Literature DB >> 26993368

Real-time ultrasound-guided infraclavicular axillary vein cannulation: A prospective study in mechanically ventilated critically ill patients.

Tomasz Czarnik1, Ryszard Gawda2, Jakub Nowotarski3.   

Abstract

PURPOSE: The main purpose of this study was to define the venipuncture and catheterization success rates and early mechanical complication rates of ultrasound-guided infraclavicular axillary vein cannulation.
MATERIALS AND METHODS: We performed in-plane, real-time, ultrasound-guided infraclavicular axillary vein catheterizations under emergency and nonemergency conditions in mechanically ventilated, critically ill patients.
RESULTS: We performed 202 cannulation attempts. One hundred and twenty-six procedures (62.4%) were performed under emergency conditions. The puncture of the axillary vein was successful in 98.5% of patients, and the entire procedure success rate was 95.1% (95% confidence interval, 91.1%-97.6%). For the majority of patients (84.1%; P<.001, exact test), the venipuncture occurred during the first attempt. We noted a 22.4% overall complication rate, and most of the complications were malpositions (13.4%). We observed 8.5% of cases with potentially serious complications (puncture of the axillary artery and needle contact with the brachial plexus) and 1 case (0.5%) of pneumothorax. The puncture of the axillary artery occurred in 5 (2.5%) patients.
CONCLUSIONS: In-plane, real-time, ultrasound-guided, infraclavicular axillary vein cannulation in mechanically ventilated, critically ill patients is a safe and reliable method of central venous cannulation and can be considered to be a reasonable alternative to other central venous catheterization techniques.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Axillary vein; Central venous catheterization; Critical care; Ultrasonography

Mesh:

Year:  2016        PMID: 26993368     DOI: 10.1016/j.jcrc.2016.02.021

Source DB:  PubMed          Journal:  J Crit Care        ISSN: 0883-9441            Impact factor:   3.425


  2 in total

1.  A comparison of longitudinal and transverse approaches to ultrasound-guided axillary vein cannulation by experienced operators.

Authors:  Yi-Zhou He; Ming Zhong; Wei Wu; Jie-Qiong Song; Du-Ming Zhu
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

2.  A comparative study of safety and efficacy of ultrasound-guided infra-clavicular axillary vein cannulation versus ultrasound-guided internal jugular vein cannulation in adult cardiac surgical patients.

Authors:  Prajakta D Shinde; Amish Jasapara; Kishan Bansode; Rohit Bunage; Anvay Mulay; Vijay L Shetty
Journal:  Ann Card Anaesth       Date:  2019 Apr-Jun
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.