PURPOSE: To evaluate the feasibility of a simple estimation for the endolymphatic volume ratio (endolymph volume/total lymph volume = %ELvolume) from an area ratio obtained from only one slice (%EL1slice) or from three slices (%EL3slices). The %ELvolume, calculated from a time-consuming measurement on all magnetic resonance (MR) slices, was compared to the %EL1slice and the %EL3slices.Entities:
Mesh:
Substances:
Year: 2016 PMID: 27001396 PMCID: PMC5608112 DOI: 10.2463/mrms.mp.2015-0175
Source DB: PubMed Journal: Magn Reson Med Sci ISSN: 1347-3182 Impact factor: 2.471
Pulse sequence parameters
| Sequence name | Type | Repetition time (ms) | Echo time (ms) | Inversion time (ms) | Flip angle (degree) | Section thickness/gap (mm) | Pixel size (mm) | Number of slices | Echo train length | Field of view (mm) | Matrix size | Number of excitations | Scan time (min) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| MR cisternography (MRC) | SPACE with restore pulse | 4400 | 544 | NA | 90/ initial 180 decrease to constant 120 | 1/0 | 0.5 × 0.5 | 104 | 173 | 165 × 196 | 324 × 384 | 1.8 | 3 |
| Heavily T2 weighted 3D-FLAIR (PPI) | SPACE with inversion pulse | 9000 | 544 | 2250 | 90/ initial 180 decrease to constant 120 | 1/0 | 0.5 × 0.5 | 104 | 173 | 165 × 196 | 324 × 384 | 4 | 15 |
GRAPPA × 2 for all sequences. All sequences utilize a frequency selective fat suppression pre-pulse. Each three-dimensional slab is set in an identical axial orientation. PPI, positive perilymph image; SPACE, sampling perfection with application-optimized contrasts using different flip angle evolutions.
Fig. 1.An example of the MRC images with the ROI placement for the cochlea (a) and the vestibule (b). The number of slices contoured was 7–9 for the cochlea and 5–7 for the vestibule. These ROIs on the MRC images were copied onto the HYDROPS2-Mi2 images (c). MRC, magnetic resonance cisternography; ROI, region of interest.