Does a new implant design with more physiological kinematics provide better results after knee arthroplasty?

Pablo Sanz-Ruiz1, Esther Carbo-Laso2, Berta Alonso-Polo2, Jose Antonio Matas-Diez2, Javier Vaquero-Martín2.   

Abstract

BACKGROUND: Improved knee kinematics is one of the major goals to obtain better satisfaction after total knee arthroplasty. This study examined whether a guided motion knee design improves functional outcome and satisfaction as compared to a conventional design.
METHODS: In a retrospective manner, from January 2005 to December 2008, patients with two different kinematic TKA designs were enrolled. The 150 patients were divided into two groups: guided motion group (77) with kinematic design (Journey) and control group (73) with no kinematic design (LCS). All the patients had the same surgical technique and postoperative protocols. The functional and radiographic results were interpreted with the Hospital for Special Surgery (HSS) knee score and WOMAC score.
RESULTS: After a mean follow-up of 84.2months, the guided motion group had higher mean postoperative range of motion (p=0.022), functional status in the WOMAC function subscale (p=0.002), but had higher residual pain in the WOMAC pain subscale (p=0.018 and p=0.013) and higher iliotibial band syndrome incidence (6.6% vs 0%; p=0.02). There were no significant differences in HSS score between the two groups. No differences were seen between groups in patient satisfaction in the WOMAC total score (p=0.46) and survival rate.
CONCLUSION: The guided motion design can improve functional status according to WOMAC but not to HSS knee scores. Poorer pain scores and no higher patient satisfaction were observed with this kinematic design.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Guided motion arthroplasty; Knee arthroplasty; Knee kinematic; Patient satisfaction

Mesh:

Year:  2016        PMID: 26993570     DOI: 10.1016/j.knee.2016.02.017

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  3 in total

1.  Catastrophic Failures of the Tibial Post in a Bicruciate Substituting Total Knee Prosthesis.

Authors:  Dominic Marino; Zethariah Zelinski; Daniel Mesko; Jason Cochran
Journal:  Arthroplast Today       Date:  2021-04-15

2.  Short-term safety and effectiveness of a second-generation motion-guided total knee system.

Authors:  Adam I Harris; Tianyi David Luo; Jason E Lang; Branko Kopjar
Journal:  Arthroplast Today       Date:  2018-02-16

3.  Second-generation bi-cruciate stabilized total knee system has a lower reoperation and revision rate than its predecessor.

Authors:  Bernhard Christen; Branko Kopjar
Journal:  Arch Orthop Trauma Surg       Date:  2018-08-25       Impact factor: 3.067

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.