%. Control anterior segments (Fig. 2) had an IOP of 15.8 ± 1.9 mm Hg during constant perfusion at a rate of 3 μL/min compared with gravity-perfused control anterior segments with an imputed flow rate of 3.7 ± 1.6 μL/min at constant gravity perfusion with a pressure of 15 mm Hg. Control anterior segments were cultured in the redesigned culture system (Fig. 1) and pilot anterior segments kept for up to 21 days during initial viability testing (data not shown). Trabecular meshwork could be observed directly through the bottom of the inverted dishes (Fig. 1) with best detection of eGFP fluorescence when held at a 30° angle (Fig. 3). View was relatively free of distortion for whole eye and quadrant view at up to ×10 magnification but became vertically compressed when viewed at higher magnification or when held at a steeper angle (Fig. 3C). In anterior segments with extensive transduction, fluorescent TM could be seen over 360° but with segmental focus and short areas of nontransduction (Fig. 3). During observation, the eye remained well pressurized and perfused. The most notable IOP changes occurred when the perfusion system was disconnected for media change (Fig. 4).
Figure 2

Intraocular pressure graph of perfused anterior segment controls (n = 22, left). Representative histology at the experimental endpoint. AP: aqueous plexus. Scale bar: 500 μm.

Figure 3

Direct, repeated visualization of whole eye with view of transduced TM through the bottom of the redesigned perfusion system. Left: Macroscopic view without magnification. Middle: Tenfold magnified view of TM. Translucent outflow port with shadow can be seen. Right: Fifty-fold magnified view of TM with only minor image distortion (TM is 700 μm wide).

Figure 4

Intraocular pressure and directly observed, same eye eGFP expression in TM of eyes transduced with 108 TU of eGFP-expressing FIV vector at time points indicated. Intraocular pressure drop at 48 and 192 hours corresponds to perfusion media exchange. Histology was obtained at the experimental endpoint. Scale bar: 500 μm.

Intraocular pressure graph of perfused anterior segment controls (n = 22, left). Representative histology at the experimental endpoint. AP: aqueous plexus. Scale bar: 500 μm. Direct, repeated visualization of whole eye with view of transduced TM through the bottom of the redesigned perfusion system. Left: Macroscopic view without magnification. Middle: Tenfold magnified view of TM. Translucent outflow port with shadow can be seen. Right: Fifty-fold magnified view of TM with only minor image distortion (TM is 700 μm wide). Intraocular pressure and directly observed, same eye eGFP expression in TM of eyes transduced with 108 TU of eGFP-expressing FIV vector at time points indicated. Intraocular pressure drop at 48 and 192 hours corresponds to perfusion media exchange. Histology was obtained at the experimental endpoint. Scale bar: 500 μm. Within 24 hours of transduction, porcine TM showed low level eGFP marker gene expression after transduction at the highest titer tested, 108 TU (Fig. 4). Expression peaked within 48 hours. At this titer, TM transduction was extensive and could be observed throughout the entire periphery. The culture system enabled us to find precise landmarks during serial observation as in the example of the less transduced, more pigmented TM in the center of the fluorescent band of TM in Figure 5 (Fig. 4, identical quadrant of the same eye is shown in time lapse).
Figure 5

Intraocular pressure and directly observed, same eye eGFP expression in TM of eyes transduced with 107 TU of eGFP-expressing FIV vector at time points indicated. Gaps in IOP recording at 72 and 120 hours correspond to perfusion media exchange. Histology was obtained at the experimental endpoint. Scale bar: 500 μm.

