Literature DB >> 26992420

Safety of optical coherence tomography in daily practice: a comparison with intravascular ultrasound.

Johannes N van der Sijde1, Antonios Karanasos1, Nienke S van Ditzhuijzen1, Takayuki Okamura2, Robert-Jan van Geuns1, Marco Valgimigli1, Jurgen M R Ligthart1, Karen T Witberg1, Saskia Wemelsfelder1, Jiang Ming Fam1,3, BuChun Zhang1,4, Roberto Diletti1, Peter P de Jaegere1, Nicolas M van Mieghem1, Gijs van Soest1, Felix Zijlstra1, Ron T van Domburg1, Evelyn Regar1.   

Abstract

AIMS: Previous studies have reported the safety and feasibility of both time-domain optical coherence tomography (TD-OCT) and Fourier-domain OCT (FD-OCT) in highly selected patients and clinical settings. However, the generalizability of these data is limited, and data in unselected patient populations reflecting a routine cathlab practice are lacking. We compared safety of intracoronary FD-OCT imaging to intravascular ultrasound (IVUS) imaging in a large real-world series of consecutive patients who underwent invasive imaging during coronary catheterization in our centre. METHODS AND
RESULTS: This is a prospective, single-centre registry of patients scheduled for coronary angiography or intervention undergoing intracoronary imaging with FD-OCT or IVUS between April 2008 and December 2013. Intra-procedural and major in-hospital adverse events that could be possibly related to invasive imaging were registered routinely by the operator as part of our clinical report and prospectively recorded in our database. These events were retrospectively individually adjudicated by an independent safety committee. Between April 2008 and December 2013, 13 418 diagnostic or interventional coronary catheterization procedures were performed. Of these, 1142 procedures used OCT and 2476 procedures used IVUS. Invasive imaging-related complications were rare, did not differ between the two imaging methods (OCT: n = 7, 0.6%; IVUS: n = 12, 0.5%; P = 0.6), and were self-limiting after retrieval of the imaging catheter or easily treatable in the catheterization laboratory. No major adverse events, prolongation of hospital stay, or permanent patient harm was observed.
CONCLUSION: FD-OCT is safe in an unselected and heterogeneous group of patients with varying clinical settings. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2016. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  Adverse events; Intravascular ultrasound; Optical coherence tomography; Safety

Mesh:

Year:  2017        PMID: 26992420     DOI: 10.1093/ehjci/jew037

Source DB:  PubMed          Journal:  Eur Heart J Cardiovasc Imaging        ISSN: 2047-2404            Impact factor:   6.875


  14 in total

1.  Shedding light on the mechanisms of stent thrombosis with optical coherence tomography.

Authors:  Johannes Nicolaas van der Sijde; Evelyn Regar
Journal:  J Thorac Dis       Date:  2016-09       Impact factor: 2.895

Review 2.  Optical Coherence Tomography For the Detection of the Vulnerable Plaque.

Authors:  Konstantinos Toutouzas; Antonios Karanasos; Dimitris Tousoulis
Journal:  Eur Cardiol       Date:  2016-12

3.  Intravascular Optical Coherence Tomography for Neurointerventional Surgery.

Authors:  Matthew J Gounis; Giovanni J Ughi; Miklos Marosfoi; Demetrius K Lopes; David Fiorella; Hiram G Bezerra; Conrad W Liang; Ajit S Puri
Journal:  Stroke       Date:  2018-11-29       Impact factor: 7.914

Review 4.  A Survey on Coronary Atherosclerotic Plaque Tissue Characterization in Intravascular Optical Coherence Tomography.

Authors:  Alberto Boi; Ankush D Jamthikar; Luca Saba; Deep Gupta; Aditya Sharma; Bruno Loi; John R Laird; Narendra N Khanna; Jasjit S Suri
Journal:  Curr Atheroscler Rep       Date:  2018-05-21       Impact factor: 5.113

Review 5.  Optical coherence tomography in coronary atherosclerosis assessment and intervention.

