Literature DB >> 26987592

The accuracy of the Edinburgh diplopia diagnostic algorithm.

L Butler1, T Yap1, M Wright1.   

Abstract

PurposeTo assess the diagnostic accuracy of the Edinburgh diplopia diagnostic algorithm.MethodsThis was a prospective study. Details of consecutive patients referred to ophthalmology clinics at Falkirk Community Hospital and Princess Alexandra Eye Pavilion, Edinburgh, with double vision were collected by the clinician first seeing the patient and passed to the investigators. The investigators then assessed the patient using the algorithm. An assessment of the degree of concordance between the 'algorithm assisted' diagnosis and the 'gold standard' diagnosis, made by a consultant ophthalmologist was then carried out. The accuracy of the pre-algorithm diagnosis made by the referrer was also noted.ResultsAll patients referred with diplopia were eligible for inclusion. Fifty-one patients were assessed; six were excluded. The pre-algorithm accuracy of referrers was 24% (10/41). The algorithm assisted diagnosis was correct 82% (37/45) of the time. It correctly diagnosed: cranial nerve (CN) III palsy in 6/6, CN IV palsy in 7/8, CN VI palsy in 12/12, internuclear ophthalmoplegia in 4/4, restrictive myopathy in 4/4, media opacity in 1/1, and blurred vision in 3/3. The algorithm assisted diagnosis was wrong in 18% (8/45) of the patients.ConclusionsThe baseline diagnostic accuracy of non-ophthalmologists rose from 24 to 82% when patients were assessed using the algorithm. The improvement in the diagnostic accuracy resulting from the use of the algorithm would, hopefully, result in more accurate triage of patients with diplopia that are referred to the hospital eye service. We hope we have demonstrated its potential as a learning tool for inexperienced clinicians.

Entities:  

Mesh:

Year:  2016        PMID: 26987592      PMCID: PMC4906455          DOI: 10.1038/eye.2016.44

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  12 in total

Review 1.  Measurement of the clinical and cost-effectiveness of non-invasive diagnostic testing strategies for deep vein thrombosis.

Authors:  S Goodacre; F Sampson; M Stevenson; A Wailoo; A Sutton; S Thomas; T Locker; A Ryan
Journal:  Health Technol Assess       Date:  2006-05       Impact factor: 4.014

2.  Causes and prognosis in 4,278 cases of paralysis of the oculomotor, trochlear, and abducens cranial nerves.

Authors:  B W Richards; F R Jones; B R Younge
Journal:  Am J Ophthalmol       Date:  1992-05-15       Impact factor: 5.258

3.  The accuracy of the Edinburgh visual loss diagnostic algorithm.

Authors:  C Goudie; A Khan; C Lowe; M Wright
Journal:  Eye (Lond)       Date:  2015-08-21       Impact factor: 3.775

4.  Adult hypertropia: a guide to diagnostic evaluation based on review of 300 patients.

Authors:  M A Tamhankar; J H Kim; G-S Ying; N J Volpe
Journal:  Eye (Lond)       Date:  2010-11-05       Impact factor: 3.775

5.  Phased trial of a proven algorithm at a new primary care clinic.

Authors:  J J Christensen-Szalanski; P H Diehr; R W Wood; R K Tompkins
Journal:  Am J Public Health       Date:  1982-01       Impact factor: 9.308

6.  Algorithms and the "art' of medicine.

Authors:  A L Komaroff
Journal:  Am J Public Health       Date:  1982-01       Impact factor: 9.308

7.  Double vision as a presenting symptom in an ophthalmic casualty department.

Authors:  R J Morris
Journal:  Eye (Lond)       Date:  1991       Impact factor: 3.775

8.  The accuracy of the Edinburgh Red Eye Diagnostic Algorithm.

Authors:  H Timlin; L Butler; M Wright
Journal:  Eye (Lond)       Date:  2015-02-20       Impact factor: 3.775

9.  Reliability and validity of an algorithm for the diagnosis of normal cognition, mild cognitive impairment, and dementia: implications for multicenter research studies.

Authors:  Ranjan Duara; David A Loewenstein; Maria Greig; Amarilis Acevedo; Elizabeth Potter; Jason Appel; Ashok Raj; John Schinka; Elizabeth Schofield; Warren Barker; Yougui Wu; Huntington Potter
Journal:  Am J Geriatr Psychiatry       Date:  2010-04       Impact factor: 4.105

10.  Acute-onset diplopia.

Authors:  Una O'Colmain; Claire Gilmour; Caroline J MacEwen
Journal:  Acta Ophthalmol       Date:  2013-02-07       Impact factor: 3.761

View more
  4 in total

1.  The Edinburgh diagnostic algorithms: a freely available validated resource for non-ophthalmologists.

Authors:  C Goudie; L Butler; L M Wright
Journal:  Eye (Lond)       Date:  2016-04-08       Impact factor: 3.775

2.  Diplopia: a unique presentation of recurrence of a salivary gland carcinoma.

Authors:  David Mackinlay; Aaron Stephen James Ferguson; Sharon White; Jaiganesh Manickavasagam
Journal:  BMJ Case Rep       Date:  2019-05-05

3.  Evaluating the Diagnostic Accuracy of a Novel Bayesian Decision-Making Algorithm for Vision Loss.

Authors:  Amy Basilious; Chris N Govas; Alexander M Deans; Pradeepa Yoganathan; Robin M Deans
Journal:  Vision (Basel)       Date:  2022-04-04

4.  Peek Community Eye Health - mHealth system to increase access and efficiency of eye health services in Trans Nzoia County, Kenya: study protocol for a cluster randomised controlled trial.

Authors:  Hillary Rono; Andrew Bastawrous; David Macleod; Emmanuel Wanjala; Stephen Gichuhi; Matthew Burton
Journal:  Trials       Date:  2019-08-14       Impact factor: 2.279

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.