Intraocular pressure and directly observed, same eye eGFP expression in TM of eyes transduced with 107 TU of eGFP-expressing FIV vector at time points indicated. Gaps in IOP recording at 72 and 120 hours correspond to perfusion media exchange. Histology was obtained at the experimental endpoint. Scale bar: 500 μm. Adjacent structures were also occasionally transduced, for instance the sclera (Fig. 3) and corneal endothelium (Fig. 4). Anterior segments of GINSIN transduced with 108 TU experienced a significant (P = 0.03) but transient posttransduction IOP increase of 44% at 24 hours that resolved at 48 hours (Fig. 4) returning 14.4 ± 2.5 mm Hg without being significantly different from controls. Histology obtained at the conclusion of the experiment indicated a well-preserved TM architecture (Fig. 4, inset). At transduction with 107 TU, no significant IOP elevation occurred (Fig. 5). Instead, these anterior segments experienced a small but significant reduction of IOP (P = 0.03) before returning to 14.1 ± 2.4 mm Hg, which was not significantly different from control anterior segments (P = 0.2). Expression was initially faint and could only be observed in some anterior segments (Figs. 4, 5) before increasing. At 24 hours, relative GINSIN expression grading in anterior segments transduced with 108 TU had an average of 0.5 ± 0.7 (P < 0.01) at 24 hours on a scale from 0 to 4 that increased to 2.6 ± 1.1 at 168 hours (P < 0.01). Anterior segments transduced with 107 TU had a significantly lower expression than those transduced with 108 TU. It was 0.2 ± 0.4 at 24 hours which increased to 0.7 ± 1.0 (Fig. 5) at 168 hours. Peaks for both titers were achieved at the same observation time point. Despite weak or absent fluorescence, the new culture chambers allowed to identify anatomic landmarks in serial observation (Fig. 5, example with same anterior segments and same quadrants). Trabecular meshwork architecture was well preserved in these anterior segments (Fig. 5, inset). Trabecular meshwork cell counts were similar between control and transduced anterior segments (Fig. 6, all P > 0.6; Supplementary Fig. S1).
Figure 6

Expression grades of eyes transduced with 107 and 108 TU (left, n = 8 for each group; error bars = SD) and corresponding TM cellularity (right, n = 8 eyes for each group with two sections per eye counted from adjacent quadrants; error bars ± SD).

Expression grades of eyes transduced with 107 and 108 TU (left, n = 8 for each group; error bars = SD) and corresponding TM cellularity (right, n = 8 eyes for each group with two sections per eye counted from adjacent quadrants; error bars ± SD).

