Literature DB >> 26995639

Mercury determination in urine samples by gold nanostructured screen-printed carbon electrodes after vortex-assisted ionic liquid dispersive liquid-liquid microextraction.

Elena Fernández1, Lorena Vidal2, Agustín Costa-García3, Antonio Canals4.   

Abstract

A novel approach is presented to determine mercury in urine samples, employing vortex-assisted ionic liquid dispersive liquid-liquid microextraction and microvolume back-extraction to prepare samples, and screen-printed electrodes modified with gold nanoparticles for voltammetric analysis. Mercury was extracted directly from non-digested urine samples in a water-immiscible ionic liquid, being back-extracted into an acidic aqueous solution. Subsequently, it was determined using gold nanoparticle-modified screen-printed electrodes. Under optimized microextraction conditions, standard addition calibration was applied to urine samples containing 5, 10 and 15 μg L(-1) of mercury. Standard addition calibration curves using standards between 0 and 20 μg L(-1) gave a high level of linearity with correlation coefficients ranging from 0.990 to 0.999 (N = 5). The limit of detection was empirical and statistically evaluated, obtaining values that ranged from 0.5 to 1.5 μg L(-1), and from 1.1 to 1.3 μg L(-1), respectively, which are significantly lower than the threshold level established by the World Health Organization for normal mercury content in urine (i.e., 10-20 μg L(-1)). A certified reference material (REC-8848/Level II) was analyzed to assess method accuracy finding 87% and 3 μg L(-1) as the recovery (trueness) and standard deviation values, respectively. Finally, the method was used to analyze spiked urine samples, obtaining good agreement between spiked and found concentrations (recovery ranged from 97 to 100%).
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Ionic liquid; Mercury; Screen-printed electrodes; Urine samples; Vortex-assisted dispersive liquid–liquid microextraction

Mesh:

Substances:

Year:  2016        PMID: 26995639     DOI: 10.1016/j.aca.2016.02.028

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  Magnetic dispersive solid-phase extraction using a zeolite-based composite for direct electrochemical determination of lead(II) in urine using screen-printed electrodes.

Authors:  Elena Fernández; Lorena Vidal; Joaquín Silvestre-Albero; Antonio Canals
Journal:  Mikrochim Acta       Date:  2020-01-02       Impact factor: 5.833

Review 2.  Screen-Printed Electrodes Modified with "Green" Metals for Electrochemical Stripping Analysis of Toxic Elements.

Authors:  Anastasios Economou
Journal:  Sensors (Basel)       Date:  2018-03-29       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.