N Palhais1, R Brull2, C Kern1, A Jacot-Guillarmod1, A Charmoy1, A Farron3, E Albrecht4. 1. Department of Anaesthesia. 2. Department of Anaesthesia, Toronto Western Hospital and Women's College Hospital, University of Toronto, Toronto, Canada. 3. Department of Orthopaedic, Lausanne University Hospital, Lausanne, Switzerland. 4. Department of Anaesthesia eric.albrecht@chuv.ch.
Abstract
BACKGROUND:Hemidiaphragmatic paresis after ultrasound-guided interscalene brachial plexus block is reported to occur in up to 100% of patients. We tested the hypothesis that an injection lateral to the brachial plexus sheath reduces the incidence of hemidiaphragmatic paresis compared with a conventional intrafascial injection, while providing similar analgesia. METHODS:Forty ASAI-III patients undergoing elective shoulder and clavicle surgery under general anaesthesia were randomized to receive an ultrasound-guided interscalene brachial plexus block for analgesia, using 20 ml bupivacaine 0.5% with epinephrine 1:200 000 injected either between C5 and C6 within the interscalene groove (conventional intrafascial injection), or 4 mm lateral to the brachial plexus sheath (extrafascial injection). The primary outcome was incidence of hemidiaphragmatic paresis (diaphragmatic excursion reduction >75%), measured by M-mode ultrasonography, before and 30 min after the procedure. Secondary outcomes were forced vital capacity, forced expiratory volume in 1 s, and peak expiratory flow. Additional outcomes included time to first opioid request and pain scores at 24 h postoperatively (numeric rating scale, 0-10). RESULTS: The incidences of hemidiaphragmatic paresis were 90% (95% CI: 68-99%) and 21% (95% CI: 6-46%) in the conventional and extrafascial injection groups, respectively (P<0.0001). Other respiratory outcomes were significantly better preserved in the extrafascial injection group. The mean time to first opioid request was similar between groups (conventional: 802 min [95% CI: 620-984 min]; extrafascial: 973 min [95% CI: 791-1155 min]; P=0.19) as were pain scores at 24 h postoperatively (conventional: 1.6 [95% CI: 0.9-2.2]; extrafascial: 1.6 [95% CI: 0.8-2.4]; P=0.97). CONCLUSIONS:Ultrasound-guided interscalene brachial plexus block with an extrafascial injection reduces the incidence of hemidiaphragmatic paresis and impact on respiratory function while providing similar analgesia, when compared with a conventional injection. CLINICAL TRIAL REGISTRATION: NCT02074397.
RCT Entities:
BACKGROUND:Hemidiaphragmatic paresis after ultrasound-guided interscalene brachial plexus block is reported to occur in up to 100% of patients. We tested the hypothesis that an injection lateral to the brachial plexus sheath reduces the incidence of hemidiaphragmatic paresis compared with a conventional intrafascial injection, while providing similar analgesia. METHODS: Forty ASA I-III patients undergoing elective shoulder and clavicle surgery under general anaesthesia were randomized to receive an ultrasound-guided interscalene brachial plexus block for analgesia, using 20 ml bupivacaine 0.5% with epinephrine 1:200 000 injected either between C5 and C6 within the interscalene groove (conventional intrafascial injection), or 4 mm lateral to the brachial plexus sheath (extrafascial injection). The primary outcome was incidence of hemidiaphragmatic paresis (diaphragmatic excursion reduction >75%), measured by M-mode ultrasonography, before and 30 min after the procedure. Secondary outcomes were forced vital capacity, forced expiratory volume in 1 s, and peak expiratory flow. Additional outcomes included time to first opioid request and pain scores at 24 h postoperatively (numeric rating scale, 0-10). RESULTS: The incidences of hemidiaphragmatic paresis were 90% (95% CI: 68-99%) and 21% (95% CI: 6-46%) in the conventional and extrafascial injection groups, respectively (P<0.0001). Other respiratory outcomes were significantly better preserved in the extrafascial injection group. The mean time to first opioid request was similar between groups (conventional: 802 min [95% CI: 620-984 min]; extrafascial: 973 min [95% CI: 791-1155 min]; P=0.19) as were pain scores at 24 h postoperatively (conventional: 1.6 [95% CI: 0.9-2.2]; extrafascial: 1.6 [95% CI: 0.8-2.4]; P=0.97). CONCLUSIONS: Ultrasound-guided interscalene brachial plexus block with an extrafascial injection reduces the incidence of hemidiaphragmatic paresis and impact on respiratory function while providing similar analgesia, when compared with a conventional injection. CLINICAL TRIAL REGISTRATION: NCT02074397.
Authors: Thomas Mutter; Gabrielle S Logan; Sam Neily; Scott Richardson; Nicole Askin; Marita Monterola; Ahmed Abou-Setta Journal: Can J Anaesth Date: 2022-03-14 Impact factor: 6.713
Authors: Magnus Olofsson; Patrick Taffé; Kyle Robert Kirkham; Frédéric Vauclair; Bénédict Morin; Eric Albrecht Journal: BMC Anesthesiol Date: 2020-04-20 Impact factor: 2.217
Authors: P Oliver-Fornies; J P Ortega Lahuerta; R Gomez Gomez; I Gonzalo Pellicer; L Oliden Gutierrez; J Viñuales Cabeza; L Gallego Ligorit; C E Orellana Melgar Journal: Trials Date: 2021-04-19 Impact factor: 2.279