Discussion

There are significant supply challenges for human donor eyes in research which is partially due to the increased rate of corneal endothelium and limbal stem cells transplantation. However, a local abattoir can serve as a source of porcine eyes to produce reliable, high quality anterior segment cultures. Compared with human donor eyes that have a wide age range, disease, and variable time from explantation to culture, the consistency of pig eyes resulted in a considerably lower failure rate in our hands.[13,18] Low costs and close correlation with human anatomy make pig eyes an attractive model for research[20,21] and training in ophthalmology.[22,23] The pig's similarity in size and anatomy also led to research into xenotransplantation with a focus on kidney, liver, and cornea[24] and, more recently, the outflow tract.[10] Here, we describe a method to track transgene expression in an ex vivo pig eye culture system by direct observation that is made possible by redesigned, thinner culture dishes. The ability to directly observe the TM from the inside will provide a valuable tool to correlate expression of transgenes in the TM with the resulting segmental outflow changes as measured in quantitative canalograms obtained from the outside (Loewen R, et al. IOVS 2015;56:ARVO E-Abstract 2225846). The intraocular pressure of 15.8 ± 1.9 mm Hg we observed at the normal aqueous flow rate of 3 to 4 μL/min[21,25] is close to the physiologic IOP of 15.2 ± 1.8 mm Hg[26] of pigs and has been used in other porcine ex vivo studies.[27,28] This intraocular pressure, obtained with a perfusion rate of 3 μL/min, matches our imputed outflow of 3.7 ± 1.6 μL/min using the reverse approach of infusing these eyes at 15 mm Hg in our constant pressure experiments.[29] In contrast to these studies, we did not observe any prominent corneal swelling that can occur without a physiological transcorneal pressure gradient that allows proper nutrient transport into the stroma[30] and preservation of normal corneal thickness and contour.[31,32] The short time from enucleation to culture and limited exposure to povidone-iodine may have further reduced corneal compromise. Problems encountered in prior use of pig eyes include pigment release resulting in trabecular meshwork obstruction,[21] the larger diameter that not all human eye culture systems can accommodate, and the more plexus-like, discontinuous segments of Schlemm's canal.[5] The discontinuity of Schlemm's canal may be an advantage for new outflow research strategies concerned with focal TM modification by limiting effects to the immediate downstream drainage system and providing the opportunity for localized flow measurements. Segmental flow has recently been observed in other species as well.[33,34] By dissecting the choroid off the sclera directly along the equatorial incision and using the lens as a barrier toward the anterior chamber, we avoided the complexity of prior protocols meant to reduce pigment shedding.[21] Copious irrigation alone was not sufficient to dislodge pigment that had already made it into the TM. We developed a protocol for scaled-up FIV vector production with PEI transfection that provided reliable high titers eliminating the pH and titer variability of traditional production systems using calcium chloride.[35] Because transfected cell layers remained adherent, the vector could be harvested three times for an entire week with only moderate decline of titers. Feline immunodeficiency virus, a non-primate lentiviral vector that has the safety advantage of not being based on a human pathogen, can transduce primate,[13,18,36] feline,[2,19] and rodent[12] trabecular meshwork at a high level. This observation was principally the same in pig eyes, including a limited and temporary effect on outflow function at the highest titers.[13] Different from prior species, the corneal endothelium and sclera that were in proximity to the TM in pig eyes appeared to be transduced more often. This could be caused by different flow kinetics due to a relatively large anterior chamber with a less selective contact and perfusion of the target tissue. This vector does not currently deploy receptor or transcriptional targeting strategies that may become necessary in cytoablative models.[12] The somewhat lower expression levels compared with human[13] and feline[19] eyes may indicate that lentiviral restriction is present but can be overcome at higher titers. Defense mechanisms to curb lateral intrusion of foreign code from retro-elements are known in many species and the most important restriction factors found in human cells are also present in the pig as a genome search for APOBEC-3F,[37] TRIM5,[38] BST2,[39] SAMHD1,[40] and ZAP[41] demonstrates. Restriction has not presented an obstacle to lentiviral germline transgenesis with HIV and EIAV vectors[42-45] and should not impede future use of these vectors in anterior segments. Relevant to biosafety in TM engineering studies involving xenotransplantation, the pig genome harbors porcine endogenous retroviruses (PERV-A, -B, and -C),[46,47] but these encounter TRIM[48] and APOBEC3[49]-mediated restriction in human cells. In conclusion, we found that pig eyes can be used as a reliable and high quality source for anterior segment perfusion cultures. The trabecular meshwork could be transduced and expression monitored serially. The ability to manipulate and directly observe the TM in this culture system, combined with the relative similarity to human eyes, will provide useful tools for new approaches of bioengineering in glaucoma research.[10,50] Click here for additional data file.
  43 in total

1.  Adenoviral reporter gene transfer to the human trabecular meshwork does not alter aqueous humor outflow. Relevance for potential gene therapy of glaucoma.

Authors:  T Borrás; L L Rowlette; S C Erzurum; D L Epstein
Journal:  Gene Ther       Date:  1999-04       Impact factor: 5.250

2.  FIV Vectors.

Authors:  Nils Loewen; Roman Barraza; Todd Whitwam; Dyana T Saenz; Iris Kemler; Eric M Poeschla
Journal:  Methods Mol Biol       Date:  2003

3.  Pig eye trabeculectomy-a wet-lab teaching model.

Authors:  G A Lee; M Y-M Chiang; P Shah
Journal:  Eye (Lond)       Date:  2006-01       Impact factor: 3.775

4.  Endothelial nitric oxide synthase-related mechanotransduction changes in aged porcine angular aqueous plexus cells.

Authors:  Yuan Lei; William Daniel Stamer; Jihong Wu; Xinghuai Sun
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-11-06       Impact factor: 4.799

5.  A new method for selection of angular aqueous plexus cells from porcine eyes: a model for Schlemm's canal endothelium.

