Literature DB >> 26990857

Metal Stable Isotope Tagging: Renaissance of Radioimmunoassay for Multiplex and Absolute Quantification of Biomolecules.

Rui Liu1,2, Shixi Zhang1, Chao Wei3, Zhi Xing1, Sichun Zhang1, Xinrong Zhang1.   

Abstract

The unambiguous quantification of biomolecules is of great significance in fundamental biological research as well as practical clinical diagnosis. Due to the lack of a detectable moiety, the direct and highly sensitive quantification of biomolecules is often a "mission impossible". Consequently, tagging strategies to introduce detectable moieties for labeling target biomolecules were invented, which had a long and significant impact on studies of biomolecules in the past decades. For instance, immunoassays have been developed with radioisotope tagging by Yalow and Berson in the late 1950s. The later languishment of this technology can be almost exclusively ascribed to the use of radioactive isotopes, which led to the development of nonradioactive tagging strategy-based assays such as enzyme-linked immunosorbent assay, fluorescent immunoassay, and chemiluminescent and electrochemiluminescent immunoassay. Despite great success, these strategies suffered from drawbacks such as limited spectral window capacity for multiplex detection and inability to provide absolute quantification of biomolecules. After recalling the sequences of tagging strategies, an apparent question is why not use stable isotopes from the start? A reasonable explanation is the lack of reliable means for accurate and precise quantification of stable isotopes at that time. The situation has changed greatly at present, since several atomic mass spectrometric measures for metal stable isotopes have been developed. Among the newly developed techniques, inductively coupled plasma mass spectrometry is an ideal technique to determine metal stable isotope-tagged biomolecules, for its high sensitivity, wide dynamic linear range, and more importantly multiplex and absolute quantification ability. Since the first published report by our group, metal stable isotope tagging has become a revolutionary technique and gained great success in biomolecule quantification. An exciting research highlight in this area is the development and application of the mass cytometer, which fully exploited the multiplexing potential of metal stable isotope tagging. It realized the simultaneous detection of dozens of parameters in single cells, accurate immunophenotyping in cell populations, through modeling of intracellular signaling network and undoubted discrimination of function and connection of cell subsets. Metal stable isotope tagging has great potential applications in hematopoiesis, immunology, stem cells, cancer, and drug screening related research and opened a post-fluorescence era of cytometry. Herein, we review the development of biomolecule quantification using metal stable isotope tagging. Particularly, the power of multiplex and absolute quantification is demonstrated. We address the advantages, applicable situations, and limitations of metal stable isotope tagging strategies and propose suggestions for future developments. The transfer of enzymatic or fluorescent tagging to metal stable isotope tagging may occur in many aspects of biological and clinical practices in the near future, just as the revolution from radioactive isotope tagging to fluorescent tagging happened in the past.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26990857     DOI: 10.1021/acs.accounts.5b00509

Source DB:  PubMed          Journal:  Acc Chem Res        ISSN: 0001-4842            Impact factor:   22.384


  8 in total

Review 1.  Towards high throughput and high information coverage: advanced single-cell mass spectrometric techniques.

Authors:  Shuting Xu; Cheng Yang; Xiuping Yan; Huwei Liu
Journal:  Anal Bioanal Chem       Date:  2021-08-26       Impact factor: 4.142

Review 2.  Highly sensitive and multiplexed mass spectrometric immunoassay techniques and clinical applications.

Authors:  Shuting Xu; Huwei Liu; Yu Bai
Journal:  Anal Bioanal Chem       Date:  2022-02-14       Impact factor: 4.142

3.  Standard-free single magnetic bead evaluation: a stable nanoplatform for prostate disease differentiation.

Authors:  Zili Huang; Xiaobo Xie; Bei Xu; Rui Liu; Jianyu Hu; Yi Lv
Journal:  Chem Sci       Date:  2022-04-29       Impact factor: 9.969

4.  A nonfouling voltammetric immunosensor for the carcinoembryonic antigen based on the use of polyaniline nanowires wrapped with hyaluronic acid.

Authors:  Jiasheng Wang; Ni Hui
Journal:  Mikrochim Acta       Date:  2018-06-16       Impact factor: 5.833

5.  Programming Fluorogenic DNA Probes for Rapid Detection of Steroids.

Authors:  Sasha B Ebrahimi; Devleena Samanta; Benjamin E Partridge; Caroline D Kusmierz; Ho Fung Cheng; Arabela A Grigorescu; Jorge L Chávez; Peter A Mirau; Chad A Mirkin
Journal:  Angew Chem Int Ed Engl       Date:  2021-06-01       Impact factor: 16.823

6.  Single-cell fucosylation breakdown: Switching fucose to europium.

Authors:  Zhen Liu; Yong Liang; Yang Zhou; Fuchun Ge; Xiaowen Yan; Limin Yang; Qiuquan Wang
Journal:  iScience       Date:  2021-04-03

7.  Efficient double-quenching of electrochemiluminescence from CdS:Eu QDs by hemin-graphene-Au nanorods ternary composite for ultrasensitive immunoassay.

Authors:  Jing Liu; Meirong Cui; Hong Zhou; Shusheng Zhang
Journal:  Sci Rep       Date:  2016-07-27       Impact factor: 4.379

8.  Simultaneous determination of gastric cancer biomarkers pepsinogen PGI/PGII using element tagged immunoassay coupled with inductively coupled plasma mass spectrometry detection.

Authors:  Wencan Jiang; Gongwei Sun; Yuqing Zhang; Zhian Hu; Xinyu Wen; Shasha Men; Zhi Xing; Sichun Zhang; Biao Huang; Chengbin Wang
Journal:  J Clin Lab Anal       Date:  2020-03-09       Impact factor: 2.352

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.