Literature DB >> 26988204

Comparison on the use of semi-automated and automated core biopsy needle in ultrasound guided breast biopsy.

R Sridharan1, S M Yunos2, S Aziz2, R I Hussain2, S M Alhabshi2, M P Suria Hayati3, J J Saladina4, M A Zulfiqar2.   

Abstract

OBJECTIVE: The aim of this study was to compare the use of semi-automated (Medax Velox 2; Poggio Rusco, Italy) and automated (Bard Magnum Biopsy Instrument; Covington, GA, USA) core biopsy needles, for ultrasound guided breast biopsy.
MATERIALS AND METHODS: A 14G semi-automatic spring loaded core biopsy needle with a 22-mm-throw (Medax Velox 2; Poggio Rusco, Italy) and 14-gauge automated needle device with a 22-mm-throw biopsy gun (Bard-Magnum Biopsy Instrument, Covington, GA, USA) were used for breast biopsies under ultrasound guidance on alternate months during the study period between July 2009 and May 2011. One hundred and sixty lesions were biopsied and specimens were sent for histological evaluation.
RESULTS: The automated needle obtained a higher number of histology reports at 84% (67/80) as compared with the semiautomated needle at 60% (48/80) (Fisher exact test, p value=0.023). Inadequate samples with the automated needle were much less at 9% (7/60) than with the semiautomated needle at 23% (18/60) (Fisher exact test, p value=0.028). The semi-automated needle showed slightly less fragmented samples. However, the number of fragmented samples with definitive diagnosis was slightly higher with the automated compared with the semiautomated needle, at 16% (13/80) and 13% (10/80) respectively. Compared with histology of 29 lesions that were excised, the semi-automated needle had higher sensitivity (100%) but lower specificity (75%) and accuracy (90%) compared with the automated needle (88% sensitivity, 100% specificity, 95% accuracy).
CONCLUSION: Definitive diagnosis from the study samples slightly favours the use of automated core biopsy needle as compared to semi-automated core biopsy needle.

Entities:  

Year:  2015        PMID: 26988204

Source DB:  PubMed          Journal:  Med J Malaysia        ISSN: 0300-5283


  4 in total

1.  Practical Guidelines for Ultrasound-Guided Core Needle Biopsy of Soft-Tissue Lesions: Transformation from Beginner to Specialist.

Authors:  Sang Yoon Kim; Hye Won Chung; Tack Sun Oh; Jong-Seok Lee
Journal:  Korean J Radiol       Date:  2017-02-07       Impact factor: 3.500

2.  Ultrasound-Guided Percutaneous Core Needle Biopsy of Abdominal Viscera: Tips to Ensure Safe and Effective Biopsy.

Authors:  Jin Woong Kim; Sang Soo Shin
Journal:  Korean J Radiol       Date:  2017-02-07       Impact factor: 3.500

3.  Intraoperative contrast-enhanced ultrasound for intramedullary spinal neoplasms: patient series.

Authors:  Ariana Barkley; Lynn B McGrath; Christoph P Hofstetter
Journal:  J Neurosurg Case Lessons       Date:  2021-02-15

4.  In vitro CT visualization of the biopsy location by filling the core biopsy needle with contrast media.

Authors:  Per Thunswärd; David Eksell; Håkan Ahlström; Anders Magnusson
Journal:  Acta Radiol       Date:  2021-10-22       Impact factor: 1.701

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.