Authors:  Yuan Lei; Darryl R Overby; A Thomas Read; W Daniel Stamer; C Ross Ethier
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-06-16       Impact factor: 4.799

6.  Stem cells from trabecular meshwork home to TM tissue in vivo.

Authors:  Yiqin Du; Hongmin Yun; Enzhi Yang; Joel S Schuman
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-02-19       Impact factor: 4.799

7.  Durable, safe, multi-gene lentiviral vector expression in feline trabecular meshwork.

Authors:  Pranay D Khare; Nils Loewen; Wulin Teo; Román A Barraza; Dyana T Saenz; Douglas H Johnson; Eric M Poeschla
Journal:  Mol Ther       Date:  2007-10-02       Impact factor: 11.454

8.  Contributing factors to corneal deformation in air puff measurements.

Authors:  Sabine Kling; Susana Marcos
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-07-26       Impact factor: 4.799

9.  Mapping molecular differences and extracellular matrix gene expression in segmental outflow pathways of the human ocular trabecular meshwork.

Authors:  Janice A Vranka; John M Bradley; Yong-Feng Yang; Kate E Keller; Ted S Acott
Journal:  PLoS One       Date:  2015-03-31       Impact factor: 3.240

10.  Analyses of pig genomes provide insight into porcine demography and evolution.

Authors:  Martien A M Groenen; Alan L Archibald; Hirohide Uenishi; Christopher K Tuggle; Yasuhiro Takeuchi; Max F Rothschild; Claire Rogel-Gaillard; Chankyu Park; Denis Milan; Hendrik-Jan Megens; Shengting Li; Denis M Larkin; Heebal Kim; Laurent A F Frantz; Mario Caccamo; Hyeonju Ahn; Bronwen L Aken; Anna Anselmo; Christian Anthon; Loretta Auvil; Bouabid Badaoui; Craig W Beattie; Christian Bendixen; Daniel Berman; Frank Blecha; Jonas Blomberg; Lars Bolund; Mirte Bosse; Sara Botti; Zhan Bujie; Megan Bystrom; Boris Capitanu; Denise Carvalho-Silva; Patrick Chardon; Celine Chen; Ryan Cheng; Sang-Haeng Choi; William Chow; Richard C Clark; Christopher Clee; Richard P M A Crooijmans; Harry D Dawson; Patrice Dehais; Fioravante De Sapio; Bert Dibbits; Nizar Drou; Zhi-Qiang Du; Kellye Eversole; João Fadista; Susan Fairley; Thomas Faraut; Geoffrey J Faulkner; Katie E Fowler; Merete Fredholm; Eric Fritz; James G R Gilbert; Elisabetta Giuffra; Jan Gorodkin; Darren K Griffin; Jennifer L Harrow; Alexander Hayward; Kerstin Howe; Zhi-Liang Hu; Sean J Humphray; Toby Hunt; Henrik Hornshøj; Jin-Tae Jeon; Patric Jern; Matthew Jones; Jerzy Jurka; Hiroyuki Kanamori; Ronan Kapetanovic; Jaebum Kim; Jae-Hwan Kim; Kyu-Won Kim; Tae-Hun Kim; Greger Larson; Kyooyeol Lee; Kyung-Tai Lee; Richard Leggett; Harris A Lewin; Yingrui Li; Wansheng Liu; Jane E Loveland; Yao Lu; Joan K Lunney; Jian Ma; Ole Madsen; Katherine Mann; Lucy Matthews; Stuart McLaren; Takeya Morozumi; Michael P Murtaugh; Jitendra Narayan; Dinh Truong Nguyen; Peixiang Ni; Song-Jung Oh; Suneel Onteru; Frank Panitz; Eung-Woo Park; Hong-Seog Park; Geraldine Pascal; Yogesh Paudel; Miguel Perez-Enciso; Ricardo Ramirez-Gonzalez; James M Reecy; Sandra Rodriguez-Zas; Gary A Rohrer; Lauretta Rund; Yongming Sang; Kyle Schachtschneider; Joshua G Schraiber; John Schwartz; Linda Scobie; Carol Scott; Stephen Searle; Bertrand Servin; Bruce R Southey; Goran Sperber; Peter Stadler; Jonathan V Sweedler; Hakim Tafer; Bo Thomsen; Rashmi Wali; Jian Wang; Jun Wang; Simon White; Xun Xu; Martine Yerle; Guojie Zhang; Jianguo Zhang; Jie Zhang; Shuhong Zhao; Jane Rogers; Carol Churcher; Lawrence B Schook
Journal:  Nature       Date:  2012-11-15       Impact factor: 49.962

