Literature DB >> 26993855

Minimally invasive percutaneous plate osteosynthesis for distal radius fractures with long-segment metadiaphyseal comminution.

X-M Wei1, Z-Z Sun2, Y-J Rui2, X-J Song2, W-M Jiang3.   

Abstract

INTRODUCTION: Distal radius fractures with both metaphyseal and diaphyseal comminution are commonly encountered injuries due to high-energy trauma. However, effectively treating patients with this disease remains challenging for the surgeon. HYPOTHESIS: The goal of this study was to evaluate the outcomes of minimally invasive percutaneous plate osteosynthesis (MIPPO) technique for distal radius fractures with long-segment metadiaphyseal comminution.
MATERIAL AND METHODS: Nine patients with distal radius fractures involving long-segment metadiaphyseal comminution were treated with MIPPO from June 2011 to May 2012. Radiograph index, the range of motion of the wrist and forearm, grip strength, the Disabilities of the Arm, Shoulder, and Hand (DASH) score were assessed at final follow-up. Additionally, time to bone healing, time to return to work or activity, and postoperative complications were also recorded.
RESULTS: All nine fractures healed by 13±1.3 weeks postoperatively. At an average follow-up of 15.9±3.6 months, the radiographs revealed a mean radial inclination of 18.2±2.7°, a mean volar tilt of 10.7±3.2°, and a radial shortening of 2.3±1.0mm. Nine patients had excellent wrist function according to the DASH score, range of motion, and grip strength. Except one patient experienced delayed healing of the distal incision, no complications occurred. All patients resumed work or activity within 16.2±1.9 weeks. DISCUSSION: Volar MIPPO is a safe and effective surgical treatment method for distal radius fractures with long-segment metadiaphyseal comminution, with few potential complications. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.
Copyright © 2016 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Distal radius fracture; Metadiaphyseal comminution; Minimally invasive plate osteosynthesis; Volar locking compression plate

Mesh:

Year:  2016        PMID: 26993855     DOI: 10.1016/j.otsr.2015.12.024

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  5 in total

1.  Transverse or longitudinal? A survey of volar wrist incision preferences.

Authors:  Benjamin Rui Sheng Siow; Claudia Ren Hwee Tong; Mala Satku; Sreedharan Sechachalam; Chong Jin Yeo
Journal:  Singapore Med J       Date:  2019-09-19       Impact factor: 1.858

2.  Long Volar Plating for Metadiaphyseal Fractures of Distal Radius: Study Comparing Minimally Invasive Plate Osteosynthesis versus Conventional Approach.

Authors:  Emilie Pire; Juan José Hidalgo Diaz; Santiago Salazar Botero; Sybille Facca; Philippe A Liverneaux
Journal:  J Wrist Surg       Date:  2017-03-16

3.  Mini-Invasive Surgery for Distal Radius Fractures: A Double Incision under 12 mm.

Authors:  Elisabete Ribeiro; Gustavo Campanholi; Marcelo Acherboim; Gustavo Mantovani Ruggiero
Journal:  J Wrist Surg       Date:  2020-12-04

4.  Mortality and cause of death in distal radius fracture patients: A longitudinal follow-up study using a national sample cohort.

Authors:  Jung Woo Lee; Yong-Beom Lee; Bong Cheol Kwon; Je-Hyun Yoo; Hyo Geun Choi
Journal:  Medicine (Baltimore)       Date:  2019-12       Impact factor: 1.817

5.  A 3D printed cast for minimally invasive transfer of distal radius osteotomy: a cadaver study.

Authors:  G Caiti; J G G Dobbe; S D Strackee; M H M van Doesburg; G J Strijkers; G J Streekstra
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-01-21       Impact factor: 2.924

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.