Authors:  Makoto Araki; Seung-Jung Park; Harold L Dauerman; Shiro Uemura; Jung-Sun Kim; Carlo Di Mario; Thomas W Johnson; Giulio Guagliumi; Adnan Kastrati; Michael Joner; Niels Ramsing Holm; Fernando Alfonso; William Wijns; Tom Adriaenssens; Holger Nef; Gilles Rioufol; Nicolas Amabile; Geraud Souteyrand; Nicolas Meneveau; Edouard Gerbaud; Maksymilian P Opolski; Nieves Gonzalo; Guillermo J Tearney; Brett Bouma; Aaron D Aguirre; Gary S Mintz; Gregg W Stone; Christos V Bourantas; Lorenz Räber; Sebastiano Gili; Kyoichi Mizuno; Shigeki Kimura; Toshiro Shinke; Myeong-Ki Hong; Yangsoo Jang; Jin Man Cho; Bryan P Yan; Italo Porto; Giampaolo Niccoli; Rocco A Montone; Vikas Thondapu; Michail I Papafaklis; Lampros K Michalis; Harmony Reynolds; Jacqueline Saw; Peter Libby; Giora Weisz; Mario Iannaccone; Tommaso Gori; Konstantinos Toutouzas; Taishi Yonetsu; Yoshiyasu Minami; Masamichi Takano; O Christopher Raffel; Osamu Kurihara; Tsunenari Soeda; Tomoyo Sugiyama; Hyung Oh Kim; Tetsumin Lee; Takumi Higuma; Akihiro Nakajima; Erika Yamamoto; Krzysztof L Bryniarski; Luca Di Vito; Rocco Vergallo; Francesco Fracassi; Michele Russo; Lena M Seegers; Iris McNulty; Sangjoon Park; Marc Feldman; Javier Escaned; Francesco Prati; Eloisa Arbustini; Fausto J Pinto; Ron Waksman; Hector M Garcia-Garcia; Akiko Maehara; Ziad Ali; Aloke V Finn; Renu Virmani; Annapoorna S Kini; Joost Daemen; Teruyoshi Kume; Kiyoshi Hibi; Atsushi Tanaka; Takashi Akasaka; Takashi Kubo; Satoshi Yasuda; Kevin Croce; Juan F Granada; Amir Lerman; Abhiram Prasad; Evelyn Regar; Yoshihiko Saito; Mullasari Ajit Sankardas; Vijayakumar Subban; Neil J Weissman; Yundai Chen; Bo Yu; Stephen J Nicholls; Peter Barlis; Nick E J West; Armin Arbab-Zadeh; Jong Chul Ye; Jouke Dijkstra; Hang Lee; Jagat Narula; Filippo Crea; Sunao Nakamura; Tsunekazu Kakuta; James Fujimoto; Valentin Fuster; Ik-Kyung Jang
Journal:  Nat Rev Cardiol       Date:  2022-04-21       Impact factor: 49.421

6.  Emerging Technology Update Intravascular Photoacoustic Imaging of Vulnerable Atherosclerotic Plaque.

Authors:  Min Wu; Antonius Fw van der Steen; Evelyn Regar; Gijs van Soest
Journal:  Interv Cardiol       Date:  2016-10

7.  Repeatability Assessment of Intravascular Polarimetry in Patients.

Authors:  Martin Villiger; Kenichiro Otsuka; Antonios Karanasos; Pallavi Doradla; Jian Ren; Norman Lippok; Milen Shishkov; Joost Daemen; Roberto Diletti; Robert-Jan van Geuns; Felix Zijlstra; Jouke Dijkstra; Gijs van Soest; Evelyn Regar; Seemantini K Nadkarni; Brett E Bouma
Journal:  IEEE Trans Med Imaging       Date:  2018-07       Impact factor: 10.048

8.  Renal arteriography with endovascular ultrasound for the management of renal infarction patients.

Authors:  Fabrice Ivanes; Jean Dewaele; Caroline Touboul; Philippe Gatault; Bénédicte Sautenet; Christelle Barbet; Matthias Büchler; Laurent Quilliet; Denis Angoulvant; Jean-Michel Halimi
Journal:  BMC Nephrol       Date:  2020-07-14       Impact factor: 2.388

9.  Endovascular procedures cause transient endothelial injury but do not disrupt mature neointima in Drug Eluting Stents.

Authors:  Anouchska Autar; Aladdin Taha; Richard van Duin; Ilona Krabbendam-Peters; Dirk J Duncker; Felix Zijlstra; Heleen M M van Beusekom
Journal:  Sci Rep       Date:  2020-02-07       Impact factor: 4.379

10.  Coronary Optical Coherence Tomography and Cardiac Magnetic Resonance Imaging to Determine Underlying Causes of Myocardial Infarction With Nonobstructive Coronary Arteries in Women.

Authors:  Harmony R Reynolds; Akiko Maehara; Raymond Y Kwong; Tara Sedlak; Jacqueline Saw; Nathaniel R Smilowitz; Ehtisham Mahmud; Janet Wei; Kevin Marzo; Mitsuaki Matsumura; Ayako Seno; Anais Hausvater; Caitlin Giesler; Nisha Jhalani; Catalin Toma; Bryan Har; Dwithiya Thomas; Laxmi S Mehta; Jeffrey Trost; Puja K Mehta; Bina Ahmed; Kevin R Bainey; Yuhe Xia; Binita Shah; Michael Attubato; Sripal Bangalore; Louai Razzouk; Ziad A Ali; Noel Bairey Merz; Ki Park; Ellen Hada; Hua Zhong; Judith S Hochman
Journal:  Circulation       Date:  2020-11-14       Impact factor: 29.690

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.