View more
  18 in total

1.  Outflow facility and extent of angle closure in a porcine model.

Authors:  Ying Hong; Chao Wang; Ralitsa Loewen; Susannah Waxman; Priyal Shah; Si Chen; Hamed Esfandiari; Nils A Loewen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-04-03       Impact factor: 3.117

2.  An ex vivo model of human corneal rim perfusion organ culture.

Authors:  Michael Peng; Tyler J Margetts; Chenna Kesavulu Sugali; Naga Pradeep Rayana; Jiannong Dai; Tasneem P Sharma; Vijay Krishna Raghunathan; Weiming Mao
Journal:  Exp Eye Res       Date:  2021-12-09       Impact factor: 3.467

3.  Trabeculopuncture as a predictive test of distal outflow resistance in canal-based surgery.

Authors:  R Verma-Fuehring; M Dakroub; H Han; J Hillenkamp; N A Loewen
Journal:  Sci Rep       Date:  2022-06-22       Impact factor: 4.996

4.  Outflow enhancement by three different ab interno trabeculectomy procedures in a porcine anterior segment model.

Authors:  Yalong Dang; Chao Wang; Priyal Shah; Susannah Waxman; Ralitsa T Loewen; Ying Hong; Hamed Esfandiari; Nils A Loewen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-05-02       Impact factor: 3.117

5.  RKI-1447, a Rho kinase inhibitor, causes ocular hypotension, actin stress fiber disruption, and increased phagocytosis.

Authors:  Yalong Dang; Chao Wang; Priyal Shah; Susannah Waxman; Ralitsa T Loewen; Nils A Loewen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-11-19       Impact factor: 3.117

Review 6.  Gene transfer to the outflow tract.

Authors:  Yalong Dang; Ralitsa Loewen; Hardik A Parikh; Pritha Roy; Nils A Loewen
Journal:  Exp Eye Res       Date:  2016-04-27       Impact factor: 3.467

7.  Differential Canalograms Detect Outflow Changes from Trabecular Micro-Bypass Stents and Ab Interno Trabeculectomy.

Authors:  Hardik A Parikh; Ralitsa T Loewen; Pritha Roy; Joel S Schuman; Kira L Lathrop; Nils A Loewen
Journal:  Sci Rep       Date:  2016-11-04       Impact factor: 4.379

8.  Rapid learning curve assessment in an ex vivo training system for microincisional glaucoma surgery.

Authors:  Yalong Dang; Susannah Waxman; Chao Wang; Hardik A Parikh; Igor I Bussel; Ralitsa T Loewen; Xiaobo Xia; Kira L Lathrop; Richard A Bilonick; Nils A Loewen
Journal:  Sci Rep       Date:  2017-05-09       Impact factor: 4.379

9.  Freeze-thaw decellularization of the trabecular meshwork in an ex vivo eye perfusion model.

Authors:  Yalong Dang; Susannah Waxman; Chao Wang; Adrianna Jensen; Ralitsa T Loewen; Richard A Bilonick; Nils A Loewen
Journal:  PeerJ       Date:  2017-08-14       Impact factor: 2.984

10.  Quantification of Focal Outflow Enhancement Using Differential Canalograms.

Authors:  Ralitsa T Loewen; Eric N Brown; Gordon Scott; Hardik Parikh; Joel S Schuman; Nils A Loewen
Journal:  Invest Ophthalmol Vis Sci       Date:  2016-05-01       Impact factor: 4.799