Literature DB >> 26996292

Four-dimensional live imaging of hemodynamics in mammalian embryonic heart with Doppler optical coherence tomography.

Shang Wang1, David S Lakomy1, Monica D Garcia1, Andrew L Lopez1, Kirill V Larin1,2,3, Irina V Larina4.   

Abstract

Hemodynamic analysis of the mouse embryonic heart is essential for understanding the functional aspects of early cardiogenesis and advancing the research in congenital heart defects. However, high-resolution imaging of cardiac hemodynamics in mammalian models remains challenging, primarily due to the dynamic nature and deep location of the embryonic heart. Here we report four-dimensional micro-scale imaging of blood flow in the early mouse embryonic heart, enabling time-resolved measurement and analysis of flow velocity throughout the heart tube. Our method uses Doppler optical coherence tomography in live mouse embryo culture, and employs a post-processing synchronization approach to reconstruct three-dimensional data over time at a 100 Hz volume rate. Experiments were performed on live mouse embryos at embryonic day 9.0. Our results show blood flow dynamics inside the beating heart, with the capability for quantitative flow velocity assessment in the primitive atrium, atrioventricular and bulboventricular regions, and bulbus cordis. Combined cardiodynamic and hemodynamic analysis indicates this functional imaging method can be utilized to further investigate the mechanical relationship between blood flow dynamics and cardiac wall movement, bringing new possibilities to study biomechanics in early mammalian cardiogenesis. Four-dimensional live hemodynamic imaging of the mouse embryonic heart at embryonic day 9.0 using Doppler optical coherence tomography, showing directional blood flows in the sinus venosus, primitive atrium, atrioventricular region and vitelline vein.
© 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  Doppler optical coherence tomography; cardiac hemodynamics; live imaging; mouse embryo; retrograde blood flow

Mesh:

Year:  2016        PMID: 26996292      PMCID: PMC5152918          DOI: 10.1002/jbio.201500314

Source DB:  PubMed          Journal:  J Biophotonics        ISSN: 1864-063X            Impact factor:   3.207


  65 in total

1.  Long-term two-photon fluorescence imaging of mammalian embryos without compromising viability.

Authors:  J M Squirrell; D L Wokosin; J G White; B D Bavister
Journal:  Nat Biotechnol       Date:  1999-08       Impact factor: 54.908

Review 2.  Ultrasound biomicroscopy-Doppler in mouse cardiovascular development.

Authors:  Colin K L Phoon; Daniel H Turnbull
Journal:  Physiol Genomics       Date:  2003-06-24       Impact factor: 3.107

3.  Spectral-domain optical coherence phase microscopy for quantitative phase-contrast imaging.

Authors:  Chulmin Joo; Taner Akkin; Barry Cense; Boris H Park; Johannes F de Boer
Journal:  Opt Lett       Date:  2005-08-15       Impact factor: 3.776

4.  Three-dimensional optical coherence tomography of the embryonic murine cardiovascular system.

Authors:  Wei Luo; Daniel L Marks; Tyler S Ralston; Stephen A Boppart
Journal:  J Biomed Opt       Date:  2006 Mar-Apr       Impact factor: 3.170

5.  In vivo spectral domain optical coherence tomography volumetric imaging and spectral Doppler velocimetry of early stage embryonic chicken heart development.

Authors:  A M Davis; F G Rothenberg; N Shepherd; J A Izatt
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2008-12       Impact factor: 2.129

Review 6.  Doppler ultrasound in mice.

Authors:  Jörg Stypmann
Journal:  Echocardiography       Date:  2007-01       Impact factor: 1.724

7.  Live four-dimensional optical coherence tomography reveals embryonic cardiac phenotype in mouse mutant.

Authors:  Andrew L Lopez; Shang Wang; Kirill V Larin; Paul A Overbeek; Irina V Larina
Journal:  J Biomed Opt       Date:  2015       Impact factor: 3.170

8.  Hemodynamics in congenital heart disease.

Authors:  C S Peskin; C Tu
Journal:  Comput Biol Med       Date:  1986       Impact factor: 4.589

9.  Assessment of fetal compromise by Doppler ultrasound investigation of the fetal circulation. Arterial, intracardiac, and venous blood flow velocity studies.

Authors:  K Hecher; S Campbell; P Doyle; K Harrington; K Nicolaides
Journal:  Circulation       Date:  1995-01-01       Impact factor: 29.690

10.  Fully distributed absolute blood flow velocity measurement for middle cerebral arteries using Doppler optical coherence tomography.

Authors:  Li Qi; Jiang Zhu; Aneeka M Hancock; Cuixia Dai; Xuping Zhang; Ron D Frostig; Zhongping Chen
Journal:  Biomed Opt Express       Date:  2016-01-20       Impact factor: 3.732

View more
  15 in total

1.  Embryonic aortic arch hemodynamics are a functional biomarker for ethanol-induced congenital heart defects [Invited].

Authors:  Lindsy M Peterson; Shi Gu; Ganga Karunamuni; Michael W Jenkins; Michiko Watanabe; Andrew M Rollins
Journal:  Biomed Opt Express       Date:  2017-02-24       Impact factor: 3.732

Review 2.  Label-free optical imaging in developmental biology [Invited].

Authors:  Shang Wang; Irina V Larina; Kirill V Larin
Journal:  Biomed Opt Express       Date:  2020-03-13       Impact factor: 3.732

3.  Dynamic imaging and quantitative analysis of cranial neural tube closure in the mouse embryo using optical coherence tomography.

Authors:  Shang Wang; Monica D Garcia; Andrew L Lopez; Paul A Overbeek; Kirill V Larin; Irina V Larina
Journal:  Biomed Opt Express       Date:  2016-12-21       Impact factor: 3.732

4.  Prolonged in vivo functional assessment of the mouse oviduct using optical coherence tomography through a dorsal imaging window.

Authors:  Shang Wang; Riana Syed; Olga A Grishina; Irina V Larina
Journal:  J Biophotonics       Date:  2018-02-08       Impact factor: 3.207

5.  Speckle variance optical coherence tomography of blood flow in the beating mouse embryonic heart.

Authors:  Olga A Grishina; Shang Wang; Irina V Larina
Journal:  J Biophotonics       Date:  2017-04-18       Impact factor: 3.207

6.  Biomechanical assessment of myocardial infarction using optical coherence elastography.

Authors:  Shang Wang; Manmohan Singh; Thuy Tien Tran; John Leach; Salavat R Aglyamov; Irina V Larina; James F Martin; Kirill V Larin
Journal:  Biomed Opt Express       Date:  2018-01-23       Impact factor: 3.732

7.  Multicontrast endomyocardial imaging by single-channel high-resolution cross-polarization optical coherence tomography.

Authors:  Xinwen Yao; Yu Gan; Yuye Ling; Charles C Marboe; Christine P Hendon
Journal:  J Biophotonics       Date:  2018-01-10       Impact factor: 3.207

8.  Complex regression Doppler optical coherence tomography.

Authors:  Sahar Elahi; Shi Gu; Lars Thrane; Andrew Rollins; Michael Jenkins
Journal:  J Biomed Opt       Date:  2018-04       Impact factor: 3.170

9.  Optogenetic cardiac pacing in cultured mouse embryos under imaging guidance.

Authors:  Andrew L Lopez; Shang Wang; Irina V Larina
Journal:  J Biophotonics       Date:  2020-08-18       Impact factor: 3.207

Review 10.  Validating the Paradigm That Biomechanical Forces Regulate Embryonic Cardiovascular Morphogenesis and Are Fundamental in the Etiology of Congenital Heart Disease.

Authors:  Bradley B Keller; William J Kowalski; Joseph P Tinney; Kimimasa Tobita; Norman Hu
Journal:  J Cardiovasc Dev Dis       Date:  2020